- Home
- ECAM procedures
- ELEC STATIC INV FAULT
ELEC STATIC INV FAULT
An amber caution about a unit that does nothing in normal flight. The static inverter is the batteries' way into the AC side, for when only the batteries are supplying: the main generators lost and the emergency generator not supplying, or not yet coupled. Here is what it feeds, why the ELEC page does not change, and what the aircraft would be without it, with the live aircraft at the moment the caution comes on.
- What it means
- What is the static inverter for?
- What does the crew see and hear?
- Why does nothing change on the ELEC page?
- When would the crew miss it?
- And with the static inverter failed?
- Why does the ECAM ask for nothing?
- What is lost afterwards?
- Type differences
- Related failures
- Work it in the ECAM Trainer
- Go further
Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy
What ELEC STATIC INV FAULT means
ELEC STATIC INV FAULT is an amber caution: the static inverter has failed. The inverter transforms DC from battery 1 into 1 KVA of AC for part of the AC essential bus, and it comes on only when the batteries alone are supplying the aircraft.
In normal flight it supplies nothing, so nothing on the ELEC page changes and the FCOM prints no STATUS. What goes is a reserve: the way the batteries feed the AC ESS BUS when AC BUS 1 and 2 are not powered and the emergency generator is not supplying.
Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE / FCOM DSC-24-20 OVERHEAD PANEL

At a glance
- Level
- Amber caution, level 2: single chime, MASTER CAUT and the ELEC page on the SD
- Sets it off
- The static inverter has failed
- Its job
- Turning battery 1's DC into 1 KVA of 115 V 400 Hz AC for part of the AC ESS BUS, when only the batteries are supplying (below 50 kt, with both BAT pushbuttons on as well)
- In normal flight
- Nothing changes: AC BUS 1 supplies the AC ESS BUS, and the inverter supplies nothing
- Inhibited
- In flight phases 3, 4, 5, 7 and 8: from takeoff power to 1 500 ft, and from 800 ft to 80 kt after touchdown
- STATUS
- None printed in the FCOM for this caution
Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-20 SYSTEM PAGES / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE / FCOM PRO-ABN-ABN-00 INTRODUCTION / FCOM DSC-31-15 FLIGHT PHASES / FCOM DSC-31-20 STATUS PAGE
What is the static inverter for?
Besides external power, the FCOM gives the A320 three ways to make AC: the engine and APU generators in normal configuration, the emergency generator when normal AC is not available, and, when all AC power is not available, the batteries' DC inverted into AC. The static inverter is that third way.
It transforms DC from battery 1 into one KVA of single-phase 115 V 400 Hz AC, which goes to part of the AC essential bus. Above 50 kt it comes on by itself whenever only the batteries are supplying, whatever the BAT 1 and BAT 2 pushbuttons show. Below 50 kt it also needs both pushbuttons on.
In that configuration battery 1 supplies the AC STAT INV BUS and, above 50 kt, the AC ESS BUS, while battery 2 supplies the DC ESS BUS. The FCOM's distribution table shows the same for the emergency configuration in the 8 s or so before the emergency generator is available.
Sources FCOM DSC-24-10-10 GENERAL / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE
Batteries only: the inverter at work
What does the crew see and hear?
A level 2 caution: a single chime, MASTER CAUT steady amber, the caution in amber on the E/WD, and the ELEC page called up on the SD. In the FCOM's terms the crew should be aware of the failure, but no immediate action is needed.
The FCOM's flight phase graphic marks the caution as inhibited in phases 3, 4, 5, 7 and 8, from the first engine at takeoff power to 1 500 ft and from 800 ft to 80 kt after touchdown. The FWC inhibits some warnings and cautions in certain flight phases to avoid alerting the crew unnecessarily at times of high workload, such as takeoff and landing.
Sources FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-20 SYSTEM PAGES / FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM PRO-ABN-ABN-00 INTRODUCTION / FCOM DSC-31-15 FLIGHT PHASES
The moment the caution comes on
The cruise, both engine generators on line. Before you press, decide which bus you expect to lose with the static inverter. Then fail it and compare the ELEC page and the schematic with what they showed before.



