Free to read · live

A320 electrical system

Two generators that never work in parallel, a bus tie between them and the essential buses that can outlive them all, built up one piece at a time, with the live ELEC panel and page to try each idea on.

Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy

The answer first

In short

The A320 makes three-phase 115/200 V 400 Hz AC and 28 V DC. Two engine generators and an APU generator can each supply nearly every busbar, and the generators are never connected in parallel.

  • GEN 1 and GEN 2: one per engine, each driven through an integrated drive, each supplying its own AC bus.
  • APU GEN and external power: the APU GEN can replace either or both engine generators; on the ground, either can supply the complete system.
  • DC: TR 1 and TR 2 turn AC into DC; the ESS TR stands by for the essential DC bus.
  • Two batteries, on the hot buses: when nothing else is left, they supply the DC ESS BUS and, through a static inverter, the AC ESS BUS above 50 kt.
  • Both main AC buses lost above 100 kt: the RAT extends and the blue hydraulic system drives a 5 KVA emergency generator for the essential buses.

Sources FCOM DSC-24-10-10 GENERAL / FCOM DSC-24-10-30-10 GENERAL / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-20 DC GENERATION / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-10-30-20 ON GROUND / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL

The ELEC page of the A320ceo ECAM, as the platform draws it: a healthy aircraft in the cruise
The ELEC pageAs our ECAM Trainer draws it: an A320ceo, healthy, in the cruise.

What does the electrical system have to supply?

Two kinds of power. The aircraft's main supply is three-phase AC at 115/200 V and a constant 400 Hz, and part of that AC is converted into 28 V DC for the equipment that needs DC.

In normal configuration the AC comes from generators: two driven by the engines and a third by the APU. If normal AC is not available, an emergency generator can provide AC, and if no AC is available at all, the system can turn the batteries' DC into AC. Commercial supply has secondary priority.

Sources FCOM DSC-24-10-10 GENERAL

Two kinds of power, and where each comes from

Two kinds of power, and where each comes fromTop row, left to right: generators at 115/200 V 400 Hz, the AC buses, the TRs turning AC into DC, the DC buses at 28 V. Below, dashed: the emergency generator feeding the AC ESS BUS, and the batteries feeding the DC side and, through the static inverter, the AC ESS BUS. Generators115/200 V, 400 HzAC busesTRsAC into DCDC buses28 VEMER GENfor the AC ESS BUSSTAT INVDC into AC ESS BUSBatteriesDC
Generators make AC for the AC buses; transformer rectifiers (TRs) turn part of it into 28 V DC. Dashed: the back-ups, an emergency generator for the AC ESS BUS, and the batteries, whose DC a static inverter can turn into AC for the AC ESS BUS.

What is the simplest way to picture it?

Picture two sides, left and right. In normal flight GEN 1 supplies AC BUS 1 through its generator line contactor (GLC 1), and GEN 2 supplies AC BUS 2 through GLC 2. Under each AC bus its own TR makes the DC for its own DC bus: TR 1 for DC BUS 1, TR 2 for DC BUS 2.

Now the rule that shapes everything else: "The generators cannot be connected in parallel." A bus never takes power from two generators at once. When a bus loses its own generator, the bus tie contactors at AUTO give it another source instead.

Sources FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE / FCOM DSC-24-10-30-10 GENERAL / FCOM DSC-24-20 OVERHEAD PANEL

Step 1: two sides, one generator each

Step 1: two sides, one generator eachTwo columns separated by a wall. Left: GEN 1 through GLC 1 to AC BUS 1, then through TR 1 to DC BUS 1. Right: GEN 2 through GLC 2 to AC BUS 2, then through TR 2 to DC BUS 2. GLC 1GLC 2GEN 1engine 1, IDGGEN 2engine 2, IDGAC BUS 1AC BUS 2DC BUS 1through TR 1DC BUS 2through TR 2
Step 1 of 4. Each engine generator supplies its own AC bus through its line contactor, and each AC bus its own TR and DC bus. The wall: the generators are never connected in parallel.

Where does the power come from?

One source at a time. Each engine drives its own generator through an integrated drive; the panel calls the unit the IDG, integrated drive generator. Each generator can supply up to 90 KVA. A generator control unit (GCU) for each one controls its frequency and voltage, and protects the network by controlling the generator's line contactor.

The APU generator (APU GEN) is driven directly by the APU, produces the same output as an engine generator, and can replace either or both of them at any time. On the ground there is one more source: external power, through a connector near the nosewheel, which can supply all busbars.

