Amber caution · ECAM procedure · free to read

AIR L WING LEAK

An amber caution whose first actions the leak detection normally takes by itself. Here is what the two wing loops decide, which valves the leak detection closes, why the wing anti-ice goes with it, and what the crossbleed selector does at OPEN and SHUT, with the live aircraft at the moment the caution comes on.

Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy

The answer first

What AIR L WING LEAK means

AIR L WING LEAK is an amber caution: both leak detection loops of the left wing have sensed overheating near the hot air ducts, above 124 °C. The leak signal acts by itself: it closes engine 1's bleed valve and, except during an engine start, the APU bleed valve if it is open and, with X BLEED at AUTO, the crossbleed valve.

The ECAM procedure then has engine 1's bleed off, the APU bleed off and the crossbleed shut if they are not already, and the wing anti-ice off, with AVOID ICING CONDITIONS. Pack 1 is left without air and pack 2 carries on alone.

Sources FCOM PRO-ABN-AIR AIR L(R) WING LEAK / FCOM DSC-36-10-50 LEAK DETECTION / FCOM DSC-36-20 OVERHEAD PANEL / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES / FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL

The E/WD at the moment AIR L WING LEAK triggers, drawn by the platform's ECAM engine: the amber caution title and the lines it shows
The E/WD at the alertAs our ECAM draws it in the cruise, APU off: the procedure in one version, for some aircraft, whose first line reads IF NOT AUTOMATICALLY CLOSED; another version, for others, reads ENG BLEED (AFFECTED) OFF. The APU BLEED and WING ANTI-ICE lines are left out, both already off; the FCOM says an action line clears once the crew has performed the action. The X BLEED (IF NOT CLOSED) SHUT line is drawn although the leak detection has already closed the valve: a choice of the drawing, as the FCOM does not say whether the line shows then.

At a glance

Level
Amber caution, level 2: single chime, MASTER CAUT steady amber and, normally, the BLEED page on the SD
Sets it off
Both wing bleed leak detection loops of one wing detect a temperature above 124 °C
Closes by itself
The bleed valve on that side; except during an engine start, the crossbleed valve with X BLEED at AUTO and, for a left wing leak, an open APU bleed valve
Lights
FAULT in amber in the ENG BLEED pushbutton of the leaking side, on the AIR COND panel
Lost
The affected side's wing anti-ice valve closes: AVOID ICING CONDITIONS, and STATUS lists WING A.ICE, the engine bleed and the pack of that side

Sources FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-30 ATTENTION GETTERS / FCOM DSC-31-20 SYSTEM PAGES / FCOM PRO-ABN-AIR AIR L(R) WING LEAK / FCOM DSC-36-10-50 LEAK DETECTION / FCOM DSC-36-20 OVERHEAD PANEL / FCOM DSC-30-20-10 DESCRIPTION / FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES

What makes the leak caution come on?

Leak detection loops watch for overheating near the hot air ducts in the fuselage, the pylons and the wings. Each wing has a double loop, A and B. The two Bleed Monitoring Computers, BMC 1 and BMC 2, each hold identical control logic for the system.

A wing leak signal needs both wing loops to detect the leak, or one loop to detect it while the other is inoperative. The caution's own trigger, as the procedure prints it, is both loops of a wing above 124 °C.

If both loops of one wing are inoperative, the crew gets another alert instead, AIR L WNG LEAK DET FAULT, whose STATUS lists L WNG LK DET.

If one BMC fails, the other still issues the wing leak warning, but the associated bleed valve no longer closes automatically; on the A319ceo and A320ceo, the associated FAULT light is lost too.

Sources FCOM DSC-36-10-50 LEAK DETECTION / FCOM PRO-ABN-AIR AIR L(R) WING LEAK / FCOM PRO-ABN-AIR AIR L(R) WNG LEAK DET FAULT / FCOM PRO-ABN-AIR AIR / FCOM DSC-36-10-60 BMC FAILURE

From the wing loops to the valves

From the wing loops to the valvesLoop A and loop B in the left wing feed the BMCs. Their wing leak signal brings up AIR L WING LEAK on the E/WD and lights FAULT in ENG 1 BLEED, and closes engine 1's bleed valve and, except during an engine start, the crossbleed valve with X BLEED at AUTO and, for the left wing, the APU bleed valve if it is open. LOOP Aleft wingLOOP Bleft wingBMC 1 + 2wing leak signalAIR L WING LEAKE/WD, amberFAULTENG 1 BLEED pbBLEED VALVE 1closesCROSSBLEEDcloses at AUTOAPU BLEED VALVEcloses if open
Both loops (or one, with the other inoperative) make the wing leak signal; the BMCs close engine 1's bleed valve and, except during an engine start, the crossbleed valve at AUTO and an open APU bleed valve.

What does the crew see when it comes on?

