Free to read · live

A320 fuel system

Fuel in the wings and a centre tank, each engine fed from its own side, built up one piece at a time, with the live FUEL panel and page to try every idea on.

Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy

The answer first

In short

The A320 stores its fuel in the wings and a centre tank. Each engine is normally fed from its own side, and a cross-feed valve can join the two sides.

  • The tanks: inner and outer tanks in each wing (one wing tank on the A321neo), and a centre tank.
  • The pumps: two in each wing for its engine; if both fail, the engine can still be fed by gravity.
  • The centre tank is used before the wings: by two centre tank pumps on the A319ceo and some A320ceo, by jet pump transfer into the wings on the others, automatically with MODE SEL at AUTO.
  • The outer tanks (A319ceo, A320ceo, A320neo) keep their fuel for wing bending and flutter relief until the inner tanks are down to about 750 kg.
  • A leak can be hard to detect: one sign is fuel on board plus fuel used falling short of the fuel at engine start.

Sources FCOM DSC-28-10-20 TANKS / FCOM DSC-28-10-20 / FCOM DSC-28-10-30 / FCOM DSC-28-10-30 MAIN COMPONENTS / FCOM DSC-28-10-10 GENERAL / FCOM DSC-28-10-30 FUEL FEED SEQUENCE / FCOM DSC-28-20 / FCOM PRO-ABN-FUEL FUEL F. USED/FOB DISAGREE / FCTM PR-AEP-FUEL FUEL LEAK

The FUEL page of the A320ceo ECAM, as the platform draws it: a healthy aircraft in the cruise
The FUEL pageAs our ECAM Trainer draws it: an A320ceo, healthy, in the cruise.

Why does the A320 need a fuel system at all?

Start with the obvious jobs. The fuel has to be stored, delivered to the two engines and the APU, and, on the ground, put into the right tanks in the right quantities when the aircraft is refuelled.

Then the less obvious ones. Some of the fuel sent to each engine passes through the integrated drive generator (IDG) heat exchanger, where it absorbs heat, and returns to a tank. On the A319ceo, A320ceo and A320neo the system keeps fuel in the outer tanks for wing bending and flutter relief, which is why that fuel is used last. And on the A320neo, the A321neo and some A320ceo it controls the transfer of fuel from the centre tank into the wings.

Sources FCOM DSC-28-10-10 GENERAL / FCOM DSC-28-10-30 FUEL FEED SEQUENCE / FCOM DSC-28-10-60

What the fuel system does

What the fuel system doesOne box, the fuel system, above six jobs: the engines, the APU, refuelling, IDG cooling, wing bending relief on the A319ceo, A320ceo and A320neo, and centre to wing transfer on the A320neo, A321neo and some A320ceo. Fuel systemtanks, pumps, valvesEnginesboth of themAPURefuellingthe right tanksIDG coolingfuel absorbs heatWing reliefA319ceo, A320ceo, A320neoCentre transferA320neo, A321neo, some ceo
One system, six jobs: feed the engines and the APU, take fuel in at refuelling, cool the IDGs, keep fuel in the outer tanks for the wing, and on some types move the centre tank fuel into the wings.

What is the simplest way to picture it?

Picture the wing from the front. On the A319ceo, A320ceo and A320neo each wing holds an inner and an outer tank, with the centre tank between the wings, a vent surge tank outboard of each wing, and on some aircraft one or two additional centre tanks (ACT).

Now the one rule to remember: each engine is fed from its own side. Engine 1 takes its fuel from the left wing, engine 2 from the right (the centre tank comes in at step 3), and the two sides are joined by the cross-feed valve, which opens when the crew sets X FEED to ON.

Usable fuel without ACT is 23 724 l on the A320neo, 23 580 l on the A321neo, and 23 859 to 24 209 l on the A319ceo and A320ceo, depending on the version. Full, the fuel can still expand by 2 % (a 20 °C rise) without spilling.