What joins the two sides is the bus tie. At AUTO its two contactors open or close by themselves to keep AC BUS 1 and AC BUS 2 supplied, for example both closed on the APU GEN or external power alone. At OFF, both open.

Sources FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL

Step 2: every main source, and the bus tie

Step 2: every main source, and the bus tieTop row: GEN 1, APU GEN, EXT PWR and GEN 2. GEN 1 feeds AC BUS 1 and GEN 2 feeds AC BUS 2. The APU GEN and external power, dashed, feed the bus tie in the middle, which links to both AC buses. GEN 190 KVAAPU GENeither sideEXT PWRon the groundGEN 290 KVAAC BUS 1BUS TIEtwo contactorsAC BUS 2
Step 2 of 4. The APU GEN and external power sit between the two sides and reach either AC bus through the bus tie contactors. Dashed: the sources that do not supply in normal flight.
Live aircraft

Switch the generators yourself

The aircraft in the cruise, both engine generators on line, the APU not running. The ELEC panel below works: every press redraws the schematic above it.

The system's schematic as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
  1. Predict With the APU not running, if you switch GEN 1 off, what supplies AC BUS 1?

    Try it Switch GEN 1 off.

    GEN 2 now supplies both AC buses through the bus tie: one engine generator can supply the entire network except the DC BUS Entertainment. In flight with only one generator operating, the main galley is shed, and GALLEY SHED shows on the ELEC page.

    Sources FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM DSC-24-10-30-10 GENERAL / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 ECAM ELEC PAGE

  2. Try it Switch GEN 1 back on.

    Each engine generator supplies its own AC bus again, and with two generators operating the galley is no longer shed.

    Sources FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-20 OVERHEAD PANEL

  3. Predict Now set BUS TIE to OFF, then switch GEN 2 off. What happens to AC BUS 2?

    Try it Set BUS TIE to OFF, then switch GEN 2 off.

    With BUS TIE at OFF both contactors are open, so GEN 1 cannot reach the right side and AC BUS 2 is lost. The crew sometimes wants exactly that: after the loss of both generators, the ECAM has BUS TIE set to OFF for a second reset, to segregate both generator channels.

    Sources FCOM DSC-24-20 OVERHEAD PANEL / FCOM PRO-ABN-ELEC ELEC

  4. Try it Set BUS TIE back to AUTO.

    At AUTO the contactors close again to keep both AC buses supplied, and GEN 1 supplies both.

    Sources FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-10 GENERAL

Which source wins when several are available?

Sometimes more than one source could supply a bus, and the order is fixed. GEN 1 and GEN 2, when operating, have priority over the APU generator and over external power. External power has priority over the APU generator when the EXT PWR pushbutton is ON.

The APU GEN pushbutton shows the same order from the APU's side: its line contactor closes if the parameters are normal and the external power contactor is open.

The cabin's loads follow the sources. In flight, the main galley and, where fitted, the in-seat power supply and the IFE are shed when only one generator is operating; on the ground, when only one engine generator is operating, all galleys being available on the APU GEN or external power.

Sources FCOM DSC-24-10-30-10 GENERAL / FCOM DSC-24-20 OVERHEAD PANEL

Live aircraft

Watch the priorities at work

The cruise again, but this time the APU is running with APU GEN at ON, and both engine generators are on line. The ELEC panel and the ELEC page below.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
  1. Predict The APU GEN is running. If you switch GEN 1 off, what supplies AC BUS 1?

    Try it Switch GEN 1 off.

    The APU GEN takes AC BUS 1 and GEN 2 keeps its own side: a lost generator is replaced by the APU GEN if it is available, and by the other engine generator only if not. Two generators are still operating, so the galley is not shed.

    Sources FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM DSC-24-20 OVERHEAD PANEL

  2. Try it Switch the APU GEN off.

    Now the other engine generator is the remaining choice: GEN 2 supplies both sides, and the ELEC page shows GALLEY SHED.

    Sources FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM DSC-24-20 ECAM ELEC PAGE

  3. Try it Switch the APU GEN and GEN 1 back on.

    GEN 1 takes its bus back although the APU GEN is running: the engine generators, when operating, have priority over it.

    Sources FCOM DSC-24-10-30-10 GENERAL

What are the essential buses, and what keeps them alive?

When the main generators are all lost above 100 kt, the emergency generator supplies the essential buses: the AC ESS BUS and the DC ESS BUS. In normal flight AC BUS 1 supplies the AC ESS BUS, and TR 1 supplies DC BUS 1, the DC BAT BUS and the DC ESS BUS; TR 2 supplies DC BUS 2.

