Free to read · live

A320 air conditioning and pressurisation

Two packs cool the air, trim air warms each zone, and one outflow valve holds the cabin altitude, built up one piece at a time, with the live panels and SD pages to try every idea on.

Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy

The answer first

In short

The A320 cools hot air from the pneumatic system in two packs, mixes it with recirculated cabin air and sends it to three zones: the cockpit, the forward and the aft cabin. One outflow valve, driven by a controller, lets it out and so sets the cabin pressure.

  • Packs: two, automatic and independent; one alone runs at high flow.
  • Temperature: the lowest zone demand sets the packs' outlet temperature; trim air valves add hot air for each zone's own selection.
  • Pressure: two controllers, one active at a time; in cruise the cabin altitude target is limited to about 8 000 ft.
  • Protection: two safety valves, at 8.6 PSI above and 1 PSI below ambient.
  • The serious failures: AIR PACK 1+2 FAULT, with no pack to recover, and, above FL 100, CAB PR EXCESS CAB ALT bring a descent.

Sources FCOM DSC-21-10-10 GENERAL / FCOM DSC-21-10-20 MIXER UNIT / FCOM DSC-21-20-10 GENERAL / FCOM DSC-21-20-20 OUTFLOW VALVE / FCOM DSC-21-10-20 AIR CONDITIONING PACK / FCOM DSC-21-10-30 TEMPERATURE REGULATION / FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL / FCOM DSC-21-20-20 CABIN PRESSURE CONTROLLERS / FCOM DSC-21-20-30 AUTOMATIC PRESSURE CONTROL MODE / FCOM DSC-21-20-20 SAFETY VALVES / FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-CAB_PR CAB PR

The COND page of the A320ceo ECAM, as the platform draws it: a healthy aircraft in the cruise
The COND pageAs our ECAM Trainer draws it: an A320ceo, healthy, in the cruise.

Why does the A320 need air conditioning and pressurisation?

Start with the people on board. They need fresh air, a comfortable temperature, and a cabin altitude far below the aircraft's. The air conditioning gives continuous air renewal and holds a selected temperature in three zones, the cockpit, the forward cabin and the aft cabin, each controlled independently.

The pressurisation adjusts the cabin altitude and its rate of change for a comfortable flight; in cruise the cabin altitude target is limited to about 8 000 ft. Beside them, a ventilation system cools the avionics and the flight deck panels.

Sources FCOM DSC-21-10-10 GENERAL / FCOM DSC-21-20-10 GENERAL / FCOM DSC-21-20-30 AUTOMATIC PRESSURE CONTROL MODE / FCOM DSC-21-30-10 GENERAL / FCOM DSC-21-30-20 GENERAL

What the system does

What the system doesOne box, air conditioning, pressurisation and ventilation, above its four jobs: continuous fresh air, the temperature of three zones, the cabin altitude, and avionics cooling. Air conditioning, pressurisation, ventilationFresh aircontinuous renewalTemperaturethree zonesCabin altitudeabout 8,000 ft in cruiseAvionicskept cool
One chapter, four jobs: fresh air, a temperature in each of three zones, a cabin altitude limited to about 8,000 ft in cruise, and cool avionics.

What is the simplest way to picture it?

Picture air moving through the aircraft one way. It arrives hot from the pneumatic system, passes a pack flow control valve into each of two packs, and comes out cold. The mixer unit blends it with cabin air, and the mix goes to the cockpit and the cabin.

Then the air has to leave, and how fast it leaves is the whole of pressurisation. One outflow valve, aft on the right side of the fuselage, lets it out: open it and the cabin altitude climbs, close it and it comes down. Two safety valves stand by if the cabin pressure goes too high or too low.