Sources FCOM DSC-28-10-20 / FCOM DSC-28-10-30 MAIN COMPONENTS / FCOM DSC-28-10-30 / FCOM DSC-28-20 / FCOM DSC-28-10-20 TANKS

Step 1: five tanks, each side feeding its own engine

Step 1: five tanks, each side feeding its own engineFive tanks in a row: left outer, left inner, centre, right inner, right outer. Engine 1 above the left inner tank, fed from it; engine 2 above the right inner tank, fed from it. ENG 1ENG 2OUTER TANKleft wingINNER TANKleft wingCENTRE TANKbetween the wingsINNER TANKright wingOUTER TANKright wing
Step 1 of 4. The tanks of the A319ceo, A320ceo and A320neo, from the front: outer and inner tanks in each wing, the centre tank between them. Each engine takes its fuel from its own side. The A321neo has one tank in each wing instead of two.

How does the fuel get to the engines?

Add the pumps one at a time. In normal operation each engine is supplied by two pumps in the inner tank on its own side (the wing tank on the A321neo) or, on the centre pump design, by one centre tank pump.

Behind the pumps is a fall-back. Suction valves, closed by pump pressure in normal operation, let the engines be fed by gravity if the wing tank pumps fail.

Between the two sides is the cross-feed valve, driven by a double motor. Open, it lets both engines be fed from one side, or one engine from both. Each engine also has its low pressure (LP) fuel valve, closed by the engine master switch or the ENG FIRE PUSH pushbutton.

The APU is fed from the same system, with a special pump for an APU start when fuel feed pressure is low.

Sources FCOM DSC-28-10-30 MAIN COMPONENTS / FCOM DSC-28-10-30 / FCOM DSC-28-10-10 GENERAL / FCOM DSC-28-10-30 ENGINE FEED / FCOM DSC-28-10-50 APU FEED

Step 2: the pumps, the suction valves and the cross-feed

Step 2: the pumps, the suction valves and the cross-feedThe left inner tank feeds L TK PUMPS 1 and 2, which feed engine 1; the right inner tank feeds R TK PUMPS 1 and 2, which feed engine 2. Dashed links from each inner tank through its suction valves to its engine, and a dashed two-way cross-feed valve between the engines. The centre tank sits between the inner tanks. ENG 1X FEEDvalve, closedENG 2Suction valvesgravity feedL TK PUMPS1 and 2R TK PUMPS1 and 2Suction valvesgravity feedINNER TANKleft wingCENTRE TANKINNER TANKright wing
Step 2 of 4. Two pumps in each inner tank feed their own engine. Dashed: the suction valves, closed by pump pressure, which let an engine be fed by gravity if its pumps fail; and the cross-feed valve, which joins the two sides when it is open.
Live aircraft

Take the pumps away yourself

The live aircraft is an A320ceo built with centre tank pumps, in the cruise at FL 350 with the centre tank empty. The FUEL panel below works: every press changes the schematic above it.

The system's schematic as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
  1. Predict Engine 1 has two pumps. If you switch L TK PUMP 1 off, does engine 1 keep its fuel?

    Try it Switch L TK PUMP 1 off.

    Pump 2 goes on feeding engine 1. The pushbutton shows OFF in white, and its FAULT light stays out: it does not come on when OFF is selected.

    Sources FCOM DSC-28-10-30 / FCOM DSC-28-20 FUEL

  2. Predict Now switch L TK PUMP 2 off as well, with the cross-feed closed. What feeds engine 1?

    Try it Switch L TK PUMP 2 off.

    With no pump pressure, the suction valves let engine 1 draw fuel from its inner tank by gravity. It is a fall-back with limits: the gravity feeding procedure sets a ceiling and asks the crew to avoid negative g.

    Sources FCOM DSC-28-10-30 / FCOM PRO-ABN-FUEL / FCOM PRO-ABN-FUEL FUEL

  3. Try it Open the cross-feed: set X FEED to ON.

    The right pumps now feed both engines. When both pumps of a wing are lost with no leak and, as here, the centre tank empty, this is what the ECAM asks for above FL 150.

    Sources FCOM DSC-28-10-30 / FCOM PRO-ABN-FUEL FUEL

  4. Try it Switch both left pumps back on, and X FEED off.

    Each side feeds its own engine again.