Each essential bus has a second road. The AC ESS FEED pushbutton at ALTN puts the AC ESS BUS on AC BUS 2, and with the AC ESS FEED auto switching, AC BUS 2 takes it over by itself when AC BUS 1 is lost. Its FAULT light comes on when the AC ESS BUS is not supplied.

So losing AC BUS 1 on an aircraft without that auto switching takes both essential buses with it: the AC ESS BUS directly, the DC ESS BUS through TR 1. AC ESS FEED at ALTN brings them back, AC BUS 2 supplying the AC ESS BUS and the ESS TR the DC ESS BUS. DC BUS 2 supplies DC BUS 1 and the DC BAT BUS automatically after 5 s.

The ESS TR is the DC side's spare. It is identical to TR 1 and TR 2, and it can power the essential DC circuit from the emergency generator, or if TR 1 or TR 2 fails. If TR 1 and TR 2 are both lost, DC BUS 1, DC BUS 2 and the DC BAT BUS go, and the ESS TR keeps the DC ESS BUS.

Sources FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-30 FAILURE OF AC BUS 1 / FCOM PRO-ABN-ELEC ELEC / FCOM DSC-24-10-20 DC GENERATION / FCOM DSC-24-10-30-30 FAILURE OF ONE TR / FCOM DSC-24-10-30-30 FAILURE OF TR 1 AND TR 2

Step 3: the essential buses and their second road

Step 3: the essential buses and their second roadTop row: AC BUS 1, the AC ESS BUS and AC BUS 2. Middle: TR 1 under AC BUS 1, the ESS TR under the AC ESS BUS, TR 2 under AC BUS 2. Bottom: DC BUS 1 and the DC BAT BUS from TR 1, the DC ESS BUS from TR 1 or, dashed, the ESS TR, and DC BUS 2 from TR 2. A dashed link from AC BUS 2 to the AC ESS BUS is marked ALTN. ALTNAC BUS 1AC ESS BUSAC BUS 2TR 1ESS TRthe spareTR 2DC BUS 1DC BAT BUSDC ESS BUSDC BUS 2
Step 3 of 4. AC BUS 1 feeds the AC ESS BUS and, through TR 1, the DC side including the DC ESS BUS. Dashed: the second road, AC BUS 2 to the AC ESS BUS with AC ESS FEED at ALTN, and the ESS TR to the DC ESS BUS.
Live aircraft

Lose a bus, lose a TR

Both generators on line. This live aircraft has no AC ESS FEED auto switching. Fail a bus or a TR, watch what the schematic does by itself, then do what the crew does.

The system's schematic as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model

Failure Fail AC BUS 1

AC BUS 1 is gone, and both essential buses with it: the AC ESS BUS was fed by AC BUS 1, the DC ESS BUS through TR 1. DC BUS 2 picks up DC BUS 1 and the DC BAT BUS, after 5 s on the aircraft.

Sources FCOM PRO-ABN-ELEC ELEC / FCOM DSC-24-10-30-30 FAILURE OF AC BUS 1

Try it Set AC ESS FEED to ALTN.

AC BUS 2 now supplies the AC ESS BUS, and the ESS TR the DC ESS BUS: the manual recovery that the AC ESS BUS FAULT procedure asks for.

Sources FCOM DSC-24-10-30-30 FAILURE OF AC BUS 1 / FCOM PRO-ABN-ELEC ELEC

Failure Fail TR 1

TR 1's contactor opens, TR 2 replaces it on the DC buses, and the ESS TR supplies the DC ESS BUS.

Sources FCOM DSC-24-10-30-30 FAILURE OF ONE TR

What do the batteries and the static inverter do?

Two batteries of 23 Ah each are permanently connected to the two hot buses. Each has a battery charge limiter (BCL), which monitors its charging and opens or closes its contactor to the DC BAT BUS.

In normal configuration the batteries are disconnected most of the time. The BCL connects them for an APU start (limited to 3 min when the emergency generator is running), to charge them when their voltage is below 26.5 V (at once on the ground, after 30 min in flight) until the charge current falls below 4 A, and when AC BUS 1 and 2 are lost below 100 kt.

When neither main AC bus is powered and the emergency generator is not supplying, the batteries carry the essentials themselves. Battery 2 supplies the DC ESS BUS. Battery 1 supplies the AC STAT INV BUS and, above 50 kt, the AC ESS BUS, through the static inverter, which turns battery 1's DC into 1 KVA of single-phase 115 V 400 Hz AC for part of the AC ESS BUS.

