In short
The A320's pneumatic system supplies high pressure air for air conditioning, engine starting, wing anti-icing and more, from three sources: two engine bleed systems, the APU load compressor and an HP ground connection.
- Each engine bleeds its compressor's IP stage, or the HP stage at low engine speed; the bleed valve regulates its pressure, the precooler cools it to about 200 °C.
- A crossbleed valve keeps the two sides apart or joins them; at AUTO it follows the APU bleed valve and closes on a leak, except during engine start.
- The APU bleed opens the crossbleed valve and closes the engine bleeds (X BLEED at AUTO).
- Two Bleed Monitoring Computers (BMC) close a bleed valve themselves on overpressure, overheat or a leak.
- One engine bleed lost: the crossbleed lets the other engine supply both sides. Both lost: no packs, no wing anti-ice; unless the left side leaks, the APU bleed can restore pressurisation at or below FL 200.
Sources FCOM DSC-36-10-10 GENERAL / FCOM DSC-36-10-20 GENERAL / FCOM DSC-36-10-20 AIR BLEED SELECTION / FCOM DSC-36-10-20 PRESSURE REGULATION AND LIMITATION / FCOM DSC-36-10-20 TEMPERATURE REGULATION AND LIMITATION / FCOM DSC-36-10-30 GENERAL / FCOM DSC-36-10-50 LEAK DETECTION / FCOM DSC-36-20 OVERHEAD PANEL / FCOM PRO-ABN-AIR / FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES

Why does the A320 need bleed air at all?
The pneumatic system supplies high pressure air for the air conditioning, for engine starting and for wing anti-icing. It also pressurises the water system and the hydraulic reservoirs, and the FCOM's list adds forward and aft cargo heating and the fuel tank inerting system (FTIS).
That air comes from three places: the two engine bleed systems, the APU's load compressor, and an HP ground connection.
Sources FCOM DSC-36-10-10 GENERAL
What the bleed air is for
What is the simplest way to picture it?
Engine 1 supplies the left side, engine 2 the right, and a crossbleed duct runs between them with one valve on it, the crossbleed valve. Closed, it keeps the two sides isolated; open, it interconnects them.
In the FCOM's drawing, pack 1 and the left wing's anti-ice sit on the engine 1 side, pack 2 and the right wing's on the engine 2 side, and its procedures pair them the same way: the pack an engine 1(2) bleed fault calls affected is pack 1(2), and a left (right) wing leak puts engine 1(2)'s bleed and pack 1(2) on the INOP SYS list.
Two Bleed Monitoring Computers, BMC 1 and BMC 2, control and monitor it all with the overhead panel and the ECAM, and a leak detection system watches for overheating near the hot air ducts.
Sources FCOM DSC-36-10-10 GENERAL / FCOM DSC-36-10-40 GENERAL / FCOM DSC-36-10-20 ARCHITECTURE / FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES / FCOM PRO-ABN-AIR AIR L(R) WING LEAK
Step 1: two sides, one crossbleed valve
Where does an engine's bleed air come from?
From the engine's high pressure compressor, at one of two ports. Normally the air is bled from the intermediate pressure (IP) stage, to keep the fuel penalty low. At low engine speed, when the IP air's pressure and temperature are too low, the system bleeds from the high pressure (HP) stage through the HP valve, and a check valve downstream of the IP port stops HP air flowing back into the IP stage.
Next comes the bleed valve, downstream of the junction of the IP and HP ducts. It is both a shut off valve and a pressure regulating valve: 45 ± 5 PSI on the A319ceo and A320ceo; on the A320neo and A321neo 42 ± 3 PSI with both bleeds and 50 ± 3 PSI with one. If the regulation fails, an overpressure valve closes.
Several things close the bleed valve fully. Pneumatically, on low upstream pressure or return flow. Electrically, when the ENG BLEED pushbutton is OFF, when the ENG FIRE pushbutton is pushed, and when the BMC detects, among other cases, an overtemperature, an overpressure, a leak, an open starter valve or the APU bleed ON. When it is closed electrically, the HP valve closes too.
