A320 engines and APU
Two FADEC-run turbofans and a self-contained APU, built up one idea at a time, with the live pedestal, APU panel, E/WD and SD pages to try each idea on.
- In short
- What do the engines and the APU give the aircraft?
- What is the simplest way to picture a turbofan?
- Who controls the engine: the pilot or the FADEC?
- How do the thrust levers and the autothrust share the work?
- How does an engine start, and what does the crew do?
- What does the APU do, and how is it started?
- What does the crew see?
- What happens when one engine fails?
- Why is losing both engines a different problem?
- What differs between the A319, A320 and A321, ceo and neo?
Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy
In short
The A320 has two high bypass turbofans, each run by its own two-channel FADEC, and an APU that supplies bleed air and electrical power. The FCOM this page uses describes the CFM56-5B on the A319ceo and A320ceo and the LEAP-1A on the A320neo and A321neo, and many of their figures differ.
- Each engine also drives a hydraulic pump (green on engine 1, yellow on engine 2) and a generator.
- The FADEC controls fuel flow, start, ignition and the reverser, and sets the thrust limit for each lever detent.
- The thrust levers move only by hand; the autothrust commands no more than the lever position allows, unless alpha floor is active.
- Starts are automatic, under the FADEC's authority, with a manual start if one fails.
- The APU supplies bleed air and electrical power on the ground, and in flight backs up the electrical system and the air conditioning.
Sources FCOM DSC-70-05 OVERVIEW / FCOM DSC-70-05 / FCOM DSC-70-20 GENERAL / FCOM DSC-49-10-10 GENERAL / FCOM DSC-29-10-20 GREEN SYSTEM PUMP / FCOM DSC-29-10-20 YELLOW SYSTEM PUMPS / FCOM DSC-70-10 ACCESSORY GEARBOX / FCOM DSC-70-20 FUNCTIONS / FCOM DSC-70-30-20 THRUST LEVERS / FCOM DSC-70-30-40 AUTOMATIC MODE / FCOM DSC-70-80-40 AUTOMATIC STARTING / FCOM DSC-70-80-40 MANUAL STARTING

What do the engines and the APU give the aircraft?
Thrust first. But each engine is also a power station. Its accessory gearbox, driven by the HP shaft, turns the oil pump, the main fuel pump, an engine-driven hydraulic pump, a generator, the FADEC's own alternator and the pneumatic starter.
Engine 1's pump pressurises the green hydraulic system and engine 2's the yellow, and the engine-driven generators are the aircraft's primary source of electrical power. That is why the FCTM advises keeping a malfunctioning engine running in flight when no procedure asks for a shutdown: "Even at idle, the engine powers the hydraulic, electric, and bleed systems."
The APU, a self-contained unit, is the third source of bleed air and electrical power.
Sources FCOM DSC-70-10 ACCESSORY GEARBOX / FCOM DSC-29-10-20 GREEN SYSTEM PUMP / FCOM DSC-29-10-20 YELLOW SYSTEM PUMPS / FCTM PR-AEP-ENG ENGINE ABNORMAL RESPONSE / FCOM DSC-49-10-10 GENERAL
What an engine's gearbox drives
What is the simplest way to picture a turbofan?
Follow the air. The fan and LP compressor compress it, then the flow splits: most goes around the core and gives most of the thrust. The rest is compressed again by the HP compressor, burnt with fuel in the combustion chamber, and drives the HP and then the LP turbine.
Two shafts, two speeds to watch. N1 is the fan's rotation speed and N2 the HP rotor's, both in percent on the E/WD. The FADEC uses N1 to compute the thrust, and N1 and N2 to control and monitor the engine.
Which engine, though, matters for every figure on this page. The FCOM describes two: two CFM International CFM56-5B on the A319ceo and A320ceo, and two CFM International LEAP-1A on the A320neo and A321neo. Even their stages differ: a single-stage HP turbine on the CFM56-5B, two stages on the LEAP-1A. IAE and PW1100G engines appear in this FCOM only in passing, so this page gives no figure for them.