Sources FCOM DSC-21-10-10 GENERAL / FCOM DSC-21-10-20 AIR CONDITIONING PACK / FCOM DSC-21-10-20 MIXER UNIT / FCOM DSC-21-20-20 OUTFLOW VALVE / FCOM DSC-21-20-20 SAFETY VALVES / FCOM DSC-21-20-30 MANUAL PRESSURE CONTROL MODE / FCOM DSC-21-20-40 OVERHEAD PANEL

Step 1: air in, through the packs, out through one valve

Step 1: air in, through the packs, out through one valveBleed air at the top feeds PACK 1 and PACK 2; both feed the mixer unit, which feeds the cockpit and cabin; air leaves through the outflow valve, with the safety valves beside it. Bleed airfrom the pneumatic systemPACK 1cools the airPACK 2cools the airMixer unitCockpit and cabinthree zonesOutflow valveair outSafety valvestoo high, too low
Step 1 of 3. Bleed air through two packs into the mixer unit, then to the cockpit and the cabin, and out through the outflow valve. Dashed: the safety valves, which open only if the pressure goes too high or too low.

How does a pack make cold air out of hot bleed air?

Follow the air through one pack. The primary heat exchanger cools it, the air cycle machine's compressor squeezes it to a higher pressure and temperature, the main heat exchanger cools it again, and it expands through the turbine, which drives the compressor and the cooling fan. That leaves it very cold; a water separator dries it before the turbine.

The pack's controller sets the outlet temperature with the bypass valve and the ram air inlet flap, which closes during takeoff and landing to keep foreign matter out, and the flow with the flow control valve. That valve also closes by itself for an engine start or the FIRE or DITCHING pushbutton. For an overheat the FCOM reads two ways: the valve's description gives its automatic closure on the ground only, while the PACK pushbutton lists a compressor outlet overheat, with no phase, among the cases in which it does not open.

The crew sets the flow with PACK FLOW: LO (80 %), NORM (100 %) or HI (120 %). The system overrides the choice when it must: in single pack operation or on APU bleed it selects HI, and from LO it goes up to normal flow when the cooling demand cannot be met.

Sources FCOM DSC-21-10-20 AIR CONDITIONING PACK / FCOM DSC-21-10-20 PACK FLOW CONTROL VALVE / FCOM DSC-21-10-30 AIR CONDITIONING SYSTEM CONTROLLERS / FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL

Inside a pack

Inside a packThe pack valve feeds the primary heat exchanger, then the compressor, then the main heat exchanger, then the water separator and the turbine, which drives the compressor; cold air goes out to the mixer unit. drivesPack valveflow controlHeat exchangerprimaryCompressorair cycle machineHeat exchangermainWater separatorTurbinevery cold airCold airto the mixer unit
Hot air in through the flow control valve, cooled, compressed, cooled again, dried and expanded through the turbine, which drives the compressor: cold air out to the mixer unit.
Live aircraft

Switch the packs yourself

In flight, both packs at NORM flow, the cabin about 8 PSI above the outside air. The AIR COND panel works; the BLEED page shows each pack's flow.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
  1. Predict If you switch PACK 1 off, what does pack 2 do?

    Try it Switch PACK 1 off.

    In single pack operation the PACK FLOW selection no longer counts: HI is selected automatically. Pack 1's flow control valve is closed.

    Sources FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL

  2. Try it Switch PACK 1 back on, and PACK FLOW to LO.

    Both packs at LO, 80 %: the crew picks the flow for the passengers and the conditions.

    Sources FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL

  3. Predict With the cabin about 8 PSI above the outside air, will outside air come in if you open the emergency ram air inlet?

    Try it Switch RAM AIR on.

    The inlet opens, but at 1 PSI or more a check valve downstream of the ram air door stays shut, so nothing flows. The procedures that use ram air call for it once the differential pressure is below 1 PSI and the aircraft below FL 100.

    Sources FCOM DSC-21-10-20 EMERGENCY RAM AIR / FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL / FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-COND COND

How do three zones get three temperatures?

The packs make one temperature between them. The controller compares each zone's selected and actual temperatures, and the lowest demand sets the outlet temperature of both packs.

The mixer unit adds cabin air, drawn back by the recirculation fans. Then trim air warms each zone to its own selection: hot air, tapped upstream of the packs, passes the hot air pressure regulating valve to three trim air valves, one for each zone, each adjusting its zone's temperature by adding hot air.

Depending on the aircraft, a zone controller and two pack controllers do this, or two air conditioning system controllers (ACSC): ACSC 1 runs the cockpit and the hot air valve, ACSC 2 the two cabin zones. Each controller has two lanes, and one lane failing has no effect.

