A320 oxygen system
High-pressure oxygen feeding a mask at every cockpit seat, cabin masks that drop from their containers, fed by chemical generators, and a hood for fighting smoke. Built up one piece at a time, with the live OXYGEN panel and DOOR/OXY page to try.
- In short
- Why does the A320 carry three oxygen systems?
- What is the simplest way to picture the crew oxygen?
- What does the crew mask do, and how is it set?
- What does the crew see, and touch?
- How much crew oxygen is enough to fly?
- How do the passenger masks drop, and how long do they last?
- In a depressurisation, what is automatic and what is the crew's?
- What does the crew breathe in smoke, and what is the smoke hood for?
- What can go wrong with the oxygen, and how does the crew know?
- What differs between the A319, A320 and A321, ceo and neo?
Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy
In short
The A320 has three oxygen systems: a fixed one for the cockpit, fed from one or two high-pressure cylinders, by type; a fixed one for the cabin, fed by chemical generators; and portable equipment, in the cockpit and the cabin, for crew protection and first aid.
- Crew oxygen: one cylinder on the A319ceo and A320ceo, two on the A320neo and A321neo, with pressure regulators and supply solenoid valves that let the crew shut off the distribution.
- Masks: a full-face quick-donning mask at each seat, with N (diluted), 100 % and an EMERGENCY overpressure.
- Indications: the crew pressure on the DOOR/OXY page, green, then pulsing, then amber, at thresholds that differ by type.
- Passengers: the masks drop automatically above 14 000 ft cabin altitude (16 000 ft with HI ALT LANDING on, where fitted), or when the crew presses MASK MAN ON.
- Smoke hood: protects one flight crew member fighting a fire, in smoke or fumes, for 15 min in the FCOM's descriptions.
Sources FCOM DSC-35-10 DESCRIPTION / FCOM DSC-35-20-10 GENERAL / FCOM DSC-35-30-10 GENERAL / FCOM DSC-35-20-20 OVERHEAD PANEL / FCOM DSC-35-20-20 PRESSURE REGULATOR / FCOM DSC-35-20-20 ECAM DOOR/OXY PAGE / FCOM DSC-35-30-10 OPERATION / FCOM DSC-35-30-20 OVERHEAD PANEL / FCOM DSC-35-40-10 FLIGHT CREWS PORTABLE OXYGEN SYSTEM

Why does the A320 carry three oxygen systems?
Because three groups need oxygen in different ways. The cockpit fixed system gives the cockpit occupants breathing oxygen in a depressurisation, or when smoke or noxious gases appear. The cabin fixed system gives the passengers and the cabin crew oxygen in a depressurisation. Portable oxygen, in both the cockpit and the cabin, protects the crew during on board emergencies and serves for first aid.
The sources differ too: the crew breathes from high-pressure cylinders through a regulator, the cabin from generators that make it on demand. Those are the FCOM's stated purposes; the abnormal procedures also use the masks in other cases, such as volcanic ash.
Sources FCOM DSC-35-10 DESCRIPTION / FCOM DSC-35-20-10 GENERAL / FCOM DSC-35-30-10 GENERAL / FCOM PRO-ABN-MISC
Three systems, three sets of users
What is the simplest way to picture the crew oxygen?
A teaching image first: a scuba bottle with a tap, feeding a mask at every seat. On the A319ceo and A320ceo the FCOM gives one high-pressure cylinder, in the left-hand lower fuselage. A pressure regulator, connected directly to it, brings the pressure down to a value the masks can use, and two overpressure safety systems vent the oxygen overboard if the pressure becomes too high.
The tap is a supply solenoid valve, controlled by the CREW SUPPLY pushbutton on the overhead OXYGEN panel. Pressed in, the valve is open and low pressure oxygen reaches the masks, the normal position in flight; released, the valve closes and a white OFF light comes on. At the end of the line are three, or on aircraft so fitted four, full-face quick-donning masks, one at each seat.
Sources FCOM DSC-35-20-10 GENERAL / FCOM DSC-35-20-20 OVERHEAD PANEL
Step 1: one bottle to every mask
What does the crew mask do, and how is it set?