Sources FCOM DSC-70-10 ENGINE / FCOM DSC-70-10 COMBUSTION CHAMBER / FCOM DSC-70-05 OVERVIEW / FCOM DSC-70-05 / FCOM DSC-70-10 LP COMPRESSOR TURBINE ASSEMBLY / FCOM DSC-70-10 HP COMPRESSOR TURBINE ASSEMBLY / FCOM DSC-22_30-90 GENERAL / FCOM DSC-28-10-60 / FCOM PRO-ABN-ENG ENG
Step 1: the air's path through the engine
Who controls the engine: the pilot or the FADEC?
The pilot asks; the FADEC decides how. Each engine has its own full authority digital engine control, on the fan case, with two channels: one active, one in standby that takes over by itself if the other fails. The Engine Interface Unit (EIU) passes it the aircraft data it needs.
Its work is the whole engine: fuel flow, the idle setting, protection against N1 and N2 overspeed, the thrust limits, the automatic start, the reverser and the parameters sent to the cockpit. The LEAP-1A's FADEC adds protection against stall and flame-out, Thrust Control Malfunction Accommodation (TCMA) and protection against a bowed rotor during ground starts.
Idle is one example of the FADEC choosing. In flight it selects approach idle, which lets the engine accelerate rapidly to go-around thrust, with the flaps extended on the CFM56-5B, and in CONF 3 or FULL or with the gear down on the LEAP-1A.
Sources FCOM DSC-70-20 GENERAL / FCOM DSC-70-20 FUNCTIONS / FCOM DSC-70-20 IDLE CONTROL
Step 2: the FADEC between the crew and the engine
How do the thrust levers and the autothrust share the work?
The thrust levers move only by hand: the autothrust never moves them. They have three stops and three detents: REV MAX, REV IDLE, IDLE (0), CL, FLX/MCT and TO/GA. In a detent the FADEC selects that detent's rating limit; between two, the higher one. The E/WD shows each lever's position as a blue circle on the N1 gauge.
In manual mode each lever position is an N1. On the ground FLX/MCT gives flexible takeoff thrust if a flex temperature above TAT has been entered, MCT otherwise; TOGA always gives maximum takeoff thrust.
With the autothrust active, the FMGC computes the thrust, "limited to the value corresponding to the thrust lever position (unless the alpha-floor mode is activated)." Armed, it becomes active when both levers are set between CL and IDLE, or one lever between MCT and IDLE with one engine inoperative.
Behind IDLE is reverse: the crew lifts the reverse lever at the idle stop to bring the thrust lever back. The reversers are hydraulic, green on engine 1 and yellow on engine 2, and FADEC-controlled: pivoting blocker doors on the CFM56-5B, translating sleeves on the LEAP-1A. Deployment also needs both main gears compressed and a reverse signal from at least one SEC.
Sources FCOM DSC-70-30-20 THRUST LEVERS / FCOM DSC-70-30-30 THRUST RATING LIMIT / FCOM DSC-70-90-20 / FCOM DSC-70-30-40 MANUAL MODE / FCOM DSC-70-30-40 AUTOMATIC MODE / FCOM DSC-22_30-90 GENERAL / FCOM DSC-22_30-90 A/THR ACTIVATION / FCOM DSC-22_30-90 / FCTM AOP-10-30-10 THRUST/AUTOTHRUST / FCOM DSC-70-70 GENERAL / FCOM DSC-70-70 ACTUATION LOGIC
Step 3: the thrust lever's six positions
Select reverse on the live pedestal
Just landed, both engines at idle. The thrust levers work: watch the top right of the E/WD and the N1 gauges.


-
Predict Bring thrust lever 1 back to REV IDLE. What appears on engine 1's N1 gauge on the E/WD?
Try it Bring thrust lever 1 to REV IDLE.
Here REV shows on the N1 gauge and turns green at once. On the aircraft REV is amber while the reverser is unlocked and green once it is fully deployed on the ground, which takes less than 2 s on the CFM56-5B and about 2 s on the LEAP-1A.