Last, the precooler: an air to air heat exchanger, cooled by air from the engine's fan, that regulates the bleed air to about 200 °C (on the A320neo and A321neo, 160 °C in the climb or hold with both engine bleeds and no wing anti-ice). The fan air valve controls the fan air, and a spring keeps it closed without pressure.
Sources FCOM DSC-36-10-20 AIR BLEED SELECTION / FCOM DSC-36-10-20 PRESSURE REGULATION AND LIMITATION / FCOM DSC-36-10-20 TEMPERATURE REGULATION AND LIMITATION
Step 2: inside one engine bleed
Switch an engine bleed off
The live aircraft is an A320ceo in the cruise at FL 350, the APU off, both engine bleeds on and X BLEED at AUTO. The AIR COND panel below works: every press changes the schematic above it.


-
Predict With X BLEED at AUTO and no APU bleed, does pack 1 still get air if ENG 1 BLEED goes off?
Try it Switch ENG 1 BLEED off.
OFF closes the bleed valve and the HP valve. At AUTO the crossbleed valve is closed while the APU bleed valve is closed, so nothing reaches the left side: pack 1 has no air.
Sources FCOM DSC-36-20 OVERHEAD PANEL
-
Try it Switch ENG 1 BLEED back on.
The bleed valve opens again: there is upstream pressure, the APU bleed is off, and nothing has been detected.
Sources FCOM DSC-36-20 OVERHEAD PANEL
What do the APU and the ground connection add?
The APU's load compressor supplies air on the ground and in flight, through the APU bleed valve: a shut off valve worked by the APU BLEED pushbutton on the AIR COND panel.
With APU BLEED ON and the APU above 95 %, APU air supplies the pneumatic system, the crossbleed valve opens (at AUTO) and the engine bleed valves close, automatically. One exception: with the crossbleed valve SHUT, engine 2's bleed valve remains open.
The APU bleed has limits: up to 20 000 ft to assist an engine start, and for air conditioning and pressurisation up to 22 500 ft with one pack or 15 000 ft with two. It is not permitted for wing anti-ice.
The third source is the HP ground connection. On the ground only, the BLEED page shows GND when the HP ground air supply can be connected. The crew must not use APU bleed air and an HP air start unit at the same time.
Sources FCOM DSC-36-10-30 GENERAL / FCOM DSC-36-10-20 PRESSURE REGULATION AND LIMITATION / FCOM DSC-36-20 OVERHEAD PANEL / FCOM LIM-APU AUXILIARY POWER UNIT / FCOM DSC-36-10-10 GENERAL / FCOM DSC-36-20 ECAM BLEED PAGE / FCOM LIM-AIR APU BLEED USE WITH HP AIR START UNIT
Step 3: the APU joins the duct
The APU bleed and the crossbleed
On the ground, both engines just started, APU BLEED still ON and X BLEED at AUTO: the BLEED page shows the crossbleed valve open and both engine bleed valves closed.


-
Predict With APU BLEED still ON, what happens if X BLEED goes to SHUT?
Try it Turn X BLEED to SHUT.
The FCOM's exception: with APU BLEED ON and the crossbleed valve SHUT, engine 2's bleed valve remains open. Here the APU supplies the left side and engine 2 the right.
Sources FCOM DSC-36-10-20 PRESSURE REGULATION AND LIMITATION
-
Try it Turn X BLEED back to AUTO.
At AUTO the crossbleed valve is open again, since the APU bleed valve is open, and engine 2's bleed valve closes.
Sources FCOM DSC-36-20 OVERHEAD PANEL / FCOM DSC-36-10-30 GENERAL
-
Predict Now APU BLEED goes off. What do the crossbleed and engine bleed valves do?
Try it Switch APU BLEED off.
At AUTO the crossbleed valve closes with the APU bleed valve, and with the APU bleed off the engine bleed valves can open: each side is back on its own engine.