    Sources FCOM DSC-28-10-30

How is the centre tank emptied, and what does MODE SEL do?

The centre tank is used before the wings, and the FCOM describes two ways of emptying it.

Centre tank pumps (the A319ceo and some A320ceo). Two pumps in the centre tank feed the engines directly, making six main pumps in all. The wing tank pumps stay on throughout the flight, but they are fitted with pressure relief sequence valves, so that when all the pumps run, the centre tank pumps deliver fuel first. The centre tank pumps have no suction valves: the centre tank cannot feed by gravity.

Jet pump transfer (the A320neo, the A321neo and other A320ceo). The centre tank has no feed pumps, and the engines are fed from the wings. When a centre tank transfer valve opens, fuel from the wing tank pumps flows through a jet pump, and its suction draws centre tank fuel into that wing's tank.

With MODE SEL at AUTO, the logic needs no help. The centre tank pumps run for 2 min at engine start and, before or after the start sequence, whenever the slats are retracted; each stops while its inner tank is full and restarts once about 500 kg has been used from it. The transfer valves open while the wing tank is not full and reopen after 500 kg has been used (250 kg on the A321neo). Either way, the centre fuel stops 5 min after the centre tank reaches low level.

At MAN, the centre tank pumps run, or the transfer valves open, and the crew switches them off when the centre tank is empty (the transfer valves also when the wings are full). On the centre pump design, nothing then stops the pumps at a full inner tank, so a wing can overflow on the ground if they are left on.

Sources FCOM DSC-28-10-30 FUEL FEED SEQUENCE / FCOM DSC-28-10-30 GENERAL / FCOM DSC-28-10-30 / FCOM DSC-28-20 FUEL / FCOM DSC-28-10-60 / FCOM DSC-28-20

Step 3: two ways to empty the centre tank

Step 3: two ways to empty the centre tankTwo designs side by side. Centre tank pumps, on the A319ceo and some A320ceo: centre tank to CTR TK PUMPS to the engines, with the inner tanks' pumps feeding second. Jet pump transfer, on the A320neo, A321neo and other A320ceo: centre tank through a jet pump into the wing tanks, whose pumps feed the engines, and whose flow drives the jet pump. Centre tank pumpsA319ceo, some A320ceoENGINESCTR TK PUMPSdeliver firstTK PUMPSon all flight, secondCENTRE TANKINNER TANKSJet pump transferA320neo, A321neo, other A320ceoENGINESJET PUMPdriven by pump flowTK PUMPSin each wingCENTRE TANKWING TANKSinner tanks on A320
Step 3 of 4. Left, the centre pump design: the centre tank pumps feed the engines first, and the wing pumps, on throughout the flight, take over when the centre pumps' pressure drops. Right, the jet pump design: wing pump flow drives a jet pump that draws centre fuel into the wing tank, and the wing pumps feed the engines.
Live aircraft

Run the centre tank

Now the centre tank holds 3 000 kg and both centre tank pumps are feeding, MODE SEL at AUTO. Try the tasks, then the failures.

The system's schematic as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
The E/WD as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
  1. Predict The centre pumps are feeding. If you switch CTR TK PUMP 1 off, what feeds engine 1?

    Try it Switch CTR TK PUMP 1 off.

    The left wing pumps were on all along. On this design a wing pump feeds only when the delivery pressure of the centre tank pumps drops below the threshold, and here it just has.

    Sources FCOM DSC-28-10-30 / FCOM DSC-28-20 FUEL

  2. Try it Switch CTR TK PUMP 1 back on.

    The centre pump delivers first again: the wing pumps stay on, and their sequence valves give way to it.

    Sources FCOM DSC-28-10-30

  3. Predict Switch both CTR TK PUMPs off, with 3 000 kg still in the centre tank. Will the FUEL page show it?

    Try it Switch both CTR TK PUMPs off.

    The centre fuel cannot reach the engines, not even by gravity, so the FOB is half-boxed in amber: not all of it is usable. The FCOM also gives a caution, FUEL CTR TK PUMPS OFF, when both pushbuttons are off with no failure.

