- Home
- ECAM procedures
- FUEL X FEED VALVE FAULT
FUEL X FEED VALVE FAULT
An amber caution with nothing to press. Here is what the cross-feed valve disagreeing with its pushbutton means, what a valve stuck open does to the two wings' fuel, and how the crew keeps the balance with the pumps, with the live aircraft at the moment the caution comes on.
- What it means
- What sets the caution off?
- What does the crew see and hear?
- How do the pumps keep the balance with the valve stuck open?
- What does crew awareness leave to the crew?
- What does a failed valve take away?
- What is lost afterwards?
- Type differences
- Related failures
- Work it in the ECAM Trainer
- Go further
Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy
What FUEL X FEED VALVE FAULT means
FUEL X FEED VALVE FAULT is an amber caution: the cross-feed valve is not where the X FEED pushbutton has put it. The valve joins the two sides of the fuel system, so that both engines can be fed from one side or one engine from both.
The procedure is crew awareness, with nothing to press. If the valve has failed open, the crew keeps the fuel balanced by using the pumps selectively. If it has failed closed and an acceptable balance cannot be kept, the aircraft lands as soon as possible. STATUS lists FUEL X FEED as inoperative.
Sources FCOM PRO-ABN-FUEL FUEL X FEED VALVE FAULT / FCOM DSC-28-10-30 / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM PRO-ABN-FUEL FUEL

At a glance
- Level
- Amber caution, level 2: single chime, MASTER CAUT and the FUEL page on the SD
- Sets it off
- The cross-feed valve's position disagrees with the position the X FEED pushbutton selects
- Failed open
- With X FEED off: the green OPEN light once the valve is fully open, and the valve drawn in line, in amber, on the FUEL page
- Procedure
- Crew awareness. Failed open, keep the fuel balanced with selective use of the pumps; failed closed with no acceptable balance, land as soon as possible
- STATUS
- FUEL X FEED inoperative, the same in every version
Sources FCOM PRO-ABN-FUEL FUEL X FEED VALVE FAULT / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-20 SYSTEM PAGES / FCOM DSC-28-20 / FCOM DSC-28-20 FUEL / FCOM PRO-ABN-FUEL FUEL
What sets the caution off?
Each engine is normally fed from its own side: engine 1 from the left wing, engine 2 from the right, or on some aircraft from a centre tank pump. Between the two sides sits one cross-feed valve, controlled by a double motor.
The crew moves it with the X FEED pushbutton. ON opens the valve and lights ON in white; the green OPEN light comes on once the valve is fully open. OFF closes the valve, and the pushbutton does not light.
The caution compares the two: it triggers when the valve's position disagrees with the selected position. That covers a valve open with X FEED off and a valve closed with X FEED on. The FUEL page draws each case in amber: in line for open with the pushbutton off, across the line for closed with the pushbutton on, and amber too while the valve is in transit.
Sources FCOM DSC-28-10-30 MAIN COMPONENTS / FCOM DSC-28-10-30 / FCOM DSC-28-20 / FCOM PRO-ABN-FUEL FUEL X FEED VALVE FAULT / FCOM DSC-28-20 FUEL
The pushbutton against the valve
What does the crew see and hear?
A level 2 caution: a single chime, MASTER CAUT steady amber and the caution in amber on the E/WD, and the SD calls up the FUEL page, the relevant system page. The procedure reads crew awareness: there is nothing to press.
With the valve stuck open and X FEED off, the panel shows no ON light, and the green OPEN light once the valve is fully open, and the FUEL page draws the valve in line, in amber. The green FUEL X FEED memo does not appear: it needs the pushbutton ON.
Sources FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-20 SYSTEM PAGES / FCOM PRO-ABN-FUEL FUEL / FCOM DSC-28-20 / FCOM DSC-28-20 FUEL
The moment the caution comes on
The cruise at FL 350, centre tank empty, each wing feeding its own engine. Press the button to jam the cross-feed valve open, then look at the E/WD, the FUEL page, the FUEL panel and the schematic.