Sources FCOM DSC-36-20 OVERHEAD PANEL
When do the two sides join?
The crossbleed valve isolates or interconnects the two engines' air supply. The X BLEED rotary selector on the AIR COND panel controls it electrically, through two electric motors: one for automatic mode, one for manual.
At AUTO the valve follows the APU bleed valve: open when it is open, closed when it is closed. It also closes on a wing, pylon or APU leak, except during engine start. OPEN opens it and SHUT closes it.
So in normal flight, with the APU bleed off, the crossbleed valve is closed and each engine supplies its own side; the engine bleed fault procedure opens it so that one engine supplies both.
Sources FCOM DSC-36-10-40 GENERAL / FCOM DSC-36-20 OVERHEAD PANEL / FCOM PRO-ABN-AIR AIR
The X BLEED selector
Open the crossbleed
The cruise again, but ENG 1 BLEED is off and pack 1 has no air. The crossbleed is yours.


-
Predict Where will pack 1's air come from if you turn X BLEED to OPEN?
Try it Turn X BLEED to OPEN.
The two sides are interconnected, and engine 2 now supplies both packs.
Sources FCOM DSC-36-10-40 GENERAL / FCOM DSC-36-20 OVERHEAD PANEL
-
Try it Turn X BLEED back to AUTO.
At AUTO, with the APU bleed valve closed, the crossbleed valve closes and pack 1 is without air again.
Sources FCOM DSC-36-20 OVERHEAD PANEL
What does the crew see, and touch?
On the AIR COND panel: the ENG 1 and ENG 2 BLEED pushbuttons, the APU BLEED pushbutton and the X BLEED selector. An ENG BLEED pushbutton's amber FAULT light comes on, with an ECAM caution, for an overpressure downstream of the bleed valve, a bleed air overheat, a wing or pylon leak on that side, or a bleed valve not closed during engine start or with APU bleed ON; some aircraft add sensor cases. The APU BLEED FAULT light means an APU leak.
On the BLEED page of the SD: the position of each HP valve, bleed valve, the APU bleed valve and the crossbleed valve; each precooler's inlet pressure and outlet temperature; GND on the ground; and ANTI ICE when the WING pushbutton is on. The pressure is green, and amber under 4 PSI or on an overpressure the BMC detects. The temperature is green, and amber on an overheat or, in flight with the wing anti-ice on, below 150 °C.
The green APU BLEED memo shows when the APU is available and APU BLEED is ON. After selecting a control a procedure calls for, the FCTM has the PM check the SD page: its own example is the closure of the crossbleed valve, which should change the page.
Sources FCOM DSC-36-20 OVERHEAD PANEL / FCOM DSC-36-20 ECAM BLEED PAGE / FCOM DSC-36-20 MEMO DISPLAY / FCTM AOP-30-20 HANDLING OVERHEAD PANEL CONTROL
The panel and the BLEED page, together
The same cruise, as the crew sees it: the AIR COND panel and the BLEED page. Press, and read the page.


-
Try it Switch ENG 2 BLEED off and read the BLEED page.
The white OFF light is on and the page shows engine 2's bleed valve closed. On this live aircraft its precooler inlet pressure also drops to zero; the FCOM places the precooler downstream of the bleed valve but gives no figure for a closed one.
Sources FCOM DSC-36-20 OVERHEAD PANEL / FCOM DSC-36-10-20 TEMPERATURE REGULATION AND LIMITATION / FCOM DSC-36-20 ECAM BLEED PAGE
-
Try it Switch ENG 2 BLEED back on.
The valve opens and the pressure returns. Here it reads 42 PSI, inside the A320ceo's regulated 45 ± 5 PSI.
Sources FCOM DSC-36-10-20 PRESSURE REGULATION AND LIMITATION / FCOM DSC-36-20 ECAM BLEED PAGE
What happens when one engine's bleed fails?