Above 50 kt the static inverter comes on by itself whenever only the batteries are supplying, whatever the BAT pushbuttons show; below 50 kt it needs both BAT 1 and BAT 2 on. On the parked aircraft, a cut-off logic opens the battery contactors before the batteries discharge completely.

Sources FCOM DSC-24-10-20 DC GENERATION / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-20 AC GENERATORS

What does the crew see, and touch?

On the overhead ELEC panel: BAT 1 and BAT 2 with their voltage readouts, the guarded IDG 1 and IDG 2, GEN 1, GEN 2 and APU GEN, BUS TIE, AC ESS FEED, GALY & CAB (or GALLEY), EXT PWR and, where fitted, COMMERCIAL.

Beside it, the EMER ELEC PWR panel: the guarded MAN ON pushbutton, which extends the RAT by hand; the guarded EMER GEN TEST; and GEN 1 LINE, which opens GEN 1's line contactor for the smoke drill, GEN 2 then supplying the AC BUS 1 channel through the bus tie.

On the ELEC page of the SD, the network at a glance: each engine generator and the APU GEN with its load, voltage and frequency, the IDG oil outlet temperatures, the TRs, the batteries and the busbars, normal or not powered. An engine generator turns amber above 100 % load, below 110 V or above 120 V, or below 390 Hz or above 410 Hz; a battery's voltage below 25 V or above 31 V.

On the ground, the EXT PWR pushbutton shows external power available when it is plugged in with normal parameters, and pressing it closes the external power contactor. Its ON light stays on even when the engine generators supply the aircraft.

Sources FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 OVERHEAD PANEL (CONT'D) / FCOM DSC-24-20 ECAM ELEC PAGE

Live aircraft

The panel and the ELEC page, on the ground

On the ground, engines and APU off, ground power plugged in but not selected: only the batteries are supplying.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
  1. Predict Press EXT PWR. Which busbars will external power supply?

    Try it Press EXT PWR.

    External power can supply all busbars: both AC buses through the bus tie, then the TRs and every DC bus. The ELEC page shows EXT PWR supplying, and on the ground all galleys are available on external power.

    Sources FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-30-10 GENERAL / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 ECAM ELEC PAGE

  2. Try it Switch EXT PWR off again.

    Back on the batteries. On the ground below 100 kt, with AC BUS 1 and 2 lost, the DC BAT BUS is connected to the batteries automatically.

    Sources FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL

What happens when a generator or its drive fails?

A generator first. ELEC GEN 1(2) FAULT comes up when the GCU trips its generator, or when the line contactor is open with the GEN pushbutton ON. The ECAM asks for the generator to be switched OFF then ON, and OFF if that is unsuccessful; after a differential fault, a reset has no effect after two attempts.

STATUS reminds the crew that, if available, the APU may be started and its generator used. Only if the APU GEN is not online, MAIN GALLEY is listed as inoperative and the landing capability is CAT 3 SINGLE ONLY.

The drive has its own alerts. ELEC IDG 1(2) OIL LO PR triggers on low IDG oil pressure, and ELEC IDG 1(2) OIL OVHT when the oil outlet temperature rises above 180 °C. The ELEC page pulses the temperature as an advisory above 147 °C, and at 200 °C the IDG disconnects itself thermally.

The crew disconnects the affected IDG with its guarded pushbutton, pressed until the GEN FAULT light comes on but never for more than 3 s, at or above idle if the engine is running. It is disconnected only with the engine running or windmilling; otherwise it is damaged when the engine is next started. Only maintenance personnel can reconnect it.

Sources FCOM PRO-ABN-ELEC ELEC GEN 1(2) FAULT / FCOM PRO-ABN-ELEC ELEC / FCOM DSC-24-20 OVERHEAD PANEL / FCOM PRO-ABN-ELEC CAT 3 DUAL / FCOM PRO-ABN-ELEC ELEC IDG 1(2) OIL LO PR/OVHT / FCOM DSC-24-20 ECAM ELEC PAGE

Live aircraft

Fail it yourself

Press a failure, see what the aircraft does by itself, then do what the ECAM asks.

The system's schematic as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
The E/WD as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model

Failure Fail generator 1

GEN 1's FAULT light comes on and, with the APU not running, GEN 2 takes over AC BUS 1 through the bus tie. With one generator operating in flight, GALLEY SHED shows on the ELEC page.

