A320 fire protection
Two loops that must agree while both work, a pushbutton that isolates an engine, bottles the crew fires, and one APU bottle that fires itself on the ground. Built up one piece at a time, with the live FIRE panel to try.
- In short
- What does the fire protection system protect?
- What is the simplest way to picture engine and APU fire detection?
- When does a loop signal become a fire warning?
- What does the ENG FIRE pushbutton do when it is pushed?
- How many bottles are there, and who fires them?
- What does the APU do by itself when it catches fire?
- How is smoke in the holds, the lavatories and the avionics bay detected?
- How does the crew test the fire protection?
- In an engine fire, what is automatic and what is the crew's?
- What differs between the A319, A320 and A321, ceo and neo?
Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy
In short
The A320 detects fire and overheat on its engines and APU, detects smoke in the cargo compartments, the lavatories and the avionics bay, and has fire extinguishing for the cargo compartments, the engines, the APU and the lavatory waste bins.
- Detection: each engine and the APU has two identical loops, A and B, and a Fire Detection Unit; with both loops working, both must detect the fire.
- Engines: two bottles each, discharged by the flight crew from the FIRE panel once the ENG FIRE pushbutton is pushed.
- APU: one bottle; on the ground, an APU fire shuts the APU down and discharges the bottle automatically.
- Cargo: smoke detectors on two loops, and, in the FCOM's cargo description, one bottle with a discharge head for each compartment, fired from the CARGO SMOKE panel.
- Lavatories and avionics bay: smoke detection; each lavatory waste bin has its own automatic extinguishing.
Sources FCOM DSC-26-10 DESCRIPTION / FCOM DSC-26-40-10 WASTEBIN FIRE EXTINGUISHING / FCOM DSC-26-20-10 FIRE DETECTION / FCOM DSC-26-20-10 EXTINGUISHING / FCOM DSC-26-20-20 / FCOM DSC-26-30-10 SMOKE DETECTION / FCOM DSC-26-40-10 SMOKE DETECTION / FCOM DSC-26-50-10 SMOKE DETECTION / FCOM DSC-26-50-10 FIRE EXTINGUISHING
What does the fire protection system protect?
The FCOM's list gives three jobs: fire and overheat detection, smoke detection, and fire extinguishing.
Fire and overheat detection covers the engines and the APU. Smoke detection covers the cargo compartments, the lavatories and the avionics bay. Fire extinguishing covers the cargo compartments, the engines, the APU and the lavatories, where it is the waste bins that extinguish themselves. On top of the fixed systems, the aircraft carries portable fire extinguishers in the cockpit and in the cabin.
Sources FCOM DSC-26-10 DESCRIPTION / FCOM DSC-26-40-10 WASTEBIN FIRE EXTINGUISHING
What is detected, and what is extinguished
What is the simplest way to picture engine and APU fire detection?
A teaching image first, not the FCOM's term: picture two detection lines side by side, loop A and loop B. The FCOM gives each engine and the APU two identical loops, mounted in parallel, and a Fire Detection Unit (FDU) that receives their signals.
The loops are made of sensing elements. On an engine there are three or four of them, as installed, in the pylon nacelle, the engine core and the fan section; the APU has one, in its compartment. A heated element signals the FDU, and as soon as loops A and B both detect a temperature above a preset level, the fire warning is triggered.
Sources FCOM DSC-26-20-10 FIRE DETECTION
Step 1: two loops and a detection unit
When does a loop signal become a fire warning?
The FDU processes every warning and caution that comes from the sensing elements. The FCOM gives four ways to a fire warning: both loops send a fire signal; one loop sends a fire signal and the other has failed; breaks occur in both loops within 5 s of each other, which the FCOM calls the flame effect; or a test is performed on the FIRE panel.
With both loops operative it is an AND: both must agree. With either loop inoperative it becomes an OR, and the remaining loop alone can trigger the warning. So a fault in one loop, a break or a loss of electrical supply, does not affect the warning system, and as the FCOM puts it, "the unaffected loop still protects the aircraft."