The BMC acts first. AIR ENG 1(2) BLEED FAULT triggers with the engine running when the bleed pressure is above 57 PSI (+3/-0), or its temperature above 257 °C for more than 55 s, 270 °C for more than 15 s or 290 °C for more than 5 s; in one version, for some aircraft, the loss of both bleed temperature sensors also triggers it. On an overpressure or overtemperature the BMC closes the bleed valve, and the FAULT light comes on.
The procedure's logic is to have the failed bleed off and to open the crossbleed, so that the other engine supplies both sides. The affected ENG BLEED goes to OFF if its valve has not closed automatically in some versions, and in every case in another, for other aircraft. One precooler then has to serve both sides: in one version, for some aircraft, with both packs on, the pack flow goes to LO with the wing anti-ice off, or the affected pack goes off with it on, and STATUS reads ONE PACK ONLY IF WAI ON. In another the affected pack and the aft cargo hot air go off.
If the bleed valve fails to close, the alert shows the BLEED NOT CLOSED subtitle and the logic turns round: the crossbleed is shut, not opened, the affected pack goes off and so does the wing anti-ice; with engine 1 affected, the APU bleed goes off too.
The reset table allows one reset of the affected bleed after AIR ENG 1(2) BLEED FAULT or BLEED ABNORM PR, a second only if the first fails and the fault came after takeoff with APU bleed ON, and none with BLEED NOT CLOSED.
If a BMC fails, the other still issues the overpressure and wing leak warnings, but the failed side's bleed valve no longer closes automatically. On the A319ceo and A320ceo it also warns of overtemperature, but that side's FAULT light is lost; on the A320neo and A321neo that side's overtemperature protection is lost.
Sources FCOM PRO-ABN-AIR AIR ENG 1(2) BLEED FAULT / FCOM PRO-ABN-AIR AIR / FCOM DSC-36-10-20 PRESSURE REGULATION AND LIMITATION / FCOM DSC-36-20 OVERHEAD PANEL / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES / FCOM PRO-ABN-AIR BLEED NOT CLOSED / FCOM PRO-ABN-ABN-RESET / FCOM DSC-36-10-60 BMC FAILURE
Fail an engine bleed yourself
The cruise, A320ceo, wing anti-ice off. Press the failure, see what the BMC does by itself, then do what the ECAM asks.




Failure Overheat engine 1's bleed
Here the bleed valve closes and the FAULT light comes on at once; on the aircraft the alert waits for the temperatures and times given above. Pack 1 is left without air.
Sources FCOM DSC-36-10-20 PRESSURE REGULATION AND LIMITATION / FCOM DSC-36-20 OVERHEAD PANEL / FCOM PRO-ABN-AIR AIR ENG 1(2) BLEED FAULT
Try it Set PACK FLOW to LO and turn X BLEED to OPEN: on this A320ceo, with the wing anti-ice off and both packs on, that is the procedure's logic.
Engine 2 now supplies both packs. With its one precooler serving both, the FCOM has the pack flow at LO while the wing anti-ice is off. Its line for ENG 1 BLEED applies if the valve has not closed automatically; here the BMC has closed it.
Sources FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES
Why are a leak, and losing both bleeds, so serious?
Leak detection loops run near the hot air ducts in the fuselage, the pylons and the wings, and the APU has a single loop. Each wing has a double loop: a wing leak is declared when both loops detect it, or one does with the other inoperative.
The BMC isolates a leak by itself. A wing leak closes that side's bleed valve, lights its FAULT light and closes the crossbleed valve; on the left, it also closes the APU bleed valve if it is open. A pylon leak does the same, pylon 1 taking the left wing's part, and an APU leak closes the APU bleed valve and the crossbleed valve. The crossbleed and APU closures are inhibited during engine start.
AIR L(R) WING LEAK triggers when both wing loops detect more than 124 °C, AIR ENG 1(2) BLEED LEAK when the pylon loop detects more than 204 °C (with the engine running in one version; both pylon loops in another, for other aircraft). Where a bleed fault opens the crossbleed, their procedures keep it shut: X BLEED to SHUT and, after a left side leak, APU BLEED OFF, each only if the valve has not closed; the affected ENG BLEED OFF if it has not closed automatically in some versions, in every case in another; and the wing anti-ice off. In the versions for some aircraft, AIR BLEED LEAK triggers on a leak with X BLEED at OPEN, and the procedure turns it to SHUT: "Closing the crossbleed valve isolates the bleed leak."