The crew sets the COCKPIT, FWD CABIN and AFT CABIN selectors, 18 °C to 30 °C; in cruise the cabin crew can trim each cabin zone by ± 2.5 °C from a panel, where fitted. The COND page shows each zone's temperature, its duct temperature (amber at 80 °C), its trim air valve and the hot air valve.

Sources FCOM DSC-21-10-30 TEMPERATURE REGULATION / FCOM DSC-21-10-20 MIXER UNIT / FCOM DSC-21-10-20 HOT-AIR PRESSURE-REGULATING VALVE / FCOM DSC-21-10-20 TRIM AIR VALVES / FCOM DSC-21-10-10 GENERAL / FCOM DSC-21-10-40 GENERAL / FCOM DSC-21-10-40 / FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL / FCOM DSC-21-10-50 ECAM COND PAGE

Step 2: one cold mix, three warm zones

Step 2: one cold mix, three warm zonesThe step 1 picture, with the hot air valve taking bleed air to the trim air valves, which feed the zones, and the cabin fans bringing recirculated air to the mixer unit. Bleed airfrom the pneumatic systemHot air valvetapped upstreamPACK 1cools the airPACK 2cools the airMixer unitCabin fansrecirculated airTrim air valvesone per zoneCockpit and cabinthree zonesOutflow valveair outSafety valvestoo high, too low
Step 2 of 3. The cabin fans bring cabin air back to the mixer unit. Hot air, tapped upstream of the packs, passes the hot air valve to a trim air valve for each zone.
Live aircraft

Hot air and the three zones

In flight, both packs running and HOT AIR on. The COND page shows each zone, its duct temperature and its trim air valve.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The E/WD as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
  1. Predict If you switch HOT AIR off, what happens to the trim air valves?

    Try it Switch HOT AIR off.

    The hot air valve closes and the trim air valves close with it. The COND page shows the hot air valve crossline in amber: closed, with its pushbutton off.

    Sources FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL / FCOM DSC-21-10-50 ECAM COND PAGE

  2. Try it Switch HOT AIR back on.

    The valve regulates hot air pressure again, and the trim air valves go back to adjusting each zone.

    Sources FCOM DSC-21-10-20 TRIM AIR VALVES / FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL

Failure Overheat the cockpit duct

The HOT AIR FAULT light comes on, and the hot air valve and the trim air valves close by themselves. The caution comes when a duct passes 88 °C, or 80 °C four times in one flight. Nothing to press yet: once the duct is below 70 °C, the ECAM has the crew select HOT AIR off then on to reopen the valve.

Sources FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL / FCOM PRO-ABN-COND COND FWD CAB/AFT CAB/CKPT DUCT OVHT / FCOM PRO-ABN-COND COND

Work this failure in the ECAM Trainer

What keeps the avionics cool?

The avionics have their own ventilation, fully automatic, run by the avionics equipment ventilation controller (AEVC). Two electric fans, the blower and the extract fan, circulate air around the avionics whenever the aircraft is electrically supplied.

Where that air comes from depends on the skin temperature. On the ground before takeoff power, with the skin above the ground threshold (12 °C rising), the circuit is open: skin air inlet and outlet valves open to the outside; below it, closed. After takeoff power it is closed, or intermediate, partially open, with the skin above 35 °C (rising).

The crew meets it when something fails: a FAULT light in BLOWER or EXTRACT, with an ECAM alert. OVRD puts the system in closed circuit and adds air from the air conditioning; with both at OVRD, that air goes overboard.

A separate fan draws cabin air through the lavatories and galleys, past the cabin temperature sensors, and out near the outflow valve.