    Sources FCOM DSC-28-10-30 / FCOM DSC-28-20 FUEL / FCOM PRO-ABN-FUEL FUEL CTR TK PUMPS OFF / FCOM PRO-ABN-FUEL FUEL

Failure Fail the automatic feed

Here both centre pumps stop with fuel still in the centre tank, the engines use wing fuel, and the caution comes at once; on the aircraft it needs more than 250 kg in the centre tank with a wing tank below 5 000 kg, or centre pumps that do not stop after slat extension or at centre tank low level.

Sources FCOM PRO-ABN-FUEL FUEL AUTO FEED FAULT / FCOM DSC-28-20

Work this failure in the ECAM Trainer

Try it Set MODE SEL to MAN, as the ECAM asks.

At MAN the centre tank pumps run and feed the engines. The crew switches them off when the centre tank is empty, and on aircraft with CFM engines at slat extension if it is not, against a possible wing tank overflow on the ground.

Sources FCOM DSC-28-10-30 FUEL FEED SEQUENCE / FCOM PRO-ABN-FUEL FUEL

Failure Fail centre pump 1

The pump runs but its delivery pressure drops: its FAULT light comes on, and the left wing pumps take over engine 1 while engine 2 goes on using centre fuel.

Sources FCOM DSC-28-10-30 / FCOM DSC-28-20 / FCOM PRO-ABN-FUEL FUEL CTR TK PUMP 1(2) LO PR

Work this failure in the ECAM Trainer

Try it Set X FEED to ON, as the ECAM asks when there is no leak, and switch CTR TK PUMP 1 off.

The remaining centre pump feeds both engines through the cross-feed. When the centre tank is empty, X FEED goes off again, to avoid a possible fuel imbalance.

Sources FCOM PRO-ABN-FUEL FUEL

In what order do the tanks empty, and where does the IDG fuel go?

The tanks empty in sequence: any ACT fuel into the centre tank, then the centre tank, then the inner tanks down to 750 kg each, and only then the outer tanks, draining into the inner tanks. The A321neo ends with its wing tanks.

The outer tank transfer is automatic and one-way. When an inner tank reaches its low level, about 750 kg, the transfer valves open; each of the two level sensors in an inner tank controls one valve in each wing, so both wings transfer together. The valves stay latched open until the next refuelling. The 750 kg assumes a level aircraft with no acceleration: in a steep descent, or when accelerating or decelerating, they may open with more fuel in the inner tanks.

The IDG fuel closes the loop. It leaves the engine's high-pressure fuel line, passes through the IDG heat exchanger and returns, through a fuel return valve the FADEC controls, to the outer tank (the wing tank on the A321neo). If the outer tank is full, it spills into the inner tank. On the centre pump design, this is why a centre tank feeding at MAN can overfill the wings.

Sources FCOM DSC-28-10-30 FUEL FEED SEQUENCE / FCOM DSC-28-10-60

Step 4: the order the tanks empty

Step 4: the order the tanks emptyFour steps in a row: 1, the ACT if fitted, into the centre tank; 2, the centre tank; 3, the inner tanks down to 750 kg each; 4, the outer tanks, draining into the inner tanks. Below the outer tanks, the IDG return from each engine, dashed, into the outer tank. 1. ACTif fitted, into centre2. CENTRE TANK3. INNER TANKSdown to 750 kg each4. OUTER TANKSdrain into the innerIDG returnfrom each engine
Step 4 of 4. The A319ceo, A320ceo and A320neo sequence: ACT, centre, inner tanks down to 750 kg, then the outer tanks drain into the inner tanks. The IDG fuel returns to the outer tank. The A321neo has no outer tanks: its sequence ends at the wing tanks, and its IDG fuel returns there.

What does the crew see, and touch?

On the overhead FUEL panel: L and R TK PUMPS 1 and 2; CTR TK PUMP 1 and 2 or CTR TK L and R XFR, depending on the design; MODE SEL; X FEED; and ACT, inoperative when no ACT is installed. A tank pump's pushbutton shows OFF in white when selected off, and an amber FAULT light with an ECAM caution when its delivery pressure drops.