Sources FCOM DSC-70-90-40 / FCOM DSC-70-70 GENERAL
-
Predict Now thrust lever 2 as well. What does the thrust rating at the top right of the E/WD read?
Try it Bring thrust lever 2 to REV IDLE.
Here, with both levers in the reverse sector, the rating mode reads MREV, maximum reverse, and with the reversers selected the N1 limit value goes.
Sources FCOM DSC-70-90-40
-
Try it Now pull both levers to REV MAX.
Reverse works best at high speed, so the FCTM has it selected right after main gear touchdown. Below 70 kt its efficiency falls fast, and below 60 kt REV MAX may stall the engine, so the FCTM recommends REV IDLE at 70 kt, except in an emergency, and stowing at taxi speed before leaving the runway.
Sources FCTM PR-NP-SOP-250 DECELERATION
How does an engine start, and what does the crew do?
Air turns the engine first. Each engine has an air turbine starter fed from the pneumatic system through a start valve (on the ground, APU bleed air for example), and the FADEC opens that valve electrically.
An automatic start is under the full authority of the FADEC. The crew turns the ENG MODE selector to IGN/START, then sets the ENG MASTER lever ON: the LP fuel valve and the start valve open, and the FADEC adds ignition and opens the HP fuel valve as N2 rises. At the end, the crew sets the selector back to NORM.
The FADEC watches the start for a failed light-up, a hot start, a stall or low start air pressure, among others (the list differs by engine). On the ground it aborts the start, dry cranks the engine to clear the fuel vapours and controls any new attempt. On the LEAP-1A it may also motor the engine dry for up to 60 s before a ground start, against a bowed rotor.
If an automatic start fails, the crew can use a manual start: ENG MODE to IGN/START, ENG MAN START ON, then the master lever ON. The FADEC then has limited control and the crew monitors the engine; in flight the FADEC has no authority to abort it, and on the ground only if the start EGT limit is exceeded before 50 % N2, or, on the LEAP-1A, after a starter shaft shear or a dual N2 sensor failure.
In flight, with the engine running, ENG MODE at IGN/START gives continuous ignition, and the green IGNITION memo shows it.
Sources FCOM DSC-70-80-40 GENERAL / FCOM DSC-49-10-10 GENERAL / FCOM DSC-70-80-40 AUTOMATIC STARTING / FCOM DSC-70-80-40 / FCOM DSC-70-20 FUNCTIONS / FCOM DSC-70-80-40 MANUAL STARTING / FCOM DSC-70-90-10 ENG MAN START PANEL / FCOM DSC-70-90-10 ON ON / FCOM DSC-70-80-30 CONTINUOUS IGNITION / FCOM DSC-70-90-50
The start figures, engine by engine
Start the engines on the live pedestal
On the stand, the APU running and supplying the aircraft. The ENG MODE selector and the ENG MASTER levers work: watch the E/WD.


-
Try it Turn the ENG MODE selector to IGN/START.
On the aircraft this brings the ENGINE page to the SD, makes all the engine parameters available and closes the pack valves, which reopen after 30 s if no ENG MASTER lever is set ON.
Sources FCOM DSC-70-80-40
-
Predict Set ENG MASTER 2 ON. Once engine 2 runs, which AC bus does its generator supply?
Try it Set ENG MASTER 2 ON.
Here the engine runs as soon as the lever is ON; on the aircraft the FADEC takes it through the sequence above. Once it runs, its gearbox turns the yellow pump and generator 2. Here generator 2 takes AC BUS 2 and the APU generator keeps AC BUS 1, the split the FCOM's bus tie rule describes: one contactor is closed when an engine generator supplies its own AC bus and the APU generator the other side.
Sources FCOM DSC-70-80-40 / FCOM DSC-29-10-20 YELLOW SYSTEM PUMPS / FCOM DSC-70-10 ACCESSORY GEARBOX / FCOM DSC-24-20 OVERHEAD PANEL
-
Try it Set ENG MASTER 1 ON.