A loop-fault caution appears if one loop fails, if both fail, or if the FDU fails. ENG 1(2) FIRE LOOP A(B) FAULT puts that loop on the STATUS page's inoperative systems; ENG 1(2) FIRE DET FAULT triggers when both loops or the FDU are inoperative, and its STATUS lists that engine's fire detection, FIRE DET 1(2), as inoperative. The APU has the same pair: APU FIRE LOOP A(B) FAULT and APU FIRE DET FAULT.
Sources FCOM DSC-26-20-10 FIRE DETECTION AND DETECTION FAULT LOGIC / FCOM DSC-26-20-10 FIRE DETECTION / FCOM PRO-ABN-ENG ENG 1(2) FIRE DET FAULT / FCOM PRO-ABN-ENG ENG / FCOM PRO-ABN-ENG ENG 1(2) FIRE LOOP A(B) FAULT / FCOM PRO-ABN-APU APU FIRE DET FAULT / FCOM PRO-ABN-APU APU / FCOM PRO-ABN-APU APU FIRE LOOP A(B) FAULT
From loop signals to warning or caution
What does the ENG FIRE pushbutton do when it is pushed?
Each engine has a guarded ENG FIRE pushbutton on the FIRE panel, normally in. Its red lights come on whenever that engine's fire warning is active, whatever the pushbutton's position. A second red FIRE light, on the ENG MASTER panel on the pedestal, identifies the engine to be shut down.
Pushed, the pushbutton is released and sends an electrical signal that, for that engine, silences the aural fire warning, arms the extinguisher squibs, closes the low pressure fuel valve, the hydraulic fire shut off valve, the engine bleed valve and the pack flow control valve, cuts off the FADEC power supply and deactivates the IDG.
It works with the ENG MASTER lever, which at OFF closes the LP and HP fuel valves; the FIRE pushbutton closes the LP valve too, and adds the rest. Pushing it is also what wakes the bottles: both AGENT pushbuttons of that engine become active when the ENG FIRE pushbutton is released, and their SQUIB lights come on white to show which to press.
Sources FCOM DSC-26-20-20 / FCOM PRO-ABN-ENG ENG
Step 2: what the ENG FIRE pushbutton isolates
Push the ENG 1 FIRE pushbutton
In flight with an engine 1 fire warning. Thrust lever 1 is at idle and its master lever already off. The FIRE panel below works, with the HYD page beside it.


-
Predict The master lever has already closed the LP and HP fuel valves. When you push ENG 1 FIRE, what happens to green's fire valve on the HYD page?
Try it Lift the guard and push ENG 1 FIRE.
Green's fire valve now shows amber across the line: fully closed. The master lever closed the LP and HP fuel valves; the hydraulic fire shut off valve, the bleed and pack valves, the FADEC supply and the IDG come from the pushbutton. The SQUIB lights come on white on both AGENT pushbuttons.
Sources FCOM DSC-29-20 ECAM HYD PAGE / FCOM DSC-29-10-20 FIRE SHUTOFF VALVES / FCOM PRO-ABN-ENG ENG / FCOM DSC-26-20-20
-
Predict You now press AGENT 1. What does its amber DISCH light tell you?
Try it Press AGENT 1.
A brief push discharges the bottle, and DISCH comes on amber when it has lost its pressure: it reports the bottle, not the fire. Here the fire is not put out, so the red light stays; on the aircraft it stays on until the fire is extinguished, whatever the pushbutton's position.
Sources FCOM DSC-26-20-20 / FCOM PRO-ABN-ENG ENG
How many bottles are there, and who fires them?
Each engine has two fire extinguisher bottles, discharged by electrically operated squibs, each squib with a dual electrical supply. The APU has one bottle with two squibs. For the cargo compartments, the FCOM's description gives one bottle with two discharge heads, one for each compartment, supplying one nozzle in the forward hold and two in the aft hold. Its cargo bottle fault alert, though, names a bottle 1 and a bottle 2 for the forward or aft compartment, and neither unit gives a type.
For the engines and the APU the crew fires from the FIRE panel, with a brief push on an AGENT pushbutton once its FIRE pushbutton is released. For the cargo, the crew presses that compartment's DISCH pushbutton on the CARGO SMOKE panel, which ignites its squib; within 60 s the amber DISCH light shows the bottle fully discharged. The lavatory waste bins need no one: each has its own automatic extinguishing.
