An amber caution with one line, and the FCOM's own worked example of the ECAM. Here is what is too hot, what the blue electric pump's switch really takes away, why no other system can stand in for blue, and what STATUS offers if the overheat goes.
Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy
What HYD B RSVR OVHT means
HYD B RSVR OVHT is an amber caution: the hydraulic fluid returning to the blue reservoir is too hot, 93 °C or more. The ECAM's one line switches the blue electric pump off, which depressurises the whole blue system: B SYS LO PR follows, with a secondary failure in the flight controls.
No other normal source stands in for blue: its electric pump is its only normal pump, its RAT driven pump is for an emergency, and the PTU links green and yellow only. If the overheat goes out, STATUS has the crew set the pump back to AUTO.
Sources FCOM PRO-ABN-HYD HYD B RSVR OVHT / FCOM DSC-29-20 ECAM HYD PAGE / FCOM PRO-ABN-HYD HYD / FCOM DSC-31-25-20 / FCOM DSC-29-10-20 BLUE SYSTEM PUMPS / FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM PRO-ABN-HYD

At a glance
- Level
- Amber caution, level 2: single chime and a steady amber MASTER CAUT light
- Sets it off
- Blue fluid at 93 °C or more; the caution resets at 88 °C or less, the same in every version
- Lights
- FAULT in the BLUE ELEC PUMP pushbutton, and OVHT in amber by the blue reservoir on the HYD page
- The line
- BLUE ELEC PUMP, OFF; then B SYS LO PR, with *F/CTL as a secondary failure
- Landing
- STATUS: the pump back to AUTO if the overheat goes out; if blue is not recovered, the landing distance procedure
Sources FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-30 ATTENTION GETTERS / FCOM DSC-31-25-20 / FCOM PRO-ABN-HYD HYD B RSVR OVHT / FCOM DSC-29-20 OVERHEAD PANEL / FCOM DSC-29-20 ECAM HYD PAGE / FCOM PRO-ABN-HYD HYD / FCOM PRO-ABN-HYD
What exactly is overheating?
Not the pump: the fluid. The HYD page's OVHT under a reservoir appears in amber, with a caution, when the temperature of the returning fluid at the reservoir's inlet is above normal. For blue, the caution triggers at 93 °C or more and resets at 88 °C or less.
The blue electric pump has an overheat of its own, which the HYD page shows as OVHT by the pump, and which gives a different caution, HYD B ELEC PUMP LO PR OR OVHT. The reservoir overheat is about the fluid coming back to the reservoir.
The same overheat lights the FAULT light in the BLUE ELEC PUMP pushbutton: that light covers a low reservoir level, a reservoir overheat, low reservoir air pressure, low pump pressure and a pump overheat.
Sources FCOM DSC-29-20 ECAM HYD PAGE / FCOM PRO-ABN-HYD HYD B RSVR OVHT / FCOM PRO-ABN-HYD HYD B ELEC PUMP LO PR OR OVHT / FCOM DSC-29-20 OVERHEAD PANEL
What does the crew see and hear?
The FCOM uses this very caution as its example of the ECAM sequence. A single chime sounds, both MASTER CAUTION lights come on and stay on, a FAULT light comes on on the overhead HYD panel, the E/WD shows HYD B RSVR OVHT with BLUE ELEC PUMP OFF under it, and the SD calls up the HYD page with OVHT in amber by the blue system.
A level 2 caution means the crew should be aware of it but needs no immediate action; time and situation permitting, it should be considered without delay, to prevent any further degradation of the affected system.
Sources FCOM DSC-31-25-20 / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION
The moment the caution comes on
A healthy aircraft in the cruise, all three systems at 3 000 psi. Press the button to overheat the blue reservoir, then look at the E/WD, the HYD page and the HYD panel.



The alert Overheat the blue reservoir
The E/WD shows HYD B RSVR OVHT in amber with BLUE ELEC PUMP OFF. The HYD page shows OVHT in amber by the blue reservoir, and the BLUE ELEC PUMP pushbutton shows FAULT.
Blue still has its pressure: the pump is still running, and the FCOM's own example shows blue at 3 000 psi at this point. The caution warns about the fluid, it has switched nothing off. Working the line is what the ECAM Trainer does with you, free.
Sources FCOM DSC-31-25-20 / FCOM DSC-29-20 ECAM HYD PAGE / FCOM DSC-29-20 OVERHEAD PANEL / FCOM PRO-ABN-HYD HYD B RSVR OVHT
Why switch the pump off, and what goes with it?
The FCOM does not state a reason for the line in words; it states its effect. Switching the BLUE ELEC PUMP off de-energises the pump, and in the worked example it depressurises the blue hydraulic circuit: a single chime sounds again, the pushbutton shows FAULT and OFF, B SYS LO PR appears, and the HYD page shows an amber zero for blue with the amber OVHT.
That takes the whole of blue, because blue has one pump in normal operation, an electric one; its other pump, driven by the RAT, is for an emergency. And the PTU cannot help: it joins green and yellow, not blue. Hydraulic fluid cannot be transferred from one system to another in any case.
The FAULT light does not go out at OFF, as it does for its other causes: during an overheat it stays on as long as the overheat lasts.
Sources FCOM DSC-29-20 OVERHEAD PANEL / FCOM DSC-31-25-20 / FCOM DSC-29-10-20 BLUE SYSTEM PUMPS / FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM DSC-29-10-10 GENERAL
Switch the blue pump off
The blue reservoir is overheating, and the blue pump is still running. Predict first, then switch the BLUE ELEC PUMP off on the panel and watch the schematic and the HYD page.



