A320 hydraulic system
Three hydraulic systems that never share a drop of fluid, built up one piece at a time, and the live HYD panel and SD page to try every idea on.
- In short
- Why does the A320 need hydraulics at all?
- What is the simplest way to picture it?
- Where does each system get its pressure?
- What does the PTU do, and when?
- Which system moves what?
- What does the crew see, and touch?
- What happens when a pump or a reservoir fails?
- Why is losing two systems so serious?
- What differs between the A319, A320 and A321, ceo and neo?
Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy
In short
The A320 has three continuously operating hydraulic systems, green, blue and yellow, at 3 000 psi, each with its own reservoir. Fluid never passes from one to another.
- Green: one pump, driven by engine 1.
- Blue: an electric pump, and the RAT in an emergency (2 500 psi).
- Yellow: a pump driven by engine 2, an electric pump, and a hand pump for the cargo doors.
- The PTU lets green and yellow pressurise each other when their pressures are more than 500 psi apart.
- One system lost changes little in the cockpit; two lost is an emergency.
Sources FCOM DSC-29-10-10 GENERAL / FCOM DSC-29-10-20 GREEN SYSTEM PUMP / FCOM DSC-29-10-20 BLUE SYSTEM PUMPS / FCOM DSC-29-10-20 YELLOW SYSTEM PUMPS / FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM DSC-29-10-20 RAM AIR TURBINE (RAT) / FCTM PR-AEP-HYD DUAL HYDRAULIC FAILURES

Why does the A320 need hydraulics at all?
Start with what the pilot moves. On the A320 every flight control surface is electrically controlled and hydraulically actuated: the sidestick sends an electrical order to a computer, and a hydraulic actuator moves the surface. The stabiliser and the rudder can also be controlled mechanically.
The surfaces are not the only users. The hydraulic distribution also feeds the slats and flaps, the landing gear, the normal and alternate brakes, the nosewheel steering, the engine reversers and the yaw dampers, and the blue system can drive the emergency generator.
Three separate systems supply that pressure.
Sources FCOM DSC-27-10-10 BASIC PRINCIPLE / FCOM DSC-29-10-30 DISTRIBUTION / FCOM DSC-29-10-10 GENERAL
What hydraulic pressure moves
What is the simplest way to picture it?
Picture three separate circuits side by side, each painted its own colour: green, blue and yellow. Each has its own reservoir and its own pumps, and each operates continuously at a normal pressure of 3 000 psi.
Now the one rule to remember: hydraulic fluid cannot be transferred from one system to another. A leak in green can empty green, but it can never drain blue or yellow. Everything else on this page is about how the three systems get their pressure, and how one can help another without ever sharing its fluid.
Sources FCOM DSC-29-10-10 GENERAL / FCTM PR-AEP-HYD HYDRAULIC GENERATION PARTICULARITIES
Step 1: three systems, one pump each
Where does each system get its pressure?
Add the pumps one at a time. Green has one pump, driven by engine 1. Yellow has one pump driven by engine 2, plus an electric pump, plus a hand pump that lets the crew operate the cargo doors when no electrical power is available.
Blue is the odd one: its normal pump is electric, not engine-driven. At AUTO it runs whenever AC power is available in flight, and on the ground once one engine is running (or when the BLUE PUMP OVRD pushbutton on the maintenance panel has been pressed). For an emergency, blue has a second pump, turned by the ram air turbine (RAT).
The RAT drops out by itself if AC BUS 1 and AC BUS 2 are both lost with the aircraft above 100 kt, and the crew can extend it at any time with the RAT MAN ON pushbutton. Once out, it can be stowed only on the ground. Driven by the RAT, blue runs at 2 500 psi and turns the emergency generator through a hydraulic motor.
Sources FCOM DSC-29-10-20 GREEN SYSTEM PUMP / FCOM DSC-29-10-20 YELLOW SYSTEM PUMPS / FCOM DSC-29-10-20 BLUE SYSTEM PUMPS / FCOM DSC-29-20 OVERHEAD PANEL / FCOM DSC-29-10-10 GENERAL / FCOM DSC-29-10-20 RAM AIR TURBINE (RAT) / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS
Step 2: every source of pressure
Switch the pumps yourself
The aircraft in the cruise, all three systems normal. The HYD panel below works: every press changes the schematic above it.


-
Predict Blue has one pump in normal operation. If you switch it off, can another system keep blue pressurised?
Try it Switch the blue ELEC PUMP off.
Blue is gone. Its electric pump is its only pump in normal operation, and the PTU links green and yellow only, so it cannot lend blue anything. Only blue's emergency pump, driven by the RAT, could.