A level 2 caution: a single chime, MASTER CAUT steady amber, the caution in amber on the E/WD, and normally the BLEED page called up on the SD, the relevant system page.

On the AIR COND panel, FAULT lights amber in ENG 1 BLEED: a wing leak on the related side is one of the light's causes. With the leak present, the ENG BLEED pushbutton cannot open its valve: one condition for opening is no onside wing or pylon leak.

Sources FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-30 ATTENTION GETTERS / FCOM DSC-31-20 SYSTEM PAGES / FCOM DSC-36-20 OVERHEAD PANEL

Live aircraft

The moment the caution comes on

The cruise at FL 350, both engine bleeds on, X BLEED at AUTO, the APU off and the wing anti-ice off. Press the button to start the leak, then look at the E/WD, the BLEED page, the AIR COND panel and the schematic.

The E/WD as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
The system's schematic as the live aircraft starts, drawn by the platform's systems model

The alert Leak hot air in the left wing

The E/WD shows the caution in amber with its lines, X BLEED (IF NOT CLOSED) SHUT among them although the valve is closed (see the E/WD caption). On the panel FAULT lights in ENG 1 BLEED, and engine 1's bleed valve is shut, though ENG 1 BLEED is still at ON: the leak signal closed it. The crossbleed valve, at AUTO with no APU bleed, was closed already and stays closed.

With nothing upstream, pack 1's flow control valve is closed: it does not open with upstream pressure below minimum. Pack 2 runs alone, and in single pack operation HI flow is selected automatically.

Sources FCOM DSC-36-10-50 LEAK DETECTION / FCOM DSC-36-20 OVERHEAD PANEL / FCOM PRO-ABN-AIR AIR / FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL

Work this failure in the ECAM Trainer

Why is the wing anti-ice lost?

The wing anti-ice uses hot air from the pneumatic system to heat slats 3, 4 and 5 of each wing, through one valve in each wing. If the system detects a leak, the affected side's wing anti-ice valve closes automatically. One WING pushbutton commands both sides at once.

The procedure has WING ANTI-ICE OFF and ends with AVOID ICING CONDITIONS, and STATUS adds, if severe ice builds up anyway, a minimum speed of VLS + 10 or green dot, manoeuvring with care and the landing distance procedure.

Sources FCOM DSC-30-20-10 DESCRIPTION / FCOM DSC-30-20-20 OVERHEAD PANEL / FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES

Live aircraft

Try the wing anti-ice with the leak

The left wing is leaking and the leak detection has closed engine 1's bleed valve. Engine 2 still feeds the right side. Predict first, then press WING on the ANTI ICE panel and watch the BLEED page.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
The system's schematic as the live aircraft starts, drawn by the platform's systems model
  1. Predict One WING pushbutton commands both wings. What happens when it goes ON with the left wing leaking?

    Try it Press WING on the ANTI ICE panel.

    Here the right wing's valve opens on engine 2's air, and the BLEED page shows its arrow on that side only. The left valve stays closed, and the pushbutton's FAULT light comes on amber: one of its causes is a valve that is not in the required position.

    This is a limit of the drawing: the FCOM's WING A.ICE SYS FAULT triggers when the pushbutton is ON and one wing valve remains closed, as here, and the FCOM brings a caution with the FAULT light. The live aircraft lights FAULT but raises no WING A.ICE SYS FAULT.

    Sources FCOM DSC-30-20-10 DESCRIPTION / FCOM DSC-30-20-20 OVERHEAD PANEL / FCOM PRO-ABN-W_A_ICE WING A.ICE SYS FAULT

What does the crossbleed selector do with the leak?

The crossbleed valve has two electric motors, one for the automatic mode and one for manual. In automatic mode it opens when the system uses APU bleed air and closes if the system detects an air leak, except during an engine start.

The selector's three positions: at AUTO the valve is open if the APU bleed valve is open, and closed if the APU bleed valve is closed or on a wing, pylon or APU leak, except during an engine start; at OPEN the valve is open; at SHUT it is closed. In the selector's description the closure on a leak is given for AUTO only, and the procedure's line, if the valve has not closed, is X BLEED SHUT.

Sources FCOM DSC-36-10-40 GENERAL / FCOM DSC-36-20 OVERHEAD PANEL / FCOM PRO-ABN-AIR AIR

Live aircraft

Turn the selector with the leak

The same leak: engine 1's bleed valve and the crossbleed valve are closed, pack 1 has no air. Predict, then turn X BLEED, and watch which side engine 2 now feeds.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The system's schematic as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
  1. Predict The leak is still there. What does the crossbleed valve do if X BLEED goes to OPEN?

    Try it Turn X BLEED to OPEN.

    The valve opens and engine 2's air reaches the left side again, pack 1 included, and with it the leaking duct. On some aircraft the FCOM has a red warning for this case, AIR BLEED LEAK, when a leak is detected in a bleed duct and the X BLEED selector is at OPEN.