Now each engine generator supplies its own side, and green has its engine pump. The engine generators come first in the priority order, ahead of external power and the APU generator.
Sources FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-29-10-20 GREEN SYSTEM PUMP
What does the APU do, and how is it started?
The APU is a single-shaft gas turbine that drives a generator and produces bleed air. A full-authority Electronic Control Box (ECB) sequences its start and shutdown, watches its speed and temperature and shuts it down automatically when needed. It takes fuel from the left fuel feed line.
Two pushbuttons start it. MASTER SW powers it and opens the air intake flap and the fuel isolation valve. START then engages the electric starter once the flap is fully open; ignition comes 1.5 s later, and both stop at 60 % N. Above 95 % AVAIL comes on and the APU can supply bleed air and electrical power. It can start on the aircraft's batteries.
Its two products each have a rule. With APU BLEED ON and N above 95 %, its air supplies the pneumatic system and the engine bleed valves close; with the X BLEED selector at AUTO, the crossbleed valve opens too. Its generator connects only if the external power line contactor is open: external power comes before the APU generator.
Switched off with MASTER SW after supplying bleed air, it keeps running 60 to 120 s to cool. The ECB shuts it down by itself for a long list of reasons, among them overspeed, EGT overtemperature, low oil pressure and, on the ground only, a fire: the FAULT light comes on in MASTER SW and a caution appears.
Sources FCOM DSC-49-10-20 APU ENGINE / FCOM DSC-49-10-20 ELECTRONIC CONTROL BOX / FCOM DSC-49-10-20 FUEL SYSTEM / FCOM DSC-49-10-10 GENERAL / FCOM DSC-49-10-20 STARTER / FCOM DSC-49-20 / FCOM DSC-36-10-30 GENERAL / FCOM DSC-36-10-40 GENERAL / FCOM DSC-36-20 OVERHEAD PANEL / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-49-10-20 GROUND OPERATION SAFETY DEVICES
What the APU supplies, and when
The APU panel and the APU page
On the ground, the APU running with AVAIL lit, and external power connected. MASTER SW works: watch the APU page.


-
Predict External power is connected. If you switch the APU off now, do the AC buses lose power?
Try it Switch MASTER SW off.
External power has priority over the APU generator, so the buses never depended on it. Here the APU stops at once. On the aircraft the ON and AVAIL lights go out, the APU runs 60 to 120 s to cool if its bleed air was in use, and the air intake flap closes at 7 %.
Sources FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-49-20
Failure Shut the APU down automatically
Here FAULT comes on in MASTER SW and AVAIL goes out: the ECB has shut the APU down. On the aircraft the caution APU AUTO SHUT DOWN appears; it triggers for an automatic shutdown for any reason other than a fire.
Sources FCOM DSC-49-20 / FCOM PRO-ABN-APU APU AUTO (EMER) SHUT DOWN
Try it Switch MASTER SW off, as the ECAM asks.
MASTER SW OFF is the procedure's one action.
Sources FCOM PRO-ABN-APU APU
What does the crew see?
On the E/WD, the primary parameters: N1 with its amber limit mark and the lever's blue circle, EGT with its amber limit and red line, N2, fuel flow, and the thrust rating mode with its N1 limit. REV appears with a reverser unlocked or deployed, AVAIL after a successful start, IDLE with both engines at idle in flight.
On the ENGINE page of the SD: oil quantity, pressure and temperature, N1 and N2 vibrations, the igniters, the start valve and the starter inlet pressure. On the APU page: N and EGT, the APU generator, the bleed valve and pressure, FLAP OPEN and FUEL LO PR.
The limits on those dials belong to the engine. The EGT red line is 950 °C on the CFM56-5B and 1 060 °C on the LEAP-1A; the amber limit 915 °C (725 °C during a ground start) and 1 025 °C (750 °C). The N1 red limit is 104 % and 101 %, the N2 red limit 105 % and 116.5 %. The live aircraft here is an A320ceo, with the CFM56-5B figures.