Sources FCOM DSC-21-30-20 GENERAL / FCOM DSC-21-30-20 MAIN COMPONENTS / FCOM DSC-21-30-20 NORMAL OPERATION, OPEN-CIRCUIT CONFIGURATION / FCOM DSC-21-30-20 NORMAL OPERATION, CLOSE-CIRCUIT CONFIGURATION / FCOM DSC-21-30-20 NORMAL OPERATION, INTERMEDIATE CONFIGURATION / FCOM DSC-21-30-60 OVERHEAD PANEL / FCOM DSC-21-30-20 ABNORMAL OPERATION / FCOM DSC-21-30-20 / FCOM DSC-21-10-30 TEMPERATURE REGULATION / FCOM DSC-21-30-50 LAVATORY AND GALLEY

Avionics ventilation: three configurations

Avionics ventilation: three configurationsThe AEVC above three configurations: open circuit on the ground before takeoff power with the skin above 12 °C, closed circuit on a cold ground or after takeoff power, intermediate after takeoff power with the skin above 35 °C. AEVCBLOWER and EXTRACT at AUTOOpen circuitground, skin above 12 °CClosed circuitcold ground, or TO powerIntermediateskin above 35 °C
With BLOWER and EXTRACT at AUTO, the AEVC chooses: open circuit on a warm ground before takeoff power, closed on a cold ground or after takeoff power, or intermediate with the skin above 35 °C.

Who holds the cabin pressure?

Two identical, independent cabin pressure controllers (CPC), one active and one on standby. The active one drives the outflow valve through its own automatic motor; the actuator also holds the other automatic motor and a manual one, and any one of the three can move the valve.

Control changes hands automatically 70 s after each landing, and if the operating system fails. A controller normally uses the landing elevation and QNH from the FMGC and the pressure altitude from the ADIRS; without FMGC data, the captain's baro reference and the LDG ELEV selection.

For manual mode each controller has a backup section with its own pressure sensor; where fitted, a residual pressure control unit (RPCU) opens the outflow valve on the ground if abnormal pressure remains with both controllers failed or MAN selected, the engines shut down or the airspeed below 100 kt.

On the CABIN PRESS panel: MODE SEL (AUTO, or MAN for the manual motor), the MAN V/S CTL switch, the LDG ELEV knob (AUTO, or -2 000 to 14 000 ft) and the guarded DITCHING pushbutton.

Sources FCOM DSC-21-20-10 GENERAL / FCOM DSC-21-20-20 CABIN PRESSURE CONTROLLERS / FCOM DSC-21-20-20 OUTFLOW VALVE / FCOM DSC-21-20-30 AUTOMATIC PRESSURE CONTROL MODE / FCOM DSC-21-20-20 / FCOM DSC-21-20-40 OVERHEAD PANEL

Two controllers, three motors, one outflow valve

Two controllers, three motors, one outflow valveCPC 1, active, drives automatic motor 1; CPC 2, on standby, has automatic motor 2; MAN V/S CTL drives the manual motor; all three motors are in the outflow valve's actuator. CPC 1activeMAN V/S CTLin MAN onlyCPC 2standbyAuto motorsystem 1MAN motormanualAuto motorsystem 2Outflow valveany one motor can move it
One controller drives the outflow valve through its automatic motor while the other waits; in MAN, the crew's MAN V/S CTL switch drives the manual motor.
Live aircraft

The CABIN PRESS panel and page

In cruise, system 1 in control, the outflow valve nearly closed. The CABIN PRESS panel works; watch the CAB PRESS page.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
  1. Predict If you turn LDG ELEV from AUTO to 2, which landing elevation does the controller use?

    Try it Turn LDG ELEV to 2.

    Out of AUTO, the schedule uses the knob's elevation instead of the FMGS's; the page shows LDG ELEV MAN, and on the aircraft the green MAN LDG ELEV memo appears. The knob's scale is only an indication: the ECAM figure is the accurate one.

    Sources FCOM DSC-21-20-40 OVERHEAD PANEL / FCOM DSC-21-20-40 ECAM CAB PRESS PAGE / FCOM DSC-21-20-40 MEMO DISPLAY

  2. Try it Set LDG ELEV back to AUTO, then MODE SEL to MAN.

    MAN shows on the pushbutton and the page: the automatic motors lose power and MAN V/S CTL drives the manual motor, UP to open the valve, DN to close it. Here the cabin figures are fixed, so MAN V/S CTL does not move them.

    Sources FCOM DSC-21-20-30 MANUAL PRESSURE CONTROL MODE / FCOM DSC-21-20-40 OVERHEAD PANEL / FCOM DSC-21-20-40 ECAM CAB PRESS PAGE

  3. Predict With MODE SEL still at MAN, will DITCHING close the outflow valve?

    Try it Press DITCHING.