Sources FCOM DSC-29-10-20 BLUE SYSTEM PUMPS / FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU)
-
Try it Set the blue ELEC PUMP back to AUTO.
In flight, AUTO is all the blue pump needs, as long as AC power is available.
Sources FCOM DSC-29-20 OVERHEAD PANEL
-
Try it Extend the RAT with RAT MAN ON.
The crew can extend the RAT at any time with this pushbutton; once out, it can only be stowed on the ground.
Sources FCOM DSC-29-10-20 RAM AIR TURBINE (RAT) / FCOM DSC-29-20 OVERHEAD PANEL
What does the PTU do, and when?
Now join two of the circuits, without breaking the rule. The power transfer unit (PTU) sits between green and yellow and lets either system pressurise the other. Power crosses, fluid never does.
It needs no one to switch it on. At AUTO it comes into action by itself when the pressure difference between green and yellow is greater than 500 psi, in either direction. On the ground it has extra conditions: it is inhibited during the first engine start, and during use of the cargo door hand pump and for 40 s after. In flight, as the FCTM puts it, this lets it cover "the loss of one engine or one engine driven pump cases." On the ground it is also how green can be pressurised with the engines stopped, from the yellow electric pump.
Blue has no such link: its emergency source is the RAT, and yellow has its own electric pump.
Sources FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM DSC-29-10-10 GENERAL / FCTM PR-AEP-HYD HYDRAULIC GENERATION PARTICULARITIES / FCOM DSC-29-10-20 YELLOW SYSTEM PUMPS / FCOM DSC-29-20 OVERHEAD PANEL / FCOM DSC-32-10-30 PROXIMITY DETECTORS ON SHOCK ABSORBERS / FCOM DSC-29-10-20 BLUE SYSTEM PUMPS
Step 3: the PTU between green and yellow
Watch the PTU take over
Both engines are running. Predict first, then press the button: watch the PTU on the schematic and its arrow on the HYD page.



-
Predict If you switch ENG 1 PUMP off, what happens to the green system?
Try it Switch ENG 1 PUMP off.
Green's own pump is off, its pressure falls, and once it is more than 500 psi below yellow the PTU runs and pressurises green from yellow. The HYD PTU memo tells the crew it is running.
Sources FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM DSC-29-20 MEMO DISPLAY
-
Try it Switch ENG 1 PUMP back on.
With both engine pumps running, the pressure difference is no longer above 500 psi, and the PTU stops by itself.
Sources FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM DSC-29-20 OVERHEAD PANEL
-
Predict Now the PTU is off and you switch ENG 2 PUMP off. What happens to yellow?
Try it Switch the PTU off, then ENG 2 PUMP off.
Without the PTU nothing can pass green's power to yellow, and the yellow electric pump is off, so yellow loses its pressure.
Sources FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM DSC-29-20 OVERHEAD PANEL
-
Try it Switch the yellow ELEC PUMP on.
The yellow electric pump can pressurise yellow on its own. On the ground with the engines stopped it lets yellow be used, and in flight the ECAM has the crew switch it on in some dual failures when yellow was lost through its engine pump.
Sources FCOM DSC-29-10-20 YELLOW SYSTEM PUMPS / FCOM PRO-ABN-HYD HYD
Which system moves what?
The easiest way to learn the share of the work is to ask what each loss costs, as the STATUS page lists it.
- Losing green costs spoilers 1 and 5, normal braking and the autobrake, gear retraction, reverser 1 and yaw damper 1, and makes the slats and flaps slow.
- Losing blue costs spoiler 3 and slows the slats; with a blue reservoir low level the emergency generator is lost too.
- Losing yellow costs spoilers 2 and 4, nosewheel steering, reverser 2 and yaw damper 2, and slows the flaps.
Sources FCOM PRO-ABN-HYD HYD / FCOM PRO-ABN-HYD
Step 4: what each system moves
What does the crew see, and touch?
On the overhead HYD panel: ENG 1 PUMP and ENG 2 PUMP, the guarded BLUE ELEC PUMP at AUTO, the spring-loaded YELLOW ELEC PUMP, the PTU at AUTO and RAT MAN ON. Each pump's FAULT light covers low reservoir level, reservoir overheat, low reservoir air pressure and low pump pressure, and pump overheat for the electric pumps.
On the HYD page of the SD: each system's pressure and name, amber below 1 450 psi; each reservoir's quantity; LO AIR PRESS and OVHT under the reservoirs; the fire valves; the PTU with arrows showing which way it is pushing; and the RAT and electric pump states.