The alert Jam the cross-feed valve open
As our ECAM draws it, the E/WD shows the caution in amber and nothing under it. X FEED is still off, yet its OPEN light is on, and the FUEL page draws the valve in line, in amber: open, with the pushbutton off.
On the schematic the two sides are now joined, and both engines draw on all four wing pumps. The FCOM gives what an open valve allows: both engines fed from one side, or one engine from both. One limit of this drawing: it flips the valve rather than jamming it, so X FEED ON here would close it, where a jammed valve would not move. Working the alert is what the ECAM Trainer does with you.
Sources FCOM PRO-ABN-FUEL FUEL / FCOM DSC-28-20 / FCOM DSC-28-20 FUEL / FCOM DSC-28-10-30 / FCOM PRO-ABN-FUEL FUEL X FEED VALVE FAULT
How do the pumps keep the balance with the valve stuck open?
With the valve open, neither wing is tied to its own engine any more. The FCOM's answer for a valve failed open is one sentence: maintain the fuel balance with selective use of the pumps.
Correcting an imbalance on purpose is a QRH procedure of its own, FUEL IMBALANCE. This page names it but does not walk it: its steps are the QRH's.
Sources FCOM PRO-ABN-FUEL FUEL / FCOM DSC-28-10-30 / FCOM PRO-ABN-ABN-QRH ABNORMAL AND EMERGENCY PROCEDURES / FCOM PRO-ABN-FUEL
Switch the lighter wing's pumps off
The cross-feed valve is stuck open with X FEED off, and the left wing holds a little less than the right. Predict first, then press, and watch which pumps feed each engine on the schematic. Leave X FEED off: the FCOM's guidance for a valve failed open uses the pumps, with no line for the pushbutton, and this drawing does not keep the valve open if X FEED is pressed.



-
Predict With the valve stuck open, you switch both left wing pumps off. What feeds engine 1 now?
Try it Switch L TK PUMP 1 and L TK PUMP 2 off.
The right wing now feeds both engines through the open valve, and engine 1 does not fall back on gravity. Both pushbuttons show OFF in white, with no FAULT light: they were selected off, not failed.
That is one way to use the pumps selectively, with the cross-feed open. The FCOM's guidance for this caution names no particular pumps.
Sources FCOM DSC-28-10-30 / FCOM DSC-28-20 FUEL / FCOM PRO-ABN-FUEL FUEL
-
Try it Switch both left pumps back on.
With every pump on and the valve still open, both wings feed both engines again, and the balance is the crew's to watch on the FUEL page. In flight phases 2 and 6 it gives an advisory once the two wings differ by more than 1 500 kg.
Sources FCOM DSC-28-10-30 / FCOM PRO-ABN-FUEL FUEL / FCOM DSC-28-20 FUEL / FCOM DSC-28-20
What does crew awareness leave to the crew?
The procedure is crew awareness, and the FCOM gives no reason for that. A level 2 caution is a failure the crew should be aware of without immediate action, yet one to consider without delay, time and situation permitting, so that the affected system does not degrade further.
In place of actions, the FCOM gives guidance for each case. Failed open, the sides are joined and the crew keeps the balance with the pumps. Failed closed, each wing still feeds its own engine, as in normal operation; if an acceptable balance cannot be kept, the aircraft lands as soon as possible.
What counts as acceptable is in the limitations. In flight they allow a larger asymmetry as the tanks empty, and the FCOM adds that in exceptional conditions, that is a fuel system failure, the values may be exceeded without significant effect on the handling: the aircraft remains fully controllable.
Sources FCOM PRO-ABN-FUEL FUEL / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-28-10-30 MAIN COMPONENTS / FCOM DSC-28-10-30 / FCOM LIM-FUEL MAXIMUM ALLOWED FUEL IMBALANCE
What does a failed valve take away?
Several fuel procedures use the cross-feed, which lets one side feed both engines. FUEL L TK PUMP 1+2 LO PR sets X FEED to ON above FL 150 with no leak. FUEL L WING TK LO LVL sets it to ON with no leak (one version adds a fuel imbalance), FUEL L+R WING TK LO LVL with no leak, and the QRH's FUEL IMBALANCE procedure uses it too.
For a valve failed closed, the guidance of this caution is the one to keep in mind: if an acceptable balance cannot be kept, land as soon as possible.
For a valve failed open, keep the fuel leak procedure in mind. FUEL LEAK is one of the QRH procedures, and the FCTM gives it the aim of isolating the leak, while an open cross-feed valve joins the two sides of the fuel system.
Sources FCOM DSC-28-10-30 / FCOM PRO-ABN-FUEL FUEL / FCOM PRO-ABN-FUEL ABNORMAL AND EMERGENCY PROCEDURES / FCOM PRO-ABN-FUEL / FCOM PRO-ABN-ABN-QRH ABNORMAL AND EMERGENCY PROCEDURES / FCTM PR-AEP-FUEL FUEL LEAK
The procedures that lean on the cross-feed
What is lost afterwards?