    Sources FCOM DSC-36-20 OVERHEAD PANEL / FCOM DSC-36-10-40 GENERAL / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES / FCOM PRO-ABN-AIR AIR BLEED LEAK

  2. Try it Turn X BLEED to SHUT.

    At SHUT the crossbleed valve is closed, and pack 1 is without air once more.

    Sources FCOM DSC-36-20 OVERHEAD PANEL

What does the procedure ask of valves the leak may have closed?

Several of the procedure's lines are conditional: ENG 1 BLEED off where the valve has not closed automatically (in one version, for some aircraft), APU BLEED off if not closed, X BLEED SHUT if not closed. The leak signal normally closes these valves by itself, the APU bleed valve if open and the crossbleed valve at AUTO, except during an engine start; each line applies only where it has not.

Setting ENG 1 BLEED to OFF closes the bleed valve and the HP valve, and on the A320neo and A321neo the fan air valve too.

The procedure adds that with the pushbutton ON the FAULT light remains on, and with it OFF the light goes off when the overheat disappears. The ECAM Trainer puts the light out as soon as the pushbutton goes OFF: a simplification of the drawing.

The APU line sits under the condition that the leak is in the left wing. Beside it, the leak logic: a wing leak closes the APU bleed valve only when the leak concerns the left wing, and one condition for the APU BLEED pushbutton to open its valve is no leak in the APU or in the left side bleed.

Sources FCOM PRO-ABN-AIR AIR / FCOM DSC-36-10-50 LEAK DETECTION / FCOM DSC-36-20 OVERHEAD PANEL / FCOM DSC-36-10-30 GENERAL

The air left after the leak

The air left after the leakEngine 1's bleed valve is closed and the crossbleed valve shut, so pack 1 and the left wing anti-ice have no air. Engine 2 feeds pack 2, which runs at HI flow in single pack operation. ENG 1 BLEEDclosedX BLEEDshutENG 2 BLEEDopenPACK 1, L WING A.ICEno airPACK 2alone, HI flow
Engine 1's bleed and the crossbleed shut, the APU off: the left side has no air. Pack 2 runs alone on engine 2, and the left wing anti-ice is lost.

What is lost afterwards?

The STATUS page after AIR L WING LEAK, drawn by the platform's ECAM engine
STATUSOnce the crew has cleared the alerts, as our ECAM draws it.

STATUS is the aircraft's operational summary. Here it starts with AVOID ICING CONDITIONS, then, if severe ice accretion, a minimum speed of VLS + 10 or green dot, manoeuvring with care and the landing distance procedure.

INOP SYS lists WING A.ICE, ENG 1 BLEED and PACK 1 in amber. The FCOM prints one STATUS for this caution, applicable to all aircraft, and the STATUS above shows it.

Sources FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES / FCOM DSC-31-20 STATUS PAGE

A319ceo, A320ceo, A320neo, A321neo: what differs?

A319ceo, A320ceoA320neo, A321neo
The caution and its triggerThe same in every versionThe same in every version
The procedure's first lineNot given by type: one version, for some aircraft, reads ENG BLEED (AFFECTED, IF NOT AUTOMATICALLY CLOSED) OFFNot given by type: another version, for others, reads ENG BLEED (AFFECTED) OFF; the rest is the same
Leak detection loopsA319ceo and A320ceo: a double loop in each wing, a single loop for each pylon and the APUA320neo and A321neo: a double loop in each wing and each pylon, a single loop for the APU
One BMC failedThe other BMC issues the overpressure, overtemperature and wing leak warningsThe other BMC takes over control and monitoring and issues the overpressure and wing leak warnings; the associated overtemperature protection is lost
STATUSThe same in every versionThe same in every version

The ECAM Trainer draws the first version of the procedure in one of its two drawings and the second in the other. The FCOM gives each to a list of aircraft, not to a type.

Sources FCOM PRO-ABN-AIR AIR L(R) WING LEAK / FCOM PRO-ABN-AIR AIR / FCOM DSC-36-10-50 LEAK DETECTION / FCOM DSC-36-10-60 BMC FAILURE / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES

In the ECAM Trainer · A320 Knowledge+

Work AIR L WING LEAK as a crew

Read and do each line against the FCOM, with the E/WD, the SD page and the overhead following your hands, the PF and PM calls, and a debrief that says what you missed.

Work this failure in the ECAM Trainer

Go further

Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The E/WD, the STATUS and the live aircraft are the platform's own ECAM and systems model, the same the ECAM Trainer and the flight deck run. This page explains the procedure; it is not the procedure. Aircraft differ by type, engine and options: your aircraft's FCOM, your QRH and your operator's procedures always come first. How we write and check these pages.

Work it as a crew

Every ECAM procedure, line by line, against the FCOM.

The ECAM Trainer works 108 scenarios with the E/WD, the SD page and the overhead following your hands. Start free today, or open everything with A320 Knowledge+.

For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.