The timing of an engine bottle has a reason. In flight the ECAM has the crew discharge the first agent after 10 s, a delay that "allows N1 to decrease, reducing nacelle ventilation", so the agent works better, and the ECAM counts the seconds down. The second agent is for a fire warning that is still there 30 s after the first.
Sources FCOM DSC-26-20-10 EXTINGUISHING / FCOM DSC-26-50-10 FIRE EXTINGUISHING / FCOM PRO-ABN-SMOKE / FCOM PRO-ABN-SMOKE SMOKE / FCOM DSC-26-20-20 / FCOM DSC-26-50-20 / FCOM DSC-26-40-10 WASTEBIN FIRE EXTINGUISHING / FCOM PRO-ABN-ENG ENG
Step 3: the bottles, and who fires them
What does the APU do by itself when it catches fire?
The FCOM places the APU's automatic shutdown and discharge on the ground. It lists them among the ground operation safety devices: on the ground the APU may run without cockpit crew supervision. When an APU fire is detected on the ground, the APU shuts down and its bottle discharges automatically, while a horn sounds in the nose gear bay. The APU FIRE light's description gives the timing: the bottle discharges automatically 3 s after the fire warning appears.
Fire is one of the reasons the FCOM gives for an automatic APU shutdown, marked "on ground only". In flight the ECAM has the crew push the APU FIRE pushbutton, which shuts the APU down, silences the aural warning, arms the squib, closes the LP fuel valve, shuts off the APU fuel pump, closes the APU bleed valve and the crossbleed valve and deactivates the APU generator. The AGENT then becomes active, with its SQUIB light white. The ECAM says not to restart the APU.
The ground crew has its own control: the APU SHUT OFF pushbutton shuts the APU down without its cooling cycle and silences the external horn.
Sources FCOM DSC-49-10-20 GROUND OPERATION SAFETY DEVICES / FCOM DSC-26-20-10 EXTINGUISHING / FCOM DSC-26-20-20 / FCOM DSC-49-20 / FCOM PRO-ABN-APUF APU FIRE / FCOM DSC-49-10-20 CONTROLS
An APU fire in flight
In flight with the APU running. Press the failure, watch what the aircraft does by itself, then do what the ECAM asks first.


Failure Start an APU fire
The APU FIRE pushbutton lights red and the E/WD shows APU FIRE in red, with LAND ASAP. The FCOM marks the automatic shutdown for fire "on ground only", and in flight the ECAM gives the pushbutton and the agent to the crew: here the APU still has its fuel.
Sources FCOM DSC-26-20-20 / FCOM PRO-ABN-APUF APU FIRE / FCOM DSC-49-20
Try it Lift the guard and push APU FIRE, as the ECAM asks.
The APU LP fuel valve closes and the aural warning stops; the APU shuts down, and the red light stays as long as a fire is detected. SQUIB comes on white on the APU AGENT, now active; the ECAM has the crew discharge it after 10 s, to let the airflow decrease.
Sources FCOM PRO-ABN-APUF APU FIRE / FCOM DSC-26-20-20
How is smoke in the holds, the lavatories and the avionics bay detected?
The cargo compartments use the same two-loop idea with smoke detectors. They sit in the ceiling panel cavities, each on one of two detection loops, and report to a two-channel Smoke Detection Control Unit (SDCU) or a Cabin Intercommunication Data System (CIDS) with a smoke detection function, which passes the signal to the ECAM. Smoke in one cavity gives the cargo smoke warning if both its detectors detect smoke, or one does and the other is inoperative. The red SMOKE light of that compartment comes on with the ECAM warning.
Some of the response is automatic: when the warning comes, the cargo isolation valves close and the extraction fan stops, on aircraft fitted with them (the FCOM's option list shows the cargo isolation valves and extraction fan on some A320ceo). The rest is the crew's. The ECAM has the crew switch the cabin fans off and discharge the agent into that compartment, and set the isolation valve off only "IF NOT AUTOMATICALLY CLOSED". On the ground the agent line sits under IF AFT (FWD) CRG CLOSED, and the crew orders the ground crew not to open that door until the passengers have disembarked and fire services are present. The SMOKE warning may stay after the discharge: the gases are not evacuated, and the detectors also sense the agent.