The mask is built to go on fast. Squeezing the red grips pulls it out of its box and inflates the harness; once the mask is on, releasing the grip deflates the harness, which holds the mask in place. As soon as the box's left flap door opens, the mask is supplied with oxygen.
A regulator on the mask gives three ways to breathe. At N (normal) it mixes cabin air and oxygen, with more oxygen as the cabin altitude rises, until it gives pure oxygen. At 100 % it gives pure oxygen at all cabin altitudes; the selector is locked at 100 % when the mask is pulled out of its box.
The EMERGENCY pressure selector adds overpressure, which clears condensation or fogging and "prevents smoke, smell or ashes from entering the mask." Pressed, it gives a few seconds of it; turned, permanent overpressure. It starts by itself above 30 000 ft cabin altitude, and the FCOM says it is available only with 100 % selected.
On the stowage box, a yellow blinker flashes while oxygen flows, and an OXY ON flag shows a closed box whose mask is still supplied. Pressing the RESET/TEST slide after use cuts off the oxygen and the mask microphone; left in EMERGENCY, the pressure selector can deplete the crew cylinder.
Sources FCOM DSC-35-20-10 OPERATION / FCOM DSC-35-20-10 MASK SETTING / FCOM DSC-35-20-20 STOWAGE BOX / FCOM DSC-35-20-20 PRESSURE REGULATOR / FCOM DSC-35-20-10 MASK STOWAGE
The mask regulator's three settings
What does the crew see, and touch?
On the overhead and the ECAM, the crew oxygen has one pushbutton and one display: CREW SUPPLY on the OXYGEN panel, and the top corner of the ECAM DOOR/OXY page, under the title CKPT OXY, with the bottle pressure in PSI (one figure per bottle on the A320neo and A321neo).
The pressure reads like a fuel gauge with marks. On the A319ceo and A320ceo it is green from 800 PSI; below 800 PSI it pulses and the DOOR/OXY page comes up by itself; below 400 PSI it is amber. On the ground an amber half frame appears below 1 500 PSI, and the crew must then check the quantity against the minimum in the limitations. Some A320ceo, and the A320neo and A321neo, use other figures (see the diagram).
The CKPT OXY title, normally white, turns amber for three reasons: the pressure below the amber figure, a low oxygen pressure detected, or CREW SUPPLY off. For the pulsing pressure, the ECAM advisory recommends checking that any mask not in use is correctly stowed.
Sources FCOM DSC-35-20-20 OVERHEAD PANEL / FCOM DSC-35-20-20 ECAM DOOR/OXY PAGE / FCOM PRO-ABN-ABN-ADV
When the crew pressure changes colour
Switch the crew oxygen off and on
At the gate, an A320ceo with one crew bottle. The OXYGEN panel is below, beside the recorder and calls panels, with the DOOR/OXY page next to it.


-
Predict The bottle pressure is green. When you release CREW SUPPLY, what happens to the CKPT OXY title on the DOOR/OXY page?
Try it Release CREW SUPPLY.
The white OFF light comes on and CKPT OXY turns amber, while the pressure stays green: with the pushbutton off, the supply solenoid valve is closed, the valve that lets the crew shut off the distribution system.
Sources FCOM DSC-35-20-10 GENERAL / FCOM DSC-35-20-20 OVERHEAD PANEL / FCOM DSC-35-20-20 ECAM DOOR/OXY PAGE
-
Predict You press CREW SUPPLY back in. What does the CKPT OXY title show now?
Try it Press CREW SUPPLY back in.
The OFF light goes out and CKPT OXY is white again: the valve is open, and on is the pushbutton's normal position in flight.
Sources FCOM DSC-35-20-20 OVERHEAD PANEL / FCOM DSC-35-20-20 ECAM DOOR/OXY PAGE
How much crew oxygen is enough to fly?
Not one figure. The FCTM reads the half frame as advice that the bottle should be refilled, sends the crew to the minimum flight crew oxygen pressure in the limitations, and says prolonged dispatch in that state is not recommended.
The minimum comes from tables that read two things: how many people use the cockpit oxygen (two crew with up to two observers on the A319ceo and A320ceo; each bottle with its pilot, alone or with that side's observer, on the A320neo and A321neo), and a reference temperature, on the ground the mean of the OAT and the cockpit temperature. More people, or a warmer reference, give a higher minimum.