STATUS is the aircraft's operational summary. For this caution it holds one line, FUEL X FEED, under INOP SYS, in amber like every inoperative system, and nothing in the left column.
The FCOM prints one STATUS for this caution, with no type split, and the STATUS above shows it.
Sources FCOM PRO-ABN-FUEL FUEL / FCOM DSC-31-20 STATUS PAGE
A319ceo, A320ceo, A320neo, A321neo: what differs?
| A319ceo, A320ceo | A320neo, A321neo | |
|---|---|---|
| The caution, its procedure and STATUS | The same in every version | The same in every version |
| The cross-feed valve | One valve, double motor, the same on all four types | One valve, double motor, the same on all four types |
| The main fuel pumps | Not given by type: some aircraft have six, with one centre tank pump for each engine; others have four, all in the wing tanks | Not given by type: the same two designs, each for its own aircraft |
| Imbalance limits in flight and at landing, inner or wing tanks | Outer tanks balanced: 1 500 kg with the heavier tank full, rising to 2 250 kg at 2 250 kg; no limit below 2 250 kg | A320neo as the ceo; A321neo 1 320 kg full, rising to 2 350 kg at 2 350 kg; no limit below 2 350 kg |
Sources FCOM PRO-ABN-FUEL FUEL X FEED VALVE FAULT / FCOM PRO-ABN-FUEL FUEL / FCOM DSC-28-10-30 / FCOM DSC-28-10-30 GENERAL / FCOM DSC-28-10-30 MAIN COMPONENTS / FCOM LIM-FUEL MAXIMUM ALLOWED FUEL IMBALANCE

Work FUEL X FEED VALVE FAULT as a crew
Read and do each line against the FCOM, with the E/WD, the SD page and the overhead following your hands, the PF and PM calls, and a debrief that says what you missed.
Work this failure in the ECAM TrainerGo further
Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The E/WD, the STATUS and the live aircraft are the platform's own ECAM and systems model, the same the ECAM Trainer and the flight deck run. This page explains the procedure; it is not the procedure. Aircraft differ by type, engine and options: your aircraft's FCOM, your QRH and your operator's procedures always come first. How we write and check these pages.
Every ECAM procedure, line by line, against the FCOM.
The ECAM Trainer works 108 scenarios with the E/WD, the SD page and the overhead following your hands. Start free today, or open everything with A320 Knowledge+.
For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.
Related
- FUEL AUTO FEED FAULTAn amber caution with a short procedure.
- FUEL CTR TK PUMP 1 LO PRAn amber caution with a short procedure and a line that waits.
- FUEL F. USED/FOB DISAGREEAn amber caution with one line, and behind it the fuel check the FCTM asks the crew to make.
- FUEL L+R WING TK LO LVLAn amber caution that opens with LAND ASAP.
- A320 fuel systemThe system guide, with the live aircraft
- Every ECAM procedureThe alerts the ECAM Trainer works, grouped by system