Losing both engine bleeds is the serious combination: AIR ENG 1+2 BLEED FAULT, with a subtitle naming the side (LEFT LEAK, RIGHT LEAK or both) when a wing or pylon leak is involved. Both packs and the wing anti-ice are on the INOP SYS list. The ECAM's logic: keep the wing anti-ice off and try one reset of each bleed whose side is not leaking, with the crossbleed shut if one side leaks. If no bleed returns, or with leaks on both sides, both bleeds go off and the aircraft descends to FL 100 or MEA-MORA, and the crew applies the separate BLEED 1+2 procedure.
With no leak, or a right side leak, it starts the APU (a fire or a start air valve failed open counts as a leak on its engine's side) and uses its bleed at or below FL 200 to recover pressurisation, never for wing anti-ice; with a left side leak it does not use the APU. Where the APU cannot help, the engine bleeds are tried again at or below FL 100 or MEA-MORA. With leaks on both sides no engine bleed can be recovered: the aircraft stays at or below FL 100 or MEA-MORA, and RAM AIR goes on once the cabin differential pressure is below 1 psi.
After a wing or pylon leak, BLEED NOT CLOSED or both bleeds lost, STATUS carries the icing consequences: avoid icing conditions and, with severe ice accretion, a minimum speed of VLS +10 / G DOT, MANEUVER WITH CARE and the landing distance procedure.
Sources FCOM DSC-36-10-50 LEAK DETECTION / FCOM PRO-ABN-AIR AIR L(R) WING LEAK / FCOM PRO-ABN-AIR AIR ENG 1(2) BLEED LEAK / FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES / FCOM PRO-ABN-AIR AIR BLEED LEAK / FCOM PRO-ABN-AIR AIR ENG 1+2 BLEED FAULT / FCOM PRO-ABN-AIR LEFT LEAK / FCOM PRO-ABN-AIR RIGHT LEAK / FCOM PRO-ABN-AIR LEFT LEAK AND RIGHT LEAK / FCOM PRO-ABN-AIR
What a left wing leak closes
A leak, then both bleeds
The same cruise, APU off. Press a failure and compare.



Failure Leak hot air in the left wing
Here the leak signal closes engine 1's bleed valve and lights its FAULT light at once. The crossbleed valve, at AUTO with no APU bleed, was already closed and stays closed. Pack 1 is left without air, and STATUS will list it inoperative. The ECAM's ENG 1 BLEED and X BLEED lines apply only if those valves have not closed, so here the leak signal has done their work: the wing anti-ice stays off and the crew avoids icing conditions.
Sources FCOM DSC-36-10-50 LEAK DETECTION / FCOM DSC-36-20 OVERHEAD PANEL / FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES
Failure Lose both engine bleeds
Here both bleed valves close on an overheat, and with the APU off neither pack has air: a reset of each bleed comes first.
Sources FCOM PRO-ABN-AIR AIR ENG 1+2 BLEED FAULT / FCOM PRO-ABN-AIR AIR
What differs between the A319, A320 and A321, ceo and neo?
The layout is the same on the A319ceo, A320ceo, A320neo and A321neo: two engine bleed systems, the APU, an HP ground connection, a crossbleed valve, two BMCs and leak detection loops. What changes are figures and protections.
- HP stage pressure: 36 ± 4 PSI on the A319ceo and A320ceo, 65 ± 15 PSI on the A320neo and A321neo.
- Bleed valve opening: upstream pressure above 8 PSI on the A319ceo and A320ceo, above 15 PSI on the A320neo and A321neo. The neo types and some A320ceo also need at least one bleed consumer (a pack or the wing anti-ice) on, on the same side, or on the other side with the crossbleed valve open.