The PTU needs no selection: at AUTO it is armed and runs by itself, and the HYD PTU memo, in green, tells the crew when it is running.
Sources FCOM DSC-29-20 OVERHEAD PANEL / FCOM DSC-29-20 ECAM HYD PAGE / FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM DSC-29-20 MEMO DISPLAY
The panel and the HYD page, together
The same aircraft, as the crew sees it: the HYD panel and the HYD page. Try it and watch the page.


-
Try it Switch ENG 2 PUMP off and watch the PTU on the HYD page.
The HYD page shows the PTU running and which way it is pushing, here from green to yellow.
Sources FCOM DSC-29-20 ECAM HYD PAGE
-
Try it Switch ENG 2 PUMP back on.
Both engine pumps on, the pressure difference is no longer above 500 psi, and the PTU is idle again.
Sources FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM DSC-29-20 OVERHEAD PANEL
What happens when a pump or a reservoir fails?
A pump failure first. HYD G ENG 1 PUMP LO PR triggers when the pump outlet pressure falls to 1 750 psi or below. If the PTU works, it keeps green pressurised from yellow, and the crew switches the failed pump off; if it does not, green is lost.
A reservoir failure is different, and the reason is worth knowing. After a green or yellow RSVR LO LVL, a RSVR OVHT, or a RSVR LO AIR PR with the pressure fluctuating, the ECAM has the crew switch the PTU off, and the FCTM says without delay. A running PTU may overheat two minutes later, and "a PTU overheat may lead to the loss of the second hydraulic circuit." One lost system must not take a second with it.
Losing one system changes little in handling, but the landing capability drops to CAT 3 SINGLE.
Sources FCOM PRO-ABN-HYD (PTU OPERATIVE) / FCOM PRO-ABN-HYD HYD G ENG 1 PUMP LO PR / FCOM PRO-ABN-HYD (PTU INOPERATIVE) / FCOM PRO-ABN-HYD HYD / FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM PRO-ABN-HYD HYD G RSVR LO AIR PR / FCOM PRO-ABN-HYD HYD G RSVR LO LVL / FCOM PRO-ABN-HYD / FCOM PRO-ABN-HYD HYD G RSVR OVHT / FCOM PRO-ABN-HYD ABNORMAL AND EMERGENCY PROCEDURES / FCTM PR-AEP-HYD HYDRAULIC GENERATION PARTICULARITIES / FCTM PR-AEP-HYD DUAL HYDRAULIC FAILURES
Fail it yourself
Press a failure, see what the aircraft does by itself, then do what the ECAM asks.




Failure Fail the green engine pump
The green pump's pressure falls and the PTU takes over green from yellow: green stays pressurised.
Sources FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM PRO-ABN-HYD (PTU OPERATIVE)
Try it Switch ENG 1 PUMP off, as the ECAM asks.
With the PTU working, the crew switches the failed pump off, as the ECAM asks, and STATUS lists it as inoperative; green carries on through the PTU.
Sources FCOM PRO-ABN-HYD HYD G ENG 1 PUMP LO PR / FCOM PRO-ABN-HYD HYD
Failure Drop the green reservoir level
Green's reservoir is below 3.5 l and green is lost: the gear will be extended by gravity and the landing distance procedure applies.
Sources FCOM PRO-ABN-HYD HYD G RSVR LO LVL / FCOM PRO-ABN-HYD HYD / FCOM PRO-ABN-HYD ABNORMAL AND EMERGENCY PROCEDURES
Try it Switch the PTU and ENG 1 PUMP off, as the ECAM asks.
The PTU goes off to protect yellow from a PTU overheat: blue and yellow carry on.
Sources FCOM PRO-ABN-HYD / FCTM PR-AEP-HYD HYDRAULIC GENERATION PARTICULARITIES
Why is losing two systems so serious?
With two systems gone, every user of those two is affected at once. HYD G+B SYS LO PR, HYD G+Y SYS LO PR and HYD B+Y SYS LO PR each trigger when both systems are at or below 1 450 psi, and each brings a red LAND ASAP.
In all three the autopilot is lost (AP 1+2 is on each INOP SYS list), but the FD and A/THR remain; after HYD G+B SYS LO PR, the STATUS has the crew set the A/THR off if the systems are not recovered. Each STATUS also limits the speed to 320 kt/M 0.77.
The gear needs care, because the reason differs. After G+B and G+Y, green is lost, and L/G RETRACT is on the INOP SYS list. After B+Y, green still works, yet if the systems are not recovered the STATUS still has the gear extended by gravity, "to preserve green system integrity". All three STATUS pages call for the gravity extension when the systems are not recovered, and the FCTM's table of remaining systems gives no gear retraction for a go-around in any of the three.