Sources FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 ECAM ELEC PAGE

Work this failure in the ECAM Trainer

Try it Switch GEN 1 off, as the ECAM asks once the reset has failed.

OFF is where the procedure leaves an unsuccessful reset. GEN 2 carries the network alone, and STATUS lists GEN 1 as inoperative and notes that the APU GEN may be used.

Sources FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC CAT 3 DUAL

Failure Drop IDG 1 oil pressure

The alert is about the drive, not the generator: the IDG 1 FAULT light comes on and the ELEC page shows IDG 1 in amber. Here GEN 1 stays on line until the drive is disconnected.

Sources FCOM PRO-ABN-ELEC ELEC IDG 1(2) OIL LO PR/OVHT / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 ECAM ELEC PAGE / FCOM PRO-ABN-ELEC ELEC

Work this failure in the ECAM Trainer

Try it Disconnect IDG 1 with its guarded pushbutton, as the ECAM asks.

The IDG is disconnected: its FAULT light goes out, GEN 1's FAULT light comes on, and GEN 2 takes over AC BUS 1. Only maintenance personnel can reconnect the IDG.

Sources FCOM PRO-ABN-ELEC ELEC / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR

What happens when both main AC buses are lost?

If AC BUS 1 and AC BUS 2 are both lost with the aircraft above 100 kt, the RAT extends by itself. It powers the blue hydraulic system, which drives the emergency generator through a hydraulic motor: 5 KVA of three-phase 115/200 V 400 Hz. The emergency generator supplies the AC ESS BUS, and the DC ESS BUS through the ESS TR. For the RAT's extension and the generator's coupling, about 8 s, the batteries power the emergency network.

MAN ON selects the RAT's extension by hand; the generator then couples 3 s after the RAT starts to drive it.

ELEC EMER CONFIG triggers when neither AC bus is supplied, and the ECAM shows LAND ASAP in red. Its logic: get a main generator back, an engine generator by a reset or else the APU GEN, and meanwhile make sure the emergency generator is on line, by MAN ON if it is not. The APU may be started below FL 250, but not for 45 s after the loss of both engine generators, so it cannot interfere with the emergency generator's coupling.

Speed now matters. The minimum RAT speed is 140 kt, and the FCOM adds that the RAT "is capable of supplying the EMER GEN down to 125 kt, except during flare." If the RAT stalls, or on the ground below 100 kt, nothing drives the emergency generator: the network transfers to the batteries and the static inverter (ELEC ESS BUSES ON BAT), and the AC and DC SHED ESS buses are shed. On the ground below 50 kt the AC ESS BUS is shed too, and every display unit is lost.

The FCTM sums up what is left: a distribution "designed to fly, navigate, communicate and ensure passengers comfort".

  • Fly: PFD 1 only, so the left-seat pilot flies; alternate law, then direct law with the gear down; AP, FD and A/THR lost.
  • Navigate: ND 1, FMGC 1, VOR 1/ILS 1 and DME 1.
  • Communicate: VHF 1, HF 1 and ATC 1, with RMP 1 (and RMP 2 on some aircraft).
  • Land: no nosewheel steering or anti-skid, alternate braking up to 1 000 psi, no reversers, and an approach speed of at least 140 kt to keep the emergency generator supplying.
  • On the batteries alone, more is lost, such as FAC 1 and FMGC 1.

Sources FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL (CONT'D) / FCOM PRO-ABN-ELEC ELEC EMER CONFIG / FCOM PRO-ABN-ELEC ELEC / FCTM PR-AEP-ELEC GENERAL GUIDELINES / FCOM PRO-ABN-ELEC ELEC ESS BUSES ON BAT / FCTM PR-AEP-ELEC REMAINING SYSTEMS

Step 4: the emergency network

Step 4: the emergency networkTop row: the RAT drives the blue hydraulic system, which drives the emergency generator. The emergency generator feeds the AC ESS BUS and, below it, the ESS TR, which feeds the DC ESS BUS. Dashed: battery 1 through the static inverter to the AC ESS BUS, and battery 2 to the DC ESS BUS. RATabove 100 ktBLUEhydraulic motorEMER GEN5 KVAESS TRAC ESS BUSSTAT INV1 KVABAT 2DC ESS BUSBAT 1
Step 4 of 4. With both main AC buses lost above 100 kt, the RAT drives the blue system, which drives the emergency generator; it supplies the AC ESS BUS, and the DC ESS BUS through the ESS TR. Dashed: what takes over when nothing drives the generator, battery 2 for the DC ESS BUS and battery 1 through the static inverter for part of the AC ESS BUS.
Live aircraft

Take both generators away

The cruise, both engine generators on line, the APU not running. Take both away and watch the essential side of the schematic.