    DITCHING sends a close signal to the outflow valve, the emergency ram air inlet, the avionics ventilation inlet and extract valves and the pack flow control valves, but the outflow valve does not close automatically under manual control.

    Sources FCOM DSC-21-20-40 OVERHEAD PANEL

  4. Try it Set MODE SEL back to AUTO.

    Back in automatic, the operating system closes the outflow valve too. Here system 1 takes control again; on the aircraft, MAN for at least 10 s and back to AUTO selects the other system.

    Sources FCOM DSC-21-20-40 OVERHEAD PANEL

What does the cabin do from gate to gate?

On the ground before takeoff the outflow valve is fully open, so there is no residual pressure. For takeoff the controller pre-pressurises the cabin at 400 ft/min until the differential pressure reaches 0.1 PSI, to avoid a surge at rotation. At liftoff the climb begins, the cabin altitude following a fixed law that takes the aircraft's rate of climb into account; if the aircraft does not climb, the abort mode takes the cabin back to the takeoff altitude plus 0.1 PSI.

In cruise it holds the level-off value or the landing field elevation, whichever is higher, the target limited to about 8 000 ft. In descent it sets a rate, at most 750 ft/min, to reach the landing field pressure plus 0.1 PSI shortly before landing. At touchdown the rest is released at 500 ft/min, and 55 s after landing the valve is fully open.

The crew watches it on the CAB PRESS page: the differential pressure turns amber at or below -0.4 PSI or at or above 8.5 PSI, the cabin vertical speed pulses above 1 750 ft/min, and the cabin altitude pulses at or above 8 800 ft and turns red above 9 550 ft.

Sources FCOM DSC-21-20-10 GENERAL / FCOM DSC-21-20-30 AUTOMATIC PRESSURE CONTROL MODE / FCOM DSC-21-20-40 ECAM CAB PRESS PAGE / FCOM DSC-21-30-60 ECAM CAB PRESS PAGE

The automatic schedule

The automatic scheduleSix phases in a row: ground, outflow valve open; takeoff, to 0.1 PSI at 400 ft/min; climb, a fixed law; cruise, about 8,000 ft at most; descent, 750 ft/min at most; landing, 500 ft/min then fully open. Groundoutflow valve openTakeoff0.1 PSI, 400 ft/minClimba fixed lawCruiseabout 8,000 ftDescent750 ft/min at mostLanding500 ft/min, then open
From gate to gate in automatic: open on the ground, a little pressure for takeoff, a fixed law in climb, about 8,000 ft at most in cruise, at most 750 ft/min in descent, and the rest released at touchdown.

What happens when a pack, a duct or a controller fails?

A single pack first. AIR PACK 1(2) FAULT comes when the pack flow control valve disagrees with its commanded position or is closed; AIR PACK 1(2) OVHT when the compressor outlet passes 260 °C. Either way the ECAM has the crew switch the pack off; after an overheat it can go back on once the overheat is out. A pack whose air cycle machine seizes may still run, at reduced flow.

AIR PACK 1+2 FAULT triggers when both ACSCs have failed, and both packs are lost. The logic, but for an extra branch one version adds (below): both packs off, a descent to FL 100 or MEA-MORA, whichever is higher, and ram air once the differential pressure is below 1 PSI and the aircraft below FL 100. Then the outflow valve opens to about 50 % under automatic control, and ram air flows into the mixer unit.

Too much hot air is the other failure: the duct overheat above. If it does not recover, temperature regulation is by the packs only, still automatic. With COND HOT AIR FAULT (the hot air valve against its command), HOT AIR goes off; if the valve stays open and the duct overheat persists, the procedure switches both packs off, with the same descent and ram air.