On the FUEL page of the SD: each tank's quantity and, where its sensor is wet, its temperature. A wing pump is a green line when its pressure is normal, LO in amber when it is low, and an amber crossline when it is off; a centre tank pump's crossline is green when the logic has shut it off as required. The cross-feed valve is in line when open, across the line when closed, and amber when it disagrees with the pushbutton.

The FOB is half-boxed in amber when not all the fuel shown is usable, and two dashes across its last two digits mean the quantity indication is degraded.

Sources FCOM DSC-28-20 FUEL / FCOM DSC-28-20

Live aircraft

The panel and the FUEL page, together

The same aircraft as the crew sees it: the FUEL panel and the FUEL page. Press, and watch the page.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
  1. Try it Set X FEED to ON, and watch the valve on the FUEL page.

    On the panel, ON comes on in white and, once the valve is fully open, the green OPEN light. On the page, the valve turns in line, in green.

    Sources FCOM DSC-28-20 / FCOM DSC-28-20 FUEL

  2. Try it Switch R TK PUMP 2 off.

    OFF in white on the panel and no FAULT light, because the pump was selected off rather than failed. On the page, the pump is drawn as an amber crossline: its contactor is off.

    Sources FCOM DSC-28-20 FUEL

What happens when a wing's pumps fail?

One pump first: its FAULT light comes on with an ECAM caution, and the FUEL page shows LO in amber.

Both pumps of one wing is the case to know: FUEL L (R) TK PUMP 1 + 2 LO PR. On the jet pump design, and on the centre pump design once the centre tank is empty, the crew sets X FEED to ON if there is no leak and the aircraft is above FL 150, so that the other wing feeds both engines. Leak or not, ENG MODE SEL goes to IGN, because continuous relight "protects against flame-out, caused by possible fuel supply surging", and the failed pumps are switched off. Below FL 150 the cross-feed is closed again: that engine runs on gravity, and negative g is avoided.

On the centre pump design with fuel still in the centre tank, the procedure has no cross-feed step: MODE SEL goes to MAN, if the centre tank is not feeding, so that the centre tank pumps run, and the failed pumps are switched off.

Gravity feeding has a ceiling. After more than 30 min above FL 300 it is the current level. Otherwise, in one version, for some aircraft, it is FL 200. In the other it is FL 300 after less than 30 min above FL 300, the higher of FL 150 and 7 000 ft above the takeoff airport if FL 300 was never exceeded, and FL 100 with JET B.

The cross-feed valve can fail too: FUEL X FEED VALVE FAULT means its position disagrees with the selection. Failed closed, if an acceptable balance cannot be kept, the aircraft lands as soon as possible.

Sources FCOM DSC-28-20 FUEL / FCOM PRO-ABN-FUEL FUEL L (R) TK PUMP 1 + 2 LO PR / FCOM PRO-ABN-FUEL FUEL / FCOM PRO-ABN-FUEL / FCOM PRO-ABN-FUEL (CENTER TANK EMPTY) / FCOM PRO-ABN-FUEL (CENTER TANK NOT EMPTY) / FCOM PRO-ABN-FUEL FUEL X FEED VALVE FAULT

Live aircraft

Fail it yourself

The cruise again, centre tank empty. Press a failure, see what the aircraft does by itself, then do what the ECAM asks.

The system's schematic as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
The E/WD as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model

Failure Fail both left wing pumps

Both left pumps lose their pressure and show LO in amber. Engine 1 keeps running, on gravity feed from its inner tank.

Sources FCOM DSC-28-10-30 / FCOM DSC-28-20 FUEL / FCOM PRO-ABN-FUEL (CENTER TANK EMPTY)

Work this failure in the ECAM Trainer

Try it Above FL 150 with no leak: set X FEED to ON, then switch L TK PUMP 1 and 2 off, the FUEL panel steps the ECAM asks for.

The right pumps feed both engines through the cross-feed. The left tank's fuel is used by gravity later, when it is needed.