Sources FCOM DSC-70-90-20 / FCOM DSC-70-90-40 / FCOM DSC-49-20 ECAM APU PAGE / FCOM DSC-49-20 / FCOM DSC-49-20 APU
Where each parameter is shown
What happens when one engine fails?
ENG 1(2) FAIL triggers when an engine's core speed is below idle with its master lever ON and its fire pushbutton not pushed. A flame-out shows as a fast fall of EGT, N2 and fuel flow, then N1. In flight, after LAND ASAP (and, in one version, for some aircraft, the separate shaft shear and thrust malfunction cases), the procedure's in-flight lines begin with ENG MODE SEL IGN, which confirms the FADEC's immediate relight attempt, and the thrust lever to IDLE.
Only if the engine has not relit 30 s after the alert does the ECAM ask for the master lever OFF: in some versions it sits under IF NO ENG RELIGHT AFTER 30 S; in another, for other aircraft, under a further IF NO RELIGHT line as well. Then damage decides, suspected from two or more signs such as EGT rising fast above the red line or strong vibration: with damage, the fire pushbutton and agent 1; without, a relight can be considered.
Low oil pressure is handled by checking first. ENG 1(2) OIL LO PR triggers below 13 psi on the CFM56-5B, and below a threshold rising with N2 from 17.4 psi to 29 psi on the LEAP-1A. A red pressure on the ENGINE page with no alert points to a faulty transducer, and the engine may be kept running while the crew monitors its other parameters.
Losing an engine costs its generator and its hydraulic pump. With the APU off, the other generator takes both AC buses, and if engine 1 is the one lost, the PTU keeps green pressurised from yellow.
Sources FCOM PRO-ABN-ENG ENG 1(2) FAIL / FCOM PRO-ABN-ENG ENG / FCOM PRO-ABN-ENG ENG 1(2) OIL LO PR / FCOM PRO-ABN-ENG ABNORMAL AND EMERGENCY PROCEDURES / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-29-10-20 GREEN SYSTEM PUMP / FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU)
Fail an engine
In the cruise, both engines running, the ELEC page on the SD. Press a failure, read the E/WD, then do what the ECAM asks on the ENG panel.



Failure Flame out engine 1
Engine 1 has stopped. Generator 1 drops off line and generator 2 supplies both AC buses, as the ELEC page shows; green has lost its engine pump and the PTU pressurises it from yellow.
Sources FCOM PRO-ABN-ENG ENG 1(2) FAIL / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-29-10-20 GREEN SYSTEM PUMP / FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU)
Try it Turn ENG MODE to IGN/START; then, with no relight after 30 s, set ENG MASTER 1 OFF.
The crew also sets the thrust lever to IDLE, on the pedestal (not drawn here). The master lever OFF is conditional: it comes only when there is no relight 30 s after the alert.
Sources FCOM PRO-ABN-ENG ENG
Failure Lose engine 1's oil pressure
The engine is still running: generator 1 and the green pump carry on. The ECAM's first line is a check of the oil pressure on the ENGINE page.
Sources FCOM PRO-ABN-ENG ABNORMAL AND EMERGENCY PROCEDURES / FCOM PRO-ABN-ENG ENG
Try it The pressure is confirmed low: set ENG MASTER 1 OFF.
The crew sets the thrust lever to IDLE first, on the pedestal (not drawn here). In one version, for some aircraft, both lines sit under IF OIL PR < 13 PSI; in the other the procedure goes from the check straight to idle and master lever OFF.
Sources FCOM PRO-ABN-ENG ABNORMAL AND EMERGENCY PROCEDURES / FCOM PRO-ABN-ENG ENG
Failure Lose engine 2's FADEC
The live aircraft shows engine 2's values as amber XX, its own reading. On the aircraft ENG 2 FADEC FAULT triggers when both channels are lost, and with the engine indications lost the crew checks the engine on other pages such as HYD, ELEC or BLEED: here yellow and generator 2 are still running.