Sources FCOM PRO-ABN-AIR AIR PACK 1(2) FAULT / FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-AIR AIR PACK 1(2) OVHT / FCOM DSC-21-10-40 AIR CYCLE MACHINE FAILURE / FCOM PRO-ABN-AIR AIR PACK 1+2 FAULT / FCOM DSC-21-10-40 / FCOM DSC-21-10-20 EMERGENCY RAM AIR / FCOM PRO-ABN-COND / FCOM PRO-ABN-COND COND HOT AIR FAULT / FCOM PRO-ABN-COND COND

Step 3: both controllers lost (AIR PACK 1+2 FAULT)

Step 3: both controllers lost (AIR PACK 1+2 FAULT)The step 2 picture with both packs lost and the packs and hot air links dashed; the emergency ram air inlet now feeds the mixer unit. Bleed airfrom the pneumatic systemHot air valvetapped upstreamPACK 1lostPACK 2lostRam airbelow 1 PSIMixer unitCabin fansrecirculated airTrim air valvesone per zoneCockpit and cabinthree zonesOutflow valve50 % with ram airSafety valvestoo high, too low
Step 3 of 3. With both controllers failed, both packs are lost and the hot air valve and trim air valves close; once the differential pressure is below 1 PSI, the emergency ram air inlet can feed the mixer unit. Dashed: what no longer flows.
Live aircraft

Fail the packs yourself

The same aircraft in flight. Press a failure, see what the aircraft does by itself, then do what the ECAM asks.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The E/WD as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model

Failure Overheat pack 1

Here pack 1's flow control valve closes as the overheat comes, and pack 2 goes to high flow. On the aircraft the caution triggers above 260 °C at the compressor outlet, with the PACK 1 FAULT light; the valve's description gives its automatic closure for an overheat on the ground only, the PACK pushbutton lists a compressor outlet overheat among the cases in which it does not open, and the ECAM has the crew switch the pack off.

Sources FCOM PRO-ABN-AIR AIR PACK 1(2) OVHT / FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL / FCOM DSC-21-10-20 PACK FLOW CONTROL VALVE / FCOM PRO-ABN-AIR AIR

Work this failure in the ECAM Trainer

Try it Switch PACK 1 off, as the ECAM asks.

High flow is selected automatically on the remaining pack. The FAULT light goes off when the overheat disappears, and the pack can then go back on.

Sources FCOM PRO-ABN-AIR AIR

Failure Fail both air conditioning controllers

With both lanes of a controller failed its pack is lost, and here both are. The BLEED page's users indication turns amber, as it does in flight with both pack valves closed and the ram air not fully open.

Sources FCOM PRO-ABN-AIR AIR PACK 1+2 FAULT / FCOM DSC-21-10-40 / FCOM DSC-21-10-50 ECAM BLEED PAGE

Work this failure in the ECAM Trainer

Try it Switch both packs off, as the ECAM asks.

Next, the descent to FL 100 or MEA-MORA, whichever is higher, and RAM AIR once the differential pressure is below 1 PSI and the aircraft below FL 100.

Sources FCOM PRO-ABN-AIR AIR

Why is a pressurisation failure so serious?

One controller failing is absorbed: CAB PR SYS 1(2) FAULT, and the other system takes over by itself.

Both failing is not. With CAB PR SYS 1+2 FAULT the crew selects MAN and flies the cabin with MAN V/S CTL. The valve is slow: a change may take 10 s to notice, and the procedure may not avoid a depressurisation. The STATUS gives target rates, climb 500 ft/min and descent 300 ft/min. In manual mode the valve does not open by itself at touchdown: the differential pressure must be zero before the doors are opened.

CAB PR SAFETY VALVE OPEN (a safety valve not fully closed on the ground, or for more than 1 min in flight) is read with the differential pressure: above 8 PSI, manual control to bring it down, and a lower flight level if that fails; below 0 PSI, expect a high cabin rate and reduce the aircraft's vertical speed.

The most serious is CAB PR EXCESS CAB ALT: in cruise, the cabin above 9 550 ft; in climb or descent, above 9 550 ft or 1 000 ft above the airfield pressure altitude, whichever is higher. The crew relies on it even if the CAB PRESS page does not confirm it: it can come from a different sensor. Above FL 100 the logic is crew oxygen masks and a descent, flown as the EMER DESCENT above FL 160, the maximum flight level then FL 100 or MEA-MORA; with the cabin above 14 000 ft, PAX OXY MASKS MAN ON confirms the passenger masks are released.