It covers the preflight checks, oxygen used while one pilot is alone in the cockpit, the unusable quantity, normal leakage, and the more demanding of two cases: a depressurisation on N, an emergency descent then a cruise at FL 100, or smoke, 100 % oxygen for everyone for 15 min at 8 000 ft cabin altitude.
The mask is tested from its stowage box, with the crew supply on: the test checks the blinker, the regulator supply and the system's sealing. The FCOM warns that the ground crew may hear a loud noise in the headset.
Sources FCOM DSC-35-20-20 ECAM DOOR/OXY PAGE / FCTM PR-NP-SOP-40 OXYGEN / FCOM LIM-OXY MINIMUM FLIGHT CREW OXYGEN PRESSURE / FCOM DSC-35-20-20 STOWAGE BOX / FCOM DSC-35-20-30 HOW TO TEST THE MASK
What the minimum bottle pressure covers
How do the passenger masks drop, and how long do they last?
The cabin needs no bottles. Chemical generators produce the oxygen, each feeding 2, 3 or 4 masks, in containers above the passenger seats, in the lavatories, at each cabin crew station and, where fitted, in each galley. On some aircraft gaseous generators replace the chemical ones in the lavatories.
Each container has an electrical latch that opens automatically when the cabin pressure altitude exceeds 14 000 ft, or 16 000 ft with the HI ALT LANDING pushbutton-switch on, where fitted, each with a tolerance of + 250 ft and - 750 ft. The crew can override it: the guarded MASK MAN ON pushbutton opens the mask doors. Once the control for the mask doors is activated, the white PASSENGER SYS ON light comes on and stays on until maintenance presses TMR RESET.
A dropped mask gives nothing until it is pulled towards the seat, which starts the generator. The reaction is hot, so "the smell of burning, smokes and cabin temperature increase may be associated with the normal operation of the oxygen generators." The mask then gives pure oxygen for about 13 min, 15 min or up to 22 min, depending on the installation.
On the A320ceo, A320neo and A321neo the crew sees the drop, automatic or manual, as the OXY PAX ON memo: green when both CPCs detect an excessive cabin altitude, amber when one or both do not. For an electrical failure, a manual release tool opens the mask doors by hand.
Sources FCOM DSC-35-30-10 GENERAL / FCOM DSC-35-30-10 OPERATION / FCOM DSC-35-30-20 OVERHEAD PANEL / FCOM DSC-35-30-20 OVERHEAD MAINTENANCE PANEL / FCOM DSC-35-30-20
How the cabin masks come down
Release the passenger masks
After a depressurisation: the CAB PRESS page beside the OXYGEN panel shows the cabin altitude just above 14 000 ft. The guarded MASK MAN ON pushbutton is at AUTO.


-
Predict You lift the guard and press MASK MAN ON. Which light on the OXYGEN panel shows that the mask doors' control is activated?
Try it Lift the guard and press MASK MAN ON.
The white SYS ON light comes on. Here the live aircraft had not released the masks by itself at 14 100 ft; the FCOM gives the automatic release at 14 000 ft with a tolerance of + 250 ft and - 750 ft. With the cabin above 14 000 ft the procedures give this press: "This action confirms that the passenger oxygen masks are released." The FCTM allows it earlier when the cabin will obviously pass 14 000 ft.
Sources FCOM DSC-35-30-10 OPERATION / FCOM DSC-35-30-20 OVERHEAD PANEL / FCOM PRO-ABN-MISC / FCTM PR-AEP-MISC EMER DESCENT
In a depressurisation, what is automatic and what is the crew's?
The ECAM and the memory items carry the procedure; this is only the logic around the oxygen. Some of it is automatic: in cruise CAB PR EXCESS CAB ALT triggers above 9 550 ft cabin altitude, the passenger masks drop above 14 000 ft (16 000 ft with HI ALT LANDING on, where fitted), and the crew mask's overpressure starts above 30 000 ft cabin altitude.
Putting the crew masks on is the crew's first action, not the aircraft's: the first line of EMER DESCENT, a procedure the FCOM lists among the memory items, and in CAB PR EXCESS CAB ALT a line under the condition of being above FL 100. With masks on, the procedures ask the crew to make sure they can communicate, and to avoid continuous use of the interphone, to limit the interference from the masks' breathing noise.