Sources FCOM PRO-ABN-ENG ENG 1(2) FADEC FAULT / FCOM PRO-ABN-ENG ENG
Why is losing both engines a different problem?
With both engines gone, the FCTM names the main results: an emergency electrical configuration and the loss of green and yellow. The RAT deploys by itself, pressurises blue and drives the emergency generator, which supplies the AC ESS and DC ESS bus bars.
ENG ALL ENGINES FAILURE triggers when all engines have failed in flight. Its purpose is to secure the automatic RAT extension and emergency generator connection, which the crew does with EMER ELEC PWR MAN ON, and then to send the crew to the ALL ENG FAIL QRH procedure. On the way it gives the optimum relight speed, 300 kt/M 0.77 in one version and 270 kt/M 0.77 in the other, for different aircraft, and has the crew start the APU below FL 250.
The QRH procedure favours the windmill relight; if several attempts fail, below FL 200 the APU bleed can assist a relight, one engine at a time.
Sources FCTM PR-AEP-ENG / FCOM PRO-ABN-ENG ENG ALL ENGINES FAILURE / FCOM PRO-ABN-ENG ENG / FCOM PRO-ABN-ENG / FCOM PRO-ABN-ENG ABNORMAL AND EMERGENCY PROCEDURES
What is left when both engines stop
Lose both engines
In the cruise, both engines running, the ELEC page on the SD. Press the failure and read the E/WD.


Failure Flame out both engines
The RAT is out, blue runs on it and the emergency generator is on line; green and yellow are lost. There is nothing to press here: the EMER ELEC PWR MAN ON pushbutton the ECAM asks for is on another panel, and its purpose is to secure what the live aircraft has already done.
Sources FCOM PRO-ABN-ENG ENG / FCOM PRO-ABN-ENG / FCTM PR-AEP-ENG
What differs between the A319, A320 and A321, ceo and neo?
The levers and detents, the FADEC's two channels, the start controls and the APU are described alike for all four types; the engine's figures and some of its functions are not.
- Engine: two CFM56-5B on the A319ceo and A320ceo, two LEAP-1A on the A320neo and A321neo, each with its own limits (above).
- Oil: OIL LO PR below 13 psi on the CFM56-5B; from 17.4 psi at idle to 29 psi at high thrust on the LEAP-1A.
- Reversers: pivoting blocker doors on the CFM56-5B, translating sleeves on the LEAP-1A.
- A320neo and A321neo only: the LEAP-1A's bowed rotor dry motoring and TCMA against uncontrollable high thrust (on the ground, at takeoff and in approach).
- ENG 1(2) FUEL LEAK: an alert given only in the versions for some aircraft; it compares the two engines' fuel flow or fuel used.
- Relight speed after ENG ALL ENGINES FAILURE: 300 kt/M 0.77 in one version, 270 kt/M 0.77 in the other, for different aircraft.
Sources FCOM DSC-70-20 GENERAL / FCOM DSC-70-30-10 GENERAL / FCOM DSC-70-90-20 / FCOM DSC-70-80-10 GENERAL / FCOM DSC-49-10-10 GENERAL / FCOM DSC-70-05 OVERVIEW / FCOM DSC-70-05 / FCOM DSC-70-90-40 / FCOM PRO-ABN-ENG ENG 1(2) OIL LO PR / FCOM PRO-ABN-ENG ENG / FCOM DSC-70-70 GENERAL / FCOM DSC-70-80-40 / FCOM DSC-70-30-40 THRUST CONTROL MALFUNCTION LOGIC / FCOM PRO-ABN-ENG ENG 1(2) FUEL LEAK / FCOM PRO-ABN-ENG
Go further
The studio's own lessons on this system, played step by step on the panel and the SD page, and the Interactive Flight Deck at the APU panel.
In the ECAM Trainer
Work these engines and APU failures as a crew, line by line against the FCOM, in the ECAM Trainer. Red: a warning; amber: a caution.