The system's schematic as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
The E/WD as the live aircraft starts, drawn by the platform's systems model
  1. Predict With the APU not running, what will supply the AC ESS BUS once GEN 1 and GEN 2 are both off?

    Try it Switch GEN 1 and GEN 2 off.

    Above 100 kt with both AC buses lost, the RAT extends and the blue system drives the emergency generator, which supplies the AC ESS BUS, and the DC ESS BUS through the ESS TR. On the aircraft the batteries hold the emergency network for the 8 s or so this takes.

    Sources FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS

Failure Lose both generators

Neither AC bus is supplied: ELEC EMER CONFIG. The emergency generator takes the essential buses (on the aircraft, after about 8 s), and the procedure's first action is the generators' reset.

Sources FCOM PRO-ABN-ELEC ELEC EMER CONFIG / FCOM PRO-ABN-ELEC ELEC / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS

Work this failure in the ECAM Trainer

What differs between the A319, A320 and A321, ceo and neo?

The system's description is common to the A319ceo, A320ceo, A320neo and A321neo. Some equipment depends on the individual aircraft rather than the type: a GPCU or a GAPCU, the TR Entertainment, the AC ESS FEED auto switching and the COMMERCIAL pushbutton. The type differences below are in STATUS pages.

  • Approach speed in ELEC EMER CONFIG: VREF +10 kt (at least 140 kt) in one version; VREF +15 kt (at least 140 kt) in the other, for other aircraft.
  • Centre tank fuel in ELEC EMER CONFIG: in one version, for some aircraft, the STATUS note says it is unusable; in the other it can be transferred to the wing tanks through the jet pumps by gravity, except the last two tons.
  • After ELEC GEN 1(2) FAULT or ELEC IDG 1(2) OIL LO PR/OVHT: one STATUS version, for some aircraft, adds that, if no APU GEN is online, all the galleys are shed, and its INOP SYS list also shows CAT 3 DUAL.

Sources FCOM DSC-24-10-10 GENERAL / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-20 DC GENERATION / FCOM DSC-24-10-30-10 GENERAL / FCOM DSC-24-10-30-30 FAILURE OF AC BUS 1 / FCOM DSC-24-20 OVERHEAD PANEL / FCOM PRO-ABN-ELEC / FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC CAT 3 DUAL / FCOM PRO-ABN-ELEC ABNORMAL AND EMERGENCY PROCEDURES

Go further

The studio's own lessons on this system, played step by step on the panel and the SD page, and the Interactive Flight Deck at the ELEC panel.

Open the flight deck at this panel

In the ECAM Trainer

Work these electrical system failures as a crew, line by line against the FCOM, in the ECAM Trainer. Red: a warning; amber: a caution.

Open the ECAM Trainer

Videos

Every video on this system

Key abbreviations

AC
Alternating Current
DC
Direct Current
IDG
Integrated Drive Generator
GCU
Generator Control Unit
GLC
Generator Line Contactor
APU
Auxiliary Power Unit
RAT
Ram Air Turbine
TR
Transformer Rectifier
ESS
Essential
BCL
Battery Charge Limiter
GAPCU
Ground and Auxiliary Power Control Unit
ECAM
Electronic Centralised Aircraft Monitoring
SD
System Display
IFE
In Flight Entertainment
PFD
Primary Flight Display
ND
Navigation Display
FMGC
Flight Management and Guidance Computer
FAC
Flight Augmentation Computer
AP
Autopilot
FD
Flight Director
A/THR
Autothrust
VREF
Landing Reference Speed
FCTM
Flight Crew Techniques Manual

The FCOM's full list

Train this system

A320 electrical system in the Knowledge Trainer

119 questions on this system, each explained from the FCOM with its source, and the trainer brings back what you got wrong until it sticks.

Train this system

Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The live aircraft is the platform's systems model, the same one the ECAM Trainer and the flight deck run. Aircraft differ by type, engine and options: your aircraft's FCOM and your operator's procedures always come first. How we write and check these pages.

Know this system

Learn it from the FCOM, one question at a time.

The Knowledge Trainer has 2,517 questions across all 18 systems, each explained from the FCOM. Start free today, or open everything with A320 Knowledge+.

For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.