- Overpressure valve: closes above 75 PSI on the A319ceo and some A320ceo, above 80 PSI on other A320ceo, above 75 PSI on the A320neo and A321neo.
- Precooler: about 200 °C on every type; on the A320neo and A321neo about 160 °C in the climb or hold with both engine bleeds and no wing anti-ice.
- Pylon leak loops: a single loop on the A319ceo and A320ceo, a double loop on the A320neo and A321neo.
- FAULT light: the A320neo and A321neo add an HP valve failed open on the ground, bleed temperature sensor (BTS) failures and, on LEAP-1A engines only, a fan duct burst detected by the FADEC; some A320ceo add a dual BTS failure.
Sources FCOM DSC-36-10-10 GENERAL / FCOM DSC-36-10-20 ARCHITECTURE / FCOM DSC-36-10-20 AIR BLEED SELECTION / FCOM DSC-36-10-20 PRESSURE REGULATION AND LIMITATION / FCOM DSC-36-10-20 TEMPERATURE REGULATION AND LIMITATION / FCOM DSC-36-10-50 LEAK DETECTION / FCOM DSC-36-20 OVERHEAD PANEL
Go further
The studio's own lessons on this system, played step by step on the panel and the SD page, and the Interactive Flight Deck at the AIR COND panel.
In the ECAM Trainer
Work these pneumatics and bleed air failures as a crew, line by line against the FCOM, in the ECAM Trainer. Red: a warning; amber: a caution.
Limitations
- APU bleed: max altitude to assist engine startFCOM LIM-APU · AUXILIARY POWER UNIT20 000 ft
- APU bleed: max altitude for air conditioning and pressurisation, single packFCOM LIM-APU · AUXILIARY POWER UNIT22 500 ft
- APU bleed: max altitude for air conditioning and pressurisation, dual packAPU bleed for wing anti-ice is not permittedFCOM LIM-APU · AUXILIARY POWER UNIT15 000 ft
Key abbreviations
- BMC
- Bleed Monitoring Computer
- HP
- High Pressure
- IP
- Intermediate Pressure
- APU
- Auxiliary Power Unit
- ECAM
- Electronic Centralised Aircraft Monitoring
- SD
- System Display
- FTIS
- Fuel Tank Inerting System
- FADEC
- Full Authority Digital Engine Control System
- BTS
- Bleed Temperature Sensor
- WAI
- Wing Anti-Ice
- VLS
- Lowest Selectable Speed
- MEA
- Minimum En Route Altitude
- MORA
- Minimum Off Route Altitude
- FL
- Flight Level
- PM
- Pilot Monitoring
- FCTM
- Flight Crew Techniques Manual

A320 pneumatics and bleed air in the Knowledge Trainer
119 questions on this system, each explained from the FCOM with its source, and the trainer brings back what you got wrong until it sticks.
Train this systemWritten in our own words from the FCOM and the FCTM; each part names the units it rests on. The live aircraft is the platform's systems model, the same one the ECAM Trainer and the flight deck run. Aircraft differ by type, engine and options: your aircraft's FCOM and your operator's procedures always come first. How we write and check these pages.
Learn it from the FCOM, one question at a time.
The Knowledge Trainer has 2,517 questions across all 18 systems, each explained from the FCOM. Start free today, or open everything with A320 Knowledge+.
For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.
Related
- A320 air conditioning and pressurisationTwo packs cool the air, trim air warms each zone, and one outflow valve holds the cabin altitude, built up one piece at a time, with the…
- A320 ice and rain protectionHot air for three slats on each wing, each engine's own air for its intake, electrical heat for the windows and probes, and wipers for the…
- A320 engines and APUTwo FADEC-run turbofans and a self-contained APU, built up one idea at a time, with the live pedestal, APU panel, E/WD and SD pages to try…
- A320 fire protectionTwo loops that must agree while both work, a pushbutton that isolates an engine, bottles the crew fires, and one APU bottle that fires…
- All 18 A320 systemsWhat each system is, and where to study it