Sources FCOM PRO-ABN-FUEL FUEL / FCOM PRO-ABN-FUEL

Failure Jam the cross-feed valve

The valve is open with X FEED off, so the page draws it in line, in amber, and the two sides are joined. With the valve failed open, the crew keeps the balance by using the pumps selectively.

Sources FCOM DSC-28-20 FUEL / FCOM PRO-ABN-FUEL FUEL X FEED VALVE FAULT / FCOM PRO-ABN-FUEL FUEL

Work this failure in the ECAM Trainer

Why do a low level and an imbalance matter?

FUEL L (R) WING TK LO LVL triggers when a wing tank holds less than 750 kg. It comes from level sensors going dry and is independent of the quantity indications, so even when the quantities are in doubt, "Fuel low level alerts remain reliable as they are computed using independent sensors."

If the centre tank is not empty, MODE SEL goes to MAN. If there is no leak (and, in one version, for some aircraft, a fuel imbalance), the cross-feed is opened and the low side's pumps are switched off, so that the other wing feeds both engines.

Both wings low, FUEL L + R WING TK LO LVL, means LAND ASAP. All the tank pumps go on (with MODE SEL at MAN if the centre tank is not empty, and on the jet pump design the centre transfer valves on as well), and the cross-feed is opened if there is no leak, or closed if the engines are on gravity feed.

An imbalance on its own gets an advisory on the FUEL page in flight phases 2 and 6 when the wings differ by more than 1 500 kg. The FUEL IMBALANCE procedure lets the heavier side feed both engines through the cross-feed, with the centre tank fuel stopped, until the fuel is balanced. But it carries a caution: "A fuel imbalance may indicate a fuel leak." If a leak is suspected, it is not applied.

Sources FCOM PRO-ABN-FUEL FUEL L (R) WING TK LO LVL / FCOM DSC-28-10-80 FUEL LEVEL SENSING CONTROL UNIT (FLSCU) / FCOM PRO-ABN-FUEL / FCOM PRO-ABN-FUEL FUEL / FCOM PRO-ABN-FUEL FUEL L + R WING TK LO LVL / FCOM PRO-ABN-FUEL ABNORMAL AND EMERGENCY PROCEDURES / FCOM DSC-28-20 FUEL / FCOM DSC-28-20

Two ways of knowing how much fuel is left

Two ways of knowing how much fuel is leftTwo columns. Left: level sensors, dry below 750 kg, give the LO LVL alert, which remains reliable. Right: the FQI's capacitance probes in each tank give the quantities and the FOB, shown with dashes when degraded. Level sensorsdry below 750 kgFQI probescapacitance, in each tankLO LVL alertremains reliableQuantities, FOBdashes when degraded
The quantities on the FUEL page and the FOB come from the FQI's probes, and can be degraded. The low level alerts come from separate level sensors, and stay reliable.

How does the crew find a fuel leak?

The FCTM is blunt: significant fuel leaks, "although rare, are sometimes difficult to detect." The first defence is the routine fuel check, when overflying a waypoint or at least every 30 min: the fuel on board plus the fuel burnt should match the fuel on board at the gate, and the fuel on board should match the flight plan.

The ECAM sees the same sum. FUEL F. USED/FOB DISAGREE triggers when the initial FOB differs significantly from the current FOB plus the fuel used. In one version, for some aircraft, it branches: a sum higher than the initial FOB leads to the FUEL OVERREAD procedure, a lower one to FUEL LEAK. In the other it leads to FUEL LEAK.

Finding the source is the job of the QRH FUEL LEAK procedure, and the FCTM sums up its logic. A leak confirmed from an engine or pylon (excessive fuel flow, low N1, or seen from the cabin) means shutting that engine down. Otherwise each tank is isolated: cross-feed closed, centre fuel stopped, each wing feeding its own engine. A wing that drops faster points to that wing or its engine, and shutting that engine down tells which; both wings dropping evenly with the centre tank falling points to the centre tank or the APU feed line.