Limitations
- EGT limit, takeoff and go-aroundA319ceo, A320ceo · CFM56-5BIncludes TOGA, FLEX and DERATEFCOM LIM-ENG · THRUST SETTING/EGT LIMITS950 °C
- EGT limit, MCTA319ceo, A320ceo · CFM56-5BFCOM LIM-ENG · THRUST SETTING/EGT LIMITS915 °C
- EGT limit, startingA319ceo, A320ceo · CFM56-5BThe limitations table gives no separate figure for a start in flight. The EGT limit line shows 725 °C during a ground start and 915 °C in all other casesFCOM LIM-ENG · THRUST SETTING/EGT LIMITS725 °C
- EGT limit, takeoff and go-aroundA320neo, A321neo · LEAP-1AIncludes TOGA, FLEX and DERATEFCOM LIM-ENG · THRUST SETTING/EGT LIMITS1 060 °C
- EGT limit, MCTA320neo, A321neo · LEAP-1AFCOM LIM-ENG · THRUST SETTING/EGT LIMITS1 025 °C
- EGT limit, starting on groundA320neo, A321neo · LEAP-1AFCOM LIM-ENG · THRUST SETTING/EGT LIMITS750 °C
- EGT limit, starting in flightA320neo, A321neo · LEAP-1AFCOM LIM-ENG · THRUST SETTING/EGT LIMITS875 °C
- Max time at takeoff/go-around thrust, all engines operativeSame in both engine tablesFCOM LIM-ENG · THRUST SETTING/EGT LIMITS5 min
- Max time at takeoff/go-around thrust, one engine inoperativeSame in both engine tablesFCOM LIM-ENG · THRUST SETTING/EGT LIMITS10 min
- Maximum N1A319ceo, A320ceo · CFM56-5BFCOM LIM-ENG · SHAFT SPEEDS104 %
- Maximum N2A319ceo, A320ceo · CFM56-5BFCOM LIM-ENG · SHAFT SPEEDS105 %
- Maximum N1A320neo, A321neo · LEAP-1AFCOM LIM-ENG · SHAFT SPEEDS101 %
- Maximum N2A320neo, A321neo · LEAP-1AFCOM LIM-ENG · SHAFT SPEEDS116.5 %
- Oil temperature, max continuousSame for both enginesFCOM LIM-ENG · OIL140 °C
- Oil temperature, max transientMax 15 min in the transient range; same for both enginesFCOM LIM-ENG · OIL155 °C (15 min)
- Oil temperature, minimum for startingSame for both enginesFCOM LIM-ENG · OIL-40 °C
- Oil temperature, minimum before takeoffA319ceo, A320ceo · CFM56-5BFCOM LIM-ENG · OIL-10 °C
- Oil temperature, minimum before takeoffA320neo, A321neo · LEAP-1AFCOM LIM-ENG · OIL19 °C
- Minimum oil quantityA319ceo, A320ceo · CFM56-5BFCOM LIM-ENG · OIL9.5 qt + estimated consumption
- Minimum oil quantityA320neo, A321neo · LEAP-1AFCOM LIM-ENG · OILHighest of 10.6 qt, or 8.9 qt + estimated consumption
- Minimum oil pressureA320neo, A321neo · LEAP-1AFCOM LIM-ENG · OIL17.4 PSI
- Start attempts in one standard automatic start (one cycle)Same for both enginesFCOM LIM-ENG · STARTERUp to 3
- Starter: pause between successive ground start cyclesA319ceo, A320ceo · CFM56-5BFCOM LIM-ENG · STARTER20 s
- Starter: cooling period required after how many failed cyclesA319ceo, A320ceo · CFM56-5BFCOM LIM-ENG · STARTER4 failed cycles (15 min cooling)
- Starter must not be run when N2 is aboveA319ceo, A320ceo · CFM56-5BFCOM LIM-ENG · STARTER20 %
- Starter: pause between successive ground start cyclesA320neo, A321neo · LEAP-1AFCOM LIM-ENG · STARTER60 s
- Starter: cooling period required after how many failed cyclesA320neo, A321neo · LEAP-1AFCOM LIM-ENG · STARTER3 failed cycles (15 min cooling)
- Starter must not be run when N2 is aboveA320neo, A321neo · LEAP-1AFCOM LIM-ENG · STARTER63 %
- Max reverse should not be used belowIdle reverse permitted down to aircraft stopFCOM LIM-ENG · REVERSE THRUST70 kt