In the descent the crew saves oxygen with the diluter at N: left at 100 %, the procedures warn, it may not last the whole descent profile. In the procedures MASK MAN ON is conditional too, on the cabin being above 14 000 ft, and confirms the release; the FCTM allows it earlier when the cabin will obviously exceed 14 000 ft. The FCTM counts a delayed descent among the risks, for the limited oxygen it leaves the passengers, and has the crew press the PRESS TO RESET slide once the masks are off.
Sources FCOM PRO-ABN-CAB_PR CAB PR EXCESS CAB ALT / FCOM DSC-35-30-10 OPERATION / FCOM DSC-35-20-20 PRESSURE REGULATOR / FCOM PRO-ABN-ABN-MEM / FCOM PRO-ABN-CAB_PR CAB PR / FCOM PRO-ABN-MISC / FCTM PIR RISKS RELATED TO SYSTEM OPERATIONS/FAILURES / FCTM PR-AEP-MISC EMER DESCENT
Automatic, or the crew's
What does the crew breathe in smoke, and what is the smoke hood for?
Smoke changes the mask setting. Once smoke is confirmed, the SMOKE / FUMES / AVNCS SMOKE procedure has the mask and goggles, if required, used at 100 % and EMERG, and has the crew turn the emergency knob to remove condensation or smoke from the mask. The procedure gives no further reason; the mask units say what each setting does: at N the regulator mixes cabin air with the oxygen, at 100 % it gives pure oxygen, and the overpressure "prevents smoke, smell or ashes from entering the mask."
The smoke hood, at the right aft side of the cockpit, protects the eyes and lungs of one flight crew member fighting a fire, in smoke or noxious gas, or in a depressurisation. The untyped description gives it an oxygen cylinder and a CO2 absorption system, 15 min of use, and an indicator that must not be red. The A320ceo units list other models (see the differences).
In a lithium battery fire in the cockpit the two are shared out: if there are flames, the PF uses the oxygen mask and the PM the smoke hood, and the FCTM puts both before the PM discharges the extinguisher.
Volcanic ash calls for the crew masks at 100 % and EMER, and the passenger masks as required. The REMOVAL OF SMOKE / FUMES procedure, in its case without fuel vapours, adds for the passenger masks: "Do not deploy oxygen masks, if fire is suspected in the cabin."
Sources FCOM PRO-ABN-SMOKE / FCOM DSC-35-20-10 OPERATION / FCOM DSC-35-20-20 PRESSURE REGULATOR / FCOM DSC-35-40-10 FLIGHT CREWS PORTABLE OXYGEN SYSTEM / FCTM PR-AEP-SMOKE LITHIUM BATTERY FIRE IN THE COCKPIT / FCOM PRO-ABN-MISC
What can go wrong with the oxygen, and how does the crew know?
The crew oxygen reports on the DOOR/OXY page. A low bottle pressure shows as the pulsing, then amber figure; a low pressure in the low-pressure circuit, 50 PSI, as REGUL LO PR in amber. The CKPT OXY title turns amber with the pressure below the amber figure, with a low oxygen pressure detected, or with CREW SUPPLY off.
In one version of the FCOM's electrical emergency configuration table, for some aircraft, the crew oxygen and the passenger mask release are normal with the emergency generator running. On batteries only, the passenger mask release ("auto + man" in the table) is inoperative, and the crew oxygen stays normal with the crew supply solenoid valve inoperative.
Sources FCOM DSC-35-20-20 ECAM DOOR/OXY PAGE / FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC LOUDSPEAKER 1 NORM NORM NORM
Three ways to an amber CKPT OXY
A low pressure in the crew oxygen
At the gate, the crew bottle pressure green. Press the failure and watch the DOOR/OXY page. The platform's ECAM library has no reviewed scenario for an oxygen alert, so this failure has no E/WD.


Failure Low pressure: REGUL LO PR
REGUL LO PR comes up in amber, the FCOM's indication for a low pressure, 50 PSI, in the low-pressure circuit, while the bottle pressure stays green. Here the CKPT OXY title turns amber too; the FCOM lists a detected low oxygen pressure among the reasons for the amber title, without saying whether that is the REGUL LO PR condition. Here nothing changes on the OXYGEN panel, and the units cited here give no crew action for it.