Sources FCTM PR-AEP-FUEL FUEL LEAK / FCOM PRO-ABN-FUEL FUEL F. USED/FOB DISAGREE / FCOM PRO-ABN-FUEL FUEL / FCOM PRO-ABN-ABN-QRH ABNORMAL AND EMERGENCY PROCEDURES / FCOM PRO-ABN-FUEL

Finding a fuel leak

Finding a fuel leakA leak suspected leads two ways. Confirmed from an engine or pylon: the engine is shut down. Not located: each tank is isolated; one wing dropping faster points to that wing or its engine; both wings and the centre dropping point to the centre tank or the APU feed line. Leak suspectedthe fuel does not add upEngine or pylonconfirmedNot locatedisolate each tankEngine shut downleak isolatedOne wing fasterthat wing or its engineWings and centrecentre tank or APU line
The FCTM's summary of the QRH FUEL LEAK logic: an engine or pylon leak, once confirmed, is isolated by shutting the engine down; otherwise the tanks are isolated and the way they drop points to the source.
Live aircraft

A leak you cannot see

The cruise once more. Press the failure: the leak is drawn on the schematic, but the alert only says what the crew would know.

The system's schematic as the live aircraft starts, drawn by the platform's systems model
The E/WD as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model

Failure Start a leak at engine 1

The alert names no tank and no engine, and its procedure sends the crew to FUEL LEAK. With the cross-feed closed, each wing feeds only its own engine, so this leak would show as the left wing's fuel decreasing abnormally fast.

Sources FCOM PRO-ABN-FUEL FUEL F. USED/FOB DISAGREE / FCOM PRO-ABN-FUEL FUEL / FCTM PR-AEP-FUEL FUEL LEAK

Work this failure in the ECAM Trainer

What differs between the A319, A320 and A321, ceo and neo?

The cross-feed valve, the LP valves, the suction valves and the APU feed pump work the same way on all of them. The tanks, the way the centre tank is emptied and some alerts do not.

  • A319ceo and some A320ceo: inner and outer tanks, six main pumps including two centre tank pumps that feed the engines directly, and no gravity feed from the centre tank.
  • A320neo and other A320ceo: inner and outer tanks, four main pumps, and centre tank fuel transferred into the inner tanks by jet pumps.
  • A321neo: one tank in each wing, so no outer tanks and no outer transfer; four main pumps; jet pump transfer that reopens after 250 kg rather than 500 kg; and the IDG fuel returned to the wing tank.
  • Imbalance limits: the A321neo has its own table, for its single wing tanks.
  • Centre tank alerts: FUEL AUTO FEED FAULT and FUEL CTR TK PUMP 1(2) LO PR are given in the versions for some aircraft, FUEL AUTO TRANSFER FAULT in those for others.
  • FUEL F. USED/FOB DISAGREE: the overread branch is in one version only, for some aircraft.

Sources FCOM DSC-28-10-30 / FCOM DSC-28-10-50 APU FEED / FCOM DSC-28-10-20 TANKS / FCOM DSC-28-10-20 / FCOM DSC-28-10-30 GENERAL / FCOM DSC-28-10-30 FUEL FEED SEQUENCE / FCOM DSC-28-10-60 / FCOM PRO-ABN-FUEL FUEL AUTO FEED FAULT / FCOM PRO-ABN-FUEL FUEL AUTO TRANSFER FAULT / FCOM PRO-ABN-FUEL FUEL CTR TK PUMP 1(2) LO PR / FCOM PRO-ABN-FUEL FUEL / FCOM LIM-FUEL MAXIMUM ALLOWED FUEL IMBALANCE

Go further

The studio's own lessons on this system, played step by step on the panel and the SD page, and the Interactive Flight Deck at the FUEL panel.

Open the flight deck at this panel

In the ECAM Trainer

Work these fuel system failures as a crew, line by line against the FCOM, in the ECAM Trainer. Red: a warning; amber: a caution.