The FCTM highly recommends the autopilot and autothrust to initiate the descent: at idle, high speed and speed brakes extended, it comes down at about 7 000 ft/min.

Sources FCOM DSC-21-20-30 AUTOMATIC PRESSURE CONTROL MODE / FCOM PRO-ABN-CAB_PR CAB PR SYS 1(2) FAULT / FCOM PRO-ABN-CAB_PR CAB PR / FCOM DSC-21-20-30 MANUAL PRESSURE CONTROL MODE / FCOM PRO-ABN-CAB_PR CAB PR SYS 1+2 FAULT / FCOM PRO-ABN-CAB_PR CAB PR SAFETY VALVE OPEN / FCOM PRO-ABN-CAB_PR CAB PR EXCESS CAB ALT / FCTM PR-AEP-MISC EMER DESCENT

Live aircraft

Fail the pressurisation yourself

In cruise, system 1 in control. Press a failure and watch the CAB PRESS page.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The E/WD as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model

Failure Fail system 1

System 2 takes over by itself and the page shows SYS 1 in amber. On the aircraft, CAB PR SYS 1 FAULT puts CAB PR 1 on the STATUS page's inoperative systems.

Sources FCOM DSC-21-20-30 AUTOMATIC PRESSURE CONTROL MODE / FCOM DSC-21-20-40 ECAM CAB PRESS PAGE / FCOM PRO-ABN-CAB_PR CAB PR SYS 1(2) FAULT / FCOM PRO-ABN-CAB_PR CAB PR

Failure Fail both controllers

No automatic system is left: the MODE SEL FAULT light comes on, as it does only when both automatic systems are faulty.

Sources FCOM DSC-21-20-40 OVERHEAD PANEL / FCOM PRO-ABN-CAB_PR CAB PR SYS 1+2 FAULT

Work this failure in the ECAM Trainer

Try it Set MODE SEL to MAN, as the ECAM asks.

MAN shows and FAULT is out. From here the crew flies the cabin with MAN V/S CTL, short inputs to target a precise rate, watching the cabin V/S.

Sources FCOM DSC-21-20-40 OVERHEAD PANEL / FCOM PRO-ABN-CAB_PR CAB PR

Failure Open a safety valve

SAFETY and its diagram turn amber when either valve is not closed. Here the caution comes at once; in flight on the aircraft it needs the valve not fully closed for more than 1 min.

Sources FCOM DSC-21-20-40 ECAM CAB PRESS PAGE / FCOM PRO-ABN-CAB_PR CAB PR SAFETY VALVE OPEN

Work this failure in the ECAM Trainer

What differs between the A319, A320 and A321, ceo and neo?

The FCOM describes the same packs, mixer unit, trim air, pressure controllers, outflow valve and safety valves for every type. Among the differences it marks:

  • Pack valves after an engine start on the ground: reopening is delayed 30 s on the A319ceo and A320ceo, 60 s on the A320neo and A321neo.
  • NORM flow on the ground with both engines running: limited on the A320neo and A321neo, to 85 % or 90 % depending on the aircraft.
  • PACKS on the E/WD with the thrust levers in TOGA or FLX/MCT: A320neo and A321neo.
  • AIR PACK 1(2) REGUL FAULT: in one version, for some aircraft, it can also trigger when the EIU's engine air flow and the ACSC's pack flow disagree; on the ground that version then has the crew switch the pack off.
  • AIR PACK 1+2 FAULT: one version, for some aircraft, has an extra branch for a pack switched off earlier after a failure of its engine bleed.
  • Foot heaters: some A320ceo have an electrical heater in each cockpit foot air outlet, with CAPT and F/O HEATER switches raising the outlet air by 12.5 °C or 25 °C.