Each lavatory has one smoke detector in its air extraction duct. It signals the SDCU or the CIDS, which passes it to the Flight Warning Computer for a warning in the cockpit and in the cabin. The waste bins extinguish themselves; the SMOKE LAVATORY SMOKE procedure is about communication: contact with the cabin crew to follow the smoke's origin and dissipation, and the SMOKE/FUMES/AVNCS SMOKE QRH procedure considered.
The avionics bay has one smoke detector in the air extraction duct of its ventilation. Smoke detected for more than 5 s gives AVIONICS SMOKE with the single chime and MASTER CAUTION, the SMOKE light in the GEN 1 LINE pushbutton, and the BLOWER and EXTRACT FAULT lights. Its procedure is the SMOKE/FUMES/AVNCS SMOKE procedure: the FCTM sums up its philosophy as anticipating the diversion and the immediate actions, then, if the source is not isolated at once, initiating the diversion before identifying and fighting it.
Sources FCOM DSC-26-50-10 SMOKE DETECTION / FCOM DSC-26-50-20 / FCOM DSC-21-40-20 / FCOM GEN / FCOM GEN GENERAL INFORMATION / FCOM PRO-ABN-SMOKE SMOKE / FCTM PR-AEP-SMOKE CARGO SMOKE / FCOM DSC-26-40-10 SMOKE DETECTION / FCOM DSC-26-40-10 WASTEBIN FIRE EXTINGUISHING / FCOM PRO-ABN-SMOKE SMOKE LAVATORY SMOKE / FCOM DSC-26-30-10 SMOKE DETECTION / FCOM PRO-ABN-AVNCS AVIONICS SMOKE / FCOM PRO-ABN-SMOKE / FCTM PR-AEP-SMOKE SMOKE/FUMES/AVNCS SMOKE QRH PROCEDURE
Where the smoke signals go
Smoke in a hold, smoke in a lavatory
The cruise, nothing detected yet. The CARGO SMOKE panel is below, between CARGO VENT and VENTILATION. Press a failure and compare what lights with what the E/WD asks.


Failure Smoke in the aft hold
The red AFT SMOKE light comes on with the red warning and LAND ASAP. The isolation valve line reads IF NOT AUTOMATICALLY CLOSED: the live aircraft has aft cargo ventilation, whose controller closes the aft isolation valves and stops the extraction fan by itself when aft smoke is detected, so that line needs no push.
Sources FCOM DSC-26-50-20 / FCOM PRO-ABN-SMOKE / FCOM PRO-ABN-SMOKE SMOKE / FCOM DSC-21-40-20 / FCOM DSC-21-40-30 OVERHEAD PANEL
Try it Lift the guard and press AFT DISCH.
The squib fires the bottle into the aft hold. Here both DISCH lights come on at once: the live aircraft has the one bottle of the FCOM's description; on the aircraft the amber DISCH light comes on within 60 s, once the bottle is fully discharged. The crew should expect the SMOKE warning to stay. CAB FANS, on the VENTILATION panel below, is the ECAM's other action.
Sources FCOM DSC-26-50-10 FIRE EXTINGUISHING / FCOM DSC-26-50-20 / FCOM PRO-ABN-SMOKE SMOKE
Failure Smoke in a lavatory
Here no overhead light comes on: the FCOM gives the warning in the cockpit and the cabin through the Flight Warning Computer. The E/WD's one line is CKPT/CAB COM, ESTABLISH; the procedure has no pushbutton to press, and the waste bin's extinguisher is automatic.
Sources FCOM DSC-26-40-10 SMOKE DETECTION / FCOM DSC-26-40-10 WASTEBIN FIRE EXTINGUISHING / FCOM PRO-ABN-SMOKE SMOKE LAVATORY SMOKE / FCOM PRO-ABN-SMOKE SMOKE
How does the crew test the fire protection?
The FCTM's rule for the overhead panel is a light out philosophy: "The systems are ready and fit to fly." A fire system is shown to work with TEST pushbuttons.