The FCTM treats each as a complex procedure: hand flown, the QRH summary after the ECAM, and a careful briefing.
What remains differs a great deal between the three, and that is what the diagram shows. After losing green and yellow, the stabiliser and the flaps are lost and braking relies on the yellow accumulator, without anti-skid. Losing blue and yellow keeps normal law.
Sources FCOM PRO-ABN-HYD HYD B+Y SYS LO PR / FCOM PRO-ABN-HYD HYD / FCOM PRO-ABN-HYD HYD G+B SYS LO PR / FCOM PRO-ABN-HYD HYD G+Y SYS LO PR / FCTM PR-AEP-HYD DUAL HYDRAULIC FAILURES / FCOM PRO-ABN-HYD / FCTM PR-AEP-HYD REMAINING SYSTEMS
What each dual loss leaves
What differs between the A319, A320 and A321, ceo and neo?
The architecture is the same on the A319ceo, A320ceo, A320neo and A321neo: the same pumps, PTU, RAT, reservoirs and HYD page. Among the differences the FCOM shows: an alert threshold, and what some STATUS pages ask for.
- Green and yellow reservoir overheat: in one version, for some aircraft, the alert triggers at 98 °C and resets at 93 °C; in the other it triggers at 93 °C and resets at 88 °C.
- HYD G ENG 1 PUMP LO PR: one STATUS version, for some aircraft, adds the landing distance procedure; the other lists only the inoperative pump.
- Approach speed after HYD G+B SYS LO PR: VREF +25 kt in one version, VREF +30 kt in the other, for different aircraft.
- Approach speed after HYD G+Y SYS LO PR: VREF +25 kt, VREF +30 kt or VREF +35 kt, in three versions for different aircraft.
Sources FCOM DSC-29-10-10 GENERAL / FCOM DSC-29-20 OVERHEAD PANEL / FCOM DSC-29-20 ECAM HYD PAGE / FCOM PRO-ABN-HYD HYD G ENG 1 PUMP LO PR / FCOM PRO-ABN-HYD HYD / FCOM PRO-ABN-HYD HYD G RSVR OVHT / FCOM PRO-ABN-HYD HYD Y RSVR OVHT / FCOM PRO-ABN-HYD
Go further
The studio's own lessons on this system, played step by step on the panel and the SD page, and the Interactive Flight Deck at the HYD panel.
In the ECAM Trainer
Work these hydraulic system failures as a crew, line by line against the FCOM, in the ECAM Trainer. Red: a warning; amber: a caution.
Videos
Key abbreviations
- PTU
- Power Transfer Unit (Hydraulic)
- RAT
- Ram Air Turbine
- HP
- High Pressure
- ECAM
- Electronic Centralised Aircraft Monitoring
- SD
- System Display
- NWS
- Nosewheel Steering
- AP
- Autopilot
- FD
- Flight Director
- A/THR
- Autothrust
- RSVR
- Reservoir
- VAPP
- Approach Speed
- VREF
- Landing Reference Speed
- FCTM
- Flight Crew Techniques Manual
- QRH
- Quick Reference Handbook

A320 hydraulic system in the Knowledge Trainer
108 questions on this system, each explained from the FCOM with its source, and the trainer brings back what you got wrong until it sticks.
Train this systemWritten in our own words from the FCOM and the FCTM; each part names the units it rests on. The live aircraft is the platform's systems model, the same one the ECAM Trainer and the flight deck run. Aircraft differ by type, engine and options: your aircraft's FCOM and your operator's procedures always come first. How we write and check these pages.
Learn it from the FCOM, one question at a time.
The Knowledge Trainer has 2,517 questions across all 18 systems, each explained from the FCOM. Start free today, or open everything with A320 Knowledge+.
For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.
Related
- A320 flight controlsSeven computers between the sidestick and the surfaces, built up one piece at a time, and the live FLT CTL panel and F/CTL page to switch…
- A320 landing gear and brakesA gear moved by green, two brake systems on two hydraulic systems, and the computers that choose between them, built up one piece at a…
- A320 electrical systemTwo generators that never work in parallel, a bus tie between them and the essential buses that can outlive them all, built up one piece at…
- A320 engines and APUTwo FADEC-run turbofans and a self-contained APU, built up one idea at a time, with the live pedestal, APU panel, E/WD and SD pages to try…
- All 18 A320 systemsWhat each system is, and where to study it