Sources FCOM DSC-21-10-10 GENERAL / FCOM DSC-21-10-20 AIR CONDITIONING PACK / FCOM DSC-21-20-10 GENERAL / FCOM DSC-21-20-20 SAFETY VALVES / FCOM DSC-21-20-20 CABIN PRESSURE CONTROLLERS / FCOM DSC-21-10-30 AIR CONDITIONING SYSTEM CONTROLLERS / FCOM DSC-21-10-50 CONTROLS ON OVERHEAD PANEL / FCOM DSC-21-10-50 ENGINE WARNING DISPLAY / FCOM PRO-ABN-AIR AIR PACK 1(2) REGUL FAULT / FCOM PRO-ABN-AIR AIR / FCOM PRO-ABN-AIR ABNORMAL AND EMERGENCY PROCEDURES / FCOM DSC-21-10-10 ARCHITECTURE / FCOM DSC-21-10-30 COCKPIT - ELECTRICAL HEATERS

Go further

The studio's own lessons on this system, played step by step on the panel and the SD page, and the Interactive Flight Deck at the AIR COND panel.

Open the flight deck at this panel

In the ECAM Trainer

Work these air conditioning and pressurisation failures as a crew, line by line against the FCOM, in the ECAM Trainer. Red: a warning; amber: a caution.

Open the ECAM Trainer

Memory items

The memory items that belong to this system. Each one is on our memory items page in full, with its conditions and references.

  1. EMER DESCENTCallout EMERGENCY DESCENTCabin altitude is excessive (CAB PR EXCESS CAB ALT warning) and an emergency descent is needed. Rely on the warning even if the CAB PRESS SD page does not confirm it.

Limitations

  • Max positive differential pressureTolerance ± 7 hPa (0.1 PSI)FCOM LIM-AIR · CABIN PRESSURE
    9.0 PSI
  • Max negative differential pressureFCOM LIM-AIR · CABIN PRESSURE
    -1.0 PSI
  • Safety relief valve settingFCOM LIM-AIR · CABIN PRESSURE
    8.6 PSI
  • Tolerance on max Δp and safety valve settingFCOM LIM-AIR · CABIN PRESSURE
    ± 7 hPa (0.1 PSI)
  • With passengers on board, it is not recommended to exceed this time without air conditioning supplyFCOM LIM-AIR · GENERAL
    20 min
  • Ground operation on aircraft electrical power, normal avionics ventilation: no time limitation up to OATFCOM LIM-AIR · AVIONICS VENTILATION
    49 °C
  • Ground electrical power time limit, avionics ventilation normal, 49 °C < OAT ≤ 55 °CFCOM LIM-AIR · AVIONICS VENTILATION
    2 h
  • Ground electrical power time limit, avionics ventilation normal, 55 °C < OAT ≤ 60 °CFCOM LIM-AIR · AVIONICS VENTILATION
    1 h
  • Ground electrical power time limit, avionics ventilation normal, 60 °C < OAT ≤ 64 °CFCOM LIM-AIR · AVIONICS VENTILATION
    0.5 h

Every limitation, by system

Videos

Every video on this system

Key abbreviations

ACSC
Air Conditioning System Controller
CPC
Cabin Pressure Controller
RPCU
Residual Pressure Control Unit
AEVC
Avionic Equipment Ventilation Controller
ECAM
Electronic Centralised Aircraft Monitoring
SD
System Display
E/WD
Engine/Warning Display
FMGS
Flight Management and Guidance System
FMGC
Flight Management and Guidance Computer
ADIRS
Air Data Inertial Reference System
EIU
Engine Interface Unit
LGCIU
Landing Gear Control Interface Unit
QNH
Sea Level Atmosphere Pressure
APU
Auxiliary Power Unit
MEA
Minimum En Route Altitude
MORA
Minimum Off Route Altitude
FL
Flight Level
V/S
Vertical Speed
TOGA
Takeoff - Go-Around
FCTM
Flight Crew Techniques Manual

The FCOM's full list

Train this system

A320 air conditioning and pressurisation in the Knowledge Trainer

185 questions on this system, each explained from the FCOM with its source, and the trainer brings back what you got wrong until it sticks.

Train this system

Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The live aircraft is the platform's systems model, the same one the ECAM Trainer and the flight deck run. Aircraft differ by type, engine and options: your aircraft's FCOM and your operator's procedures always come first. How we write and check these pages.

Know this system

Learn it from the FCOM, one question at a time.

The Knowledge Trainer has 2,517 questions across all 18 systems, each explained from the FCOM. Start free today, or open everything with A320 Knowledge+.

For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.