The ENG 1(2) FIRE TEST pushbutton tests that engine's detection and extinguishing. Pressed, it sounds the continuous repetitive chime, flashes the MASTER WARNING lights and puts ENG FIRE on the ECAM. On the FIRE panel the ENG FIRE pushbutton lights red, the SQUIB lights come on white if the discharge supplies are available, and the DISCH lights come on amber. On the pedestal the FIRE lights come on red, except with a loop A fault on engine 1 or a loop B fault on engine 2.
The APU FIRE TEST does the same for the APU. On the ground, holding it for more than 3 s may shut the APU down automatically. On the ground with only the batteries supplying the network, the SQUIB and DISCH lights come on without the ECAM warnings, and the red light comes on only partly. A separate TEST pushbutton-switch checks the APU's fire warning, automatic extinguishing and shutdown circuits, with the APU MASTER switch ON; a running APU shuts down.
The cargo TEST pushbutton, pressed for at least 3 s and until released, tests the smoke detectors in sequence, lights the red SMOKE lights twice with the ECAM warning, closes the isolation valves of the cargo ventilation system where fitted, and lights the amber DISCH lights.
Sources FCOM DSC-26-20-20 / FCOM DSC-26-50-20 / FCTM AOP-10-20-30 DARK COCKPIT CONCEPT FOR OVERHEAD PANEL
What the ENG FIRE TEST lights
In an engine fire, what is automatic and what is the crew's?
The ECAM carries the procedure; this is only its logic. The aircraft detects and warns by itself: ENG 1(2) FIRE on the ECAM, with the red lights on the FIRE panel and the pedestal. The bottles are another matter: "The flight crew controls the discharge of the fire extinguisher bottles from the FIRE panel in the cockpit."
Isolating the engine is the crew's work too: the ENG MASTER lever closes the LP and HP fuel valves, and the ENG FIRE pushbutton closes the other valves, cuts the FADEC supply and arms the squibs. The automatic help is in the timing: the ECAM counts the 10 s before the first agent down by itself. In flight the warning brings LAND ASAP, and the ECAM says not to attempt a restart.
On the ground the aim changes. The aircraft has to be stopped (full reverse may be used) and evacuated: the lines that isolate the engine wait for the aircraft to stop, both agents share one line, AGENT 1+2, with no delay written, and the procedure leads into the emergency evacuation. Only VHF 1 is available on batteries for the call to ATC. If the warning disappears, for example when the first bottle puts the fire out, the FCTM says the procedure can be stopped.
One fire gets none of this. A tailpipe fire is inside the engine, at start or shutdown, and gives no cockpit alert. The FCTM says not to use the ENG FIRE pushbutton, which would cut the FADEC's supply and stop the dry crank, nor the bottles, which do not extinguish an internal fire.
Sources FCOM PRO-ABN-ENG (IN FLIGHT) / FCOM DSC-26-20-20 / FCOM DSC-26-20-10 EXTINGUISHING / FCOM PRO-ABN-ENG ENG / FCOM PRO-ABN-ENG (ON GROUND) / FCTM AOP-30-30 / FCTM PR-AEP-ENG ENGINE TAILPIPE FIRE
Automatic, or the crew's
An engine fire warning
The cruise, both engines running. Press the failure and see what the aircraft does by itself, and what it leaves to the crew.


Failure Start an engine 1 fire
ENG 1 FIRE lights red on the FIRE panel and the E/WD shows the red warning, LAND ASAP and the first lines for the crew. Here the warning closes nothing, and engine 1 keeps its fuel and its bleed; the FCOM gives those closures to the master lever and the pushbutton. Its first two lines, the thrust lever and the master lever, are on the pedestal, not drawn here; the pushbutton is the section above.
Sources FCOM PRO-ABN-ENG (IN FLIGHT) / FCOM PRO-ABN-ENG ENG / FCOM DSC-26-20-20
What differs between the A319, A320 and A321, ceo and neo?
The FCOM units for the engine and APU loops and their logic, the bottles, the FIRE panel and the fire alerts carry no type applicability: one description for the A319ceo, A320ceo, A320neo and A321neo. The differences it marks are in the cargo and smoke parts, and some are fit, not type:
- Cargo smoke detectors: two in the forward hold and four in the aft hold on the A319ceo, A320ceo and A320neo; four forward and six aft on the A321neo. The dual loop principle is the same.