Open the ECAM Trainer

Limitations

  • Minimum fuel quantity for takeoffNo wing tank low level ECAM alert may appear for takeoffFCOM LIM-FUEL · MINIMUM FUEL QUANTITY FOR TAKEOFF
    1 500 kg
  • Minimum fuel temperature, JET A1 / JP8 / N°3 JETSame in both fuel tablesFCOM LIM-FUEL · FUEL TEMPERATURE
    -43 °C
  • Minimum fuel temperature, JET AFCOM LIM-FUEL · FUEL TEMPERATURE
    -36 °C
  • JET A: monitor fuel temperature on the FUEL SD page when TAT reachesFCOM LIM-FUEL · FUEL TEMPERATURE
    -34 °C
  • Max fuel imbalance at takeoff, inner tanks (outer balanced), heavier inner tank fullA319ceo, A320ceo, A320neoLinear between table valuesFCOM LIM-FUEL · MAXIMUM ALLOWED FUEL IMBALANCE
    500 kg
  • Max fuel imbalance at takeoff, inner tanks, heavier inner tank 3 000 kgA319ceo, A320ceo, A320neoFCOM LIM-FUEL · MAXIMUM ALLOWED FUEL IMBALANCE
    1 050 kg
  • Max fuel imbalance at takeoff, inner tanks, heavier inner tank 1 450 kgA319ceo, A320ceo, A320neoFCOM LIM-FUEL · MAXIMUM ALLOWED FUEL IMBALANCE
    1 450 kg
  • Max fuel imbalance at takeoff, outer tanks (inner balanced)A319ceo, A320ceo, A320neoFCOM LIM-FUEL · MAXIMUM ALLOWED FUEL IMBALANCE
    370 kg
  • Max fuel imbalance in flight and at landing, inner tanks (outer balanced), heavier inner tank fullA319ceo, A320ceo, A320neoLinear between table valuesFCOM LIM-FUEL · MAXIMUM ALLOWED FUEL IMBALANCE
    1 500 kg
  • Max fuel imbalance in flight and at landing, inner tanks, heavier inner tank 4 300 kgA319ceo, A320ceo, A320neoFCOM LIM-FUEL · MAXIMUM ALLOWED FUEL IMBALANCE
    1 600 kg
  • In flight and at landing, no inner tank imbalance limitation belowA319ceo, A320ceo, A320neoFCOM LIM-FUEL · MAXIMUM ALLOWED FUEL IMBALANCE
    2 250 kg
  • Max fuel imbalance in flight and at landing, outer tanksA319ceo, A320ceo, A320neoOne full/one empty allowed under the footnote conditionsFCOM LIM-FUEL · MAXIMUM ALLOWED FUEL IMBALANCE
    690 kg
  • Outer tank imbalance footnote: max difference between inner tank quantitiesA319ceo, A320ceo, A320neoFCOM LIM-FUEL · MAXIMUM ALLOWED FUEL IMBALANCE
    3 000 kg

Every limitation, by system

Videos

Every video on this system

Key abbreviations

ACT
Additional Centre Tank
FLSCU
Fuel Level Sensing Control Unit
FQI
Fuel Quantity Indication
FOB
Fuel On Board
FU
Fuel Used
LP
Low Pressure
IDG
Integrated Drive Generator
FADEC
Full Authority Digital Engine Control System
APU
Auxiliary Power Unit
CTR
Centre
TK
Tank, Track
XFR
Transfer
LVL
Level
SD
System Display
ECAM
Electronic Centralised Aircraft Monitoring
FCTM
Flight Crew Techniques Manual
QRH
Quick Reference Handbook

The FCOM's full list

Train this system

A320 fuel system in the Knowledge Trainer

112 questions on this system, each explained from the FCOM with its source, and the trainer brings back what you got wrong until it sticks.

Train this system

Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The live aircraft is the platform's systems model, the same one the ECAM Trainer and the flight deck run. Aircraft differ by type, engine and options: your aircraft's FCOM and your operator's procedures always come first. How we write and check these pages.

Know this system

Learn it from the FCOM, one question at a time.

The Knowledge Trainer has 2,517 questions across all 18 systems, each explained from the FCOM. Start free today, or open everything with A320 Knowledge+.

For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.