- Max crosswind for engine startA320neo, A321neo · LEAP-1AFCOM LIM-ENG · CROSSWIND OPERATION ON GROUND45 kt
- Consecutive APU start attempts before a waiting periodFCOM LIM-APU · GENERAL3
- Wait after three consecutive APU start attemptsFCOM LIM-APU · GENERAL60 min
- APU maximum N speedFCOM LIM-APU107 %
- APU max EGT for start, below 35 000 ftAbove 35 000 ft: 1 120 °CFCOM LIM-APU1 090 °C
- APU max EGT for start, above 35 000 ftFCOM LIM-APU1 120 °C
- APU max EGT, runningFCOM LIM-APU675 °C
- APU bleed: max altitude to assist engine startFCOM LIM-APU · AUXILIARY POWER UNIT20 000 ft
Videos
Key abbreviations
- FADEC
- Full Authority Digital Engine Control System
- EIU
- Engine Interface Unit
- N1
- Low Pressure Rotor Speed (in %)
- N2
- High Pressure Rotor Speed (in %)
- EGT
- Exhaust Gas Temperature
- FF
- Fuel Flow
- HP
- High Pressure
- LP
- Low Pressure
- TCMA
- Thrust Control Malfunction Accommodation
- MCT
- Maximum Continuous Thrust
- FLX
- Flexible
- TOGA
- Takeoff - Go-Around
- ECB
- Electronic Control Box (APU)
- APU
- Auxiliary Power Unit
- E/WD
- Engine/Warning Display
- SD
- System Display
- SEC
- Spoiler Elevator Computer, Secondary
- FMGC
- Flight Management and Guidance Computer
- FMGS
- Flight Management and Guidance System
- A/THR
- Autothrust
- PTU
- Power Transfer Unit (Hydraulic)
- RAT
- Ram Air Turbine
- ECAM
- Electronic Centralised Aircraft Monitoring
- QRH
- Quick Reference Handbook
- FCTM
- Flight Crew Techniques Manual
- TAT
- Total Air Temperature

A320 engines and APU in the Knowledge Trainer
176 questions on this system, each explained from the FCOM with its source, and the trainer brings back what you got wrong until it sticks.
Train this systemWritten in our own words from the FCOM and the FCTM; each part names the units it rests on. The live aircraft is the platform's systems model, the same one the ECAM Trainer and the flight deck run. Aircraft differ by type, engine and options: your aircraft's FCOM and your operator's procedures always come first. How we write and check these pages.
Learn it from the FCOM, one question at a time.
The Knowledge Trainer has 2,517 questions across all 18 systems, each explained from the FCOM. Start free today, or open everything with A320 Knowledge+.
For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.
Related
- A320 fuel systemFuel in the wings and a centre tank, each engine fed from its own side, built up one piece at a time, with the live FUEL panel and page to…
- A320 electrical systemTwo generators that never work in parallel, a bus tie between them and the essential buses that can outlive them all, built up one piece at…
- A320 hydraulic systemThree hydraulic systems that never share a drop of fluid, built up one piece at a time, and the live HYD panel and SD page to try every…
- A320 fire protectionTwo loops that must agree while both work, a pushbutton that isolates an engine, bottles the crew fires, and one APU bottle that fires…
- A320 pneumatics and bleed airTwo engines, the APU and a ground connection feeding one crossbleed duct, built up one piece at a time, with the live AIR COND panel and…
- All 18 A320 systemsWhat each system is, and where to study it