- Smoke detection unit: an SDCU or a CIDS with a smoke detection function, as fitted.
- Cargo bottles: the FCOM's cargo description gives one bottle with two discharge heads; its SMOKE FWD(AFT) CRG BTL 1(2) FAULT alert, shown as fitted in the option list, names a bottle 1 and a bottle 2. Neither carries a type.
- Cargo ventilation: the cargo isolation valves and extraction fan that close and stop on a cargo smoke warning are shown in the option list on some A320ceo.
- SMOKE AFT CARGO SMOKE STATUS: one version, for some aircraft, also lists L+R CAB FAN as inoperative; the version with no type given lists AFT CRG VENT and AFT CRG HEAT only.
Sources FCOM DSC-26-20-10 FIRE DETECTION / FCOM DSC-26-20-10 EXTINGUISHING / FCOM DSC-26-20-10 FIRE DETECTION AND DETECTION FAULT LOGIC / FCOM DSC-26-20-20 / FCOM PRO-ABN-ENG (IN FLIGHT) / FCOM PRO-ABN-APUF APU FIRE / FCOM GEN / FCOM GEN GENERAL INFORMATION / FCOM DSC-26-40-10 SMOKE DETECTION / FCOM DSC-26-50-10 SMOKE DETECTION / FCOM DSC-26-50-10 FIRE EXTINGUISHING / FCOM PRO-ABN-SMOKE SMOKE / FCOM PRO-ABN-SMOKE ABNORMAL AND EMERGENCY PROCEDURES / FCOM PRO-ABN-SMOKE
Go further
The studio's own lessons on this system, played step by step on the panel and the SD page, and the Interactive Flight Deck at the FIRE panel.
In the ECAM Trainer
Work these fire protection failures as a crew, line by line against the FCOM, in the ECAM Trainer. Red: a warning; amber: a caution.
Videos
Key abbreviations
- FDU
- Fire Detection Unit
- SDCU
- Smoke Detection Control Unit
- CIDS
- Cabin Intercommunication Data System
- FWC
- Flight Warning Computer
- FADEC
- Full Authority Digital Engine Control System
- IDG
- Integrated Drive Generator
- APU
- Auxiliary Power Unit
- ECAM
- Electronic Centralised Aircraft Monitoring
- LP
- Low Pressure
- HP
- High Pressure
- ATC
- Air Traffic Control
- N1
- Low Pressure Rotor Speed (in %)
- CRC
- Continuous Repetitive Chime
- QRH
- Quick Reference Handbook
- FCTM
- Flight Crew Techniques Manual
- VHF
- Very High Frequency
- SD
- System Display

A320 fire protection in the Knowledge Trainer
103 questions on this system, each explained from the FCOM with its source, and the trainer brings back what you got wrong until it sticks.
Train this systemWritten in our own words from the FCOM and the FCTM; each part names the units it rests on. The live aircraft is the platform's systems model, the same one the ECAM Trainer and the flight deck run. Aircraft differ by type, engine and options: your aircraft's FCOM and your operator's procedures always come first. How we write and check these pages.
Learn it from the FCOM, one question at a time.
The Knowledge Trainer has 2,517 questions across all 18 systems, each explained from the FCOM. Start free today, or open everything with A320 Knowledge+.
For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.
Related
- A320 engines and APUTwo FADEC-run turbofans and a self-contained APU, built up one idea at a time, with the live pedestal, APU panel, E/WD and SD pages to try…
- A320 air conditioning and pressurisationTwo packs cool the air, trim air warms each zone, and one outflow valve holds the cabin altitude, built up one piece at a time, with the…
- A320 pneumatics and bleed airTwo engines, the APU and a ground connection feeding one crossbleed duct, built up one piece at a time, with the live AIR COND panel and…
- A320 oxygen systemHigh-pressure oxygen feeding a mask at every cockpit seat, cabin masks that drop from their containers, fed by chemical generators, and a…
- All 18 A320 systemsWhat each system is, and where to study it