-
Predict What happens to the blue system when its electric pump goes off?
Try it Switch the BLUE ELEC PUMP off.
Blue's pressure falls to zero and its name turns amber: the electric pump was its only source. The PTU does not move, because it links green and yellow only, and both still have their engine pumps.
On the schematic, the blue users lose their pressure: spoiler 3, the slats, and blue's share of the rudder, the elevators and the ailerons. The FAULT light stays on with OFF while the overheat lasts.
Sources FCOM DSC-29-10-20 BLUE SYSTEM PUMPS / FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM DSC-29-20 ECAM HYD PAGE / FCOM DSC-29-10-30 DISTRIBUTION / FCOM DSC-29-20 OVERHEAD PANEL
How does the ECAM walk the crew through it?
Once the pump is off, the E/WD's second part changes to B SYS LO PR, and the right side of the memo area shows a secondary failure in the flight controls. The procedure lists FUEL CONSUMPT INCRSD and FMS PRED UNRELIABLE among its associated procedures, and *F/CTL as its secondary failure.
The crew then clears the alert. With the first CLR the hydraulic messages leave the E/WD and the SD calls up the F/CTL page, with the blue actuators in amber. The next brings the STATUS page, and the STS pushbutton lights; the last puts a status reminder at the bottom of the E/WD and the SD back to the page for the flight phase.
FUEL CONSUMPT INCRSD appears when the failure affects the aircraft's nominal aerodynamic characteristics. FMS PRED UNRELIABLE means the FMS fuel predictions are disregarded and the applicable fuel penalty factor is used instead.
Sources FCOM DSC-31-25-20 / FCOM PRO-ABN-HYD HYD / FCOM PRO-ABN-HYD
What does the aircraft lose with blue?
The STATUS page's INOP SYS gives the answer for this failure: BLUE HYD, SPLR 3, CAT 3 DUAL, B ELEC PUMP and, where fitted, STEEP APPR. Its information lines include SLATS SLOW and CAT 3 SINGLE ONLY.
The surfaces blue shares keep the other systems' pressure: the rudder is on all three systems, each elevator and the ailerons on two. The emergency generator, which blue drives through a hydraulic motor when the RAT is out, is not on this STATUS list.
Sources FCOM PRO-ABN-HYD / FCOM DSC-29-10-30 DISTRIBUTION / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS
What goes with the blue pump
What is lost afterwards?

STATUS is the SD's operational summary of the aircraft's state. Under APPR PROC, HYD LO PR, it gives the way back: if the blue overheat goes out, the BLUE ELEC PUMP goes back to AUTO. If the system is not recovered, the landing distance procedure applies.
The information lines in green carry FUEL CONSUMPT INCRSD, FMS PRED UNRELIABLE, SLATS SLOW and CAT 3 SINGLE ONLY; INOP SYS lists what goes with blue.
The worked example in the FCOM's ECAM description shows a different STATUS for this failure, with LDG DIST x 1.1 in place of the landing distance procedure; the one drawn here is the procedure's own.
Sources FCOM PRO-ABN-HYD / FCOM DSC-31-20 STATUS PAGE / FCOM DSC-31-25-20
A319ceo, A320ceo, A320neo, A321neo: what differs?
| A319ceo, A320ceo | A320neo, A321neo | |
|---|---|---|
| Alert threshold | 93 °C or more, resetting at 88 °C or less | 93 °C or more, resetting at 88 °C or less |
| Procedure and STATUS | The same in every version | The same in every version |
Blue's threshold is the same on every aircraft. Green's and yellow's are not: in one version of their triggering conditions, for some aircraft, they trigger at 98 °C and reset at 93 °C.
Sources FCOM PRO-ABN-HYD HYD B RSVR OVHT / FCOM PRO-ABN-HYD HYD / FCOM PRO-ABN-HYD / FCOM PRO-ABN-HYD HYD G RSVR OVHT / FCOM PRO-ABN-HYD HYD Y RSVR OVHT

Work HYD B RSVR OVHT as a crew
Read and do each line against the FCOM, with the E/WD, the SD page and the overhead following your hands, the PF and PM calls, and a debrief that says what you missed.
Work this failure in the ECAM TrainerGo further
Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The E/WD, the STATUS and the live aircraft are the platform's own ECAM and systems model, the same the ECAM Trainer and the flight deck run. This page explains the procedure; it is not the procedure. Aircraft differ by type, engine and options: your aircraft's FCOM, your QRH and your operator's procedures always come first. How we write and check these pages.
Every ECAM procedure, line by line, against the FCOM.
The ECAM Trainer works 108 scenarios with the E/WD, the SD page and the overhead following your hands. Start free today, or open everything with A320 Knowledge+.
For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.
Related
- HYD B+Y SYS LO PRA red warning: blue and yellow are lost and green is left alone, still in normal law.
- HYD B ELEC PUMP LO PRAn amber caution that costs a whole system.
- HYD B RSVR LO LVLAn amber caution: the blue system is losing its fluid.
- HYD G+B SYS LO PRA red warning: green and blue are lost and yellow is left alone.
- A320 hydraulic systemThe system guide, with the live aircraft
- Every ECAM procedureThe alerts the ECAM Trainer works, grouped by system