Sources FCOM DSC-35-20-20 ECAM DOOR/OXY PAGE
What differs between the A319, A320 and A321, ceo and neo?
The cabin oxygen description and the crew mask units carry no type applicability. The cockpit supply does: on the A320neo and A321neo it is split in two: one sub-system for the Captain and the third occupant, one for the First Officer and the fourth, with two cylinders, two regulators, two supply solenoid valves and four overpressure safety systems.
- DOOR/OXY page: on the A320neo and A321neo, CAPT on the left and F/O on the right, each pulsing below 500 PSI and amber below 200 PSI, the ground half frame below 800 PSI, and REGUL 1, 2 or 1+2 LO PR.
- Minimum pressure: the ceo tables are by crew and observers, the neo tables by bottle; some A320ceo have their own tables.
- Mask test: the A320neo and A321neo version uses the RMP, the untyped one the ACP.
- Smoke hood: the A320ceo is also listed with a solid state oxygen hood, and some A320ceo with a PBE using chemical air regeneration, for at least 15 min.
- Memos: HI ALT SET is listed for the A320ceo; the OXY PAX ON unit for the A320ceo, A320neo and A321neo.
The live aircraft on this page is an A320ceo, with one bottle.
Sources FCOM DSC-35-20-10 GENERAL / FCOM DSC-35-20-10 OPERATION / FCOM DSC-35-20-20 PRESSURE REGULATOR / FCOM DSC-35-30-10 GENERAL / FCOM DSC-35-30-10 OPERATION / FCOM DSC-35-20-20 ECAM DOOR/OXY PAGE / FCOM LIM-OXY MINIMUM FLIGHT CREW OXYGEN PRESSURE / FCOM DSC-35-20-30 HOW TO TEST THE MASK / FCOM DSC-35-40-10 FLIGHT CREWS PORTABLE OXYGEN SYSTEM / FCOM DSC-35-30-20 MEMO DISPLAY / FCOM DSC-35-30-20
Step 2: two bottles, two sides
Go further
The studio's own lessons on this system, played step by step on the panel and the SD page, and the Interactive Flight Deck at the OXYGEN panel.
Memory items
The memory items that belong to this system. Each one is on our memory items page in full, with its conditions and references.
Key abbreviations
- PBE
- Portable Breathing Equipment
- CPC
- Cabin Pressure Controller
- ECAM
- Electronic Centralised Aircraft Monitoring
- SD
- System Display
- RMP
- Radio Management Panel
- ACP
- Audio Control Panel
- FL
- Flight Level
- PF
- Pilot Flying
- PM
- Pilot Monitoring
- OAT
- Outside Air Temperature
- LP
- Low Pressure
- FCTM
- Flight Crew Techniques Manual
- TMR
- Timer
- E/WD
- Engine/Warning Display

A320 oxygen system in the Knowledge Trainer
79 questions on this system, each explained from the FCOM with its source, and the trainer brings back what you got wrong until it sticks.
Train this systemWritten in our own words from the FCOM and the FCTM; each part names the units it rests on. The live aircraft is the platform's systems model, the same one the ECAM Trainer and the flight deck run. Aircraft differ by type, engine and options: your aircraft's FCOM and your operator's procedures always come first. How we write and check these pages.
Learn it from the FCOM, one question at a time.
The Knowledge Trainer has 2,517 questions across all 18 systems, each explained from the FCOM. Start free today, or open everything with A320 Knowledge+.
For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.
Related
- A320 air conditioning and pressurisationTwo packs cool the air, trim air warms each zone, and one outflow valve holds the cabin altitude, built up one piece at a time, with the…
- A320 fire protectionTwo loops that must agree while both work, a pushbutton that isolates an engine, bottles the crew fires, and one APU bottle that fires…
- A320 communicationsRadios tuned on one panel, heard and keyed on another, an audio unit between them, a cabin system for the cabin and service interphones and…
- A320 procedures and techniquesWhy the A320 has flows, checklists, memory items, ECAM procedures and a QRH, and how two pilots share them. The logic and the philosophy,…
- All 18 A320 systemsWhat each system is, and where to study it