The alert Fail the static inverter
None. This E/WD shows ELEC STATIC INV FAULT in amber with no line under it, the colour of a caution, and the AC ESS BUS stays on AC BUS 1.
The ELEC page and the schematic look as they did before: in normal flight the inverter supplies nothing. Seeing the caution through as a crew is what the ECAM Trainer does with you.
Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE
Why does nothing change on the ELEC page?
The FCOM gives no reason in words, but its units show the inverter idle in normal flight: AC BUS 1 supplies the AC ESS BUS, the batteries are disconnected most of the time, and the distribution table shows no supply on the AC STAT INV BUS. The live aircraft's ELEC page and schematic do not change.
The ELEC page shows the static inverter's voltage and frequency during the static inverter test, and when the crew presses ELEC on the ECAM control panel while the ESS buses are supplied by the batteries. The voltage turns amber below 110 V or above 120 V, the frequency below 390 Hz or above 410 Hz.
The EMER GEN TEST pushbutton, pressed and held while only the batteries supply the aircraft, has the static inverter power the AC ESS BUS.
Sources FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE / FCOM DSC-24-20 ECAM ELEC PAGE / FCOM DSC-24-20 OVERHEAD PANEL (CONT'D)
Normal flight: before and after look the same
When would the crew miss it?
When the main AC and the emergency generator are both gone. If AC BUS 1 and AC BUS 2 are lost above 100 kt, the RAT extends and the blue system drives the emergency generator. If the RAT stalls, or on the ground below 100 kt, the emergency generator has nothing to drive it, and the emergency network transfers by itself to the batteries and the static inverter, shedding the AC SHED ESS and DC SHED ESS buses.
The FCTM puts a speed on it in the emergency electrical configuration: below 125 kt the RAT stalls and the network goes to the batteries; below 100 kt the DC BAT BUS is connected, and below 50 kt the AC ESS BUS is shed. The FCOM gives these last two steps on the ground. The batteries also carry the emergency network for the 8 s or so the emergency generator takes to couple.
Sources FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCTM PR-AEP-ELEC TECHNICAL BACKGROUND
Leave the batteries alone
The cruise, the APU not running, the static inverter healthy, and the emergency generator failed, so it cannot take over. Predict first, then switch both generators off on the ELEC panel and watch the essential buses.


-
Predict With no generator and no emergency generator left, what supplies the AC ESS BUS?
Try it Switch GEN 1 and GEN 2 off.
On the schematic the static inverter comes on by itself. Battery 1 feeds the AC STAT INV BUS and the AC ESS BUS through it, battery 2 feeds the DC ESS BUS, and the shed buses are shed. DC BUS 1, DC BUS 2 and the DC BAT BUS have no supply.
This is the configuration ELEC ESS BUSES ON BAT announces: the DC ESS and AC ESS busbars supplied by the batteries, the AC ESS BUS through the static inverter.
Sources FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE / FCOM DSC-24-20 OVERHEAD PANEL / FCOM PRO-ABN-ELEC ELEC ESS BUSES ON BAT / FCOM PRO-ABN-ELEC ELEC
And with the static inverter failed?
The FCOM describes the batteries-only configuration with a working inverter, and gives no description of it with the inverter failed. On batteries alone, the inverter is the FCOM's way of turning their DC into AC; battery 2's supply to the DC ESS BUS does not go through it.
Sources FCOM DSC-24-10-10 GENERAL / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL
The same, without the inverter
The same cruise and the same failed emergency generator, but this time the static inverter has failed too. Predict first, then switch both generators off.


-
Predict The static inverter has failed. What supplies the AC ESS BUS once both generators are off?
Try it Switch GEN 1 and GEN 2 off.
The schematic shows the AC ESS BUS and the AC STAT INV BUS without a supply, and the DC ESS BUS still on battery 2.
The FCOM shows what the AC ESS BUS is worth in another case: with only the batteries powering the emergency network on the ground below 50 kt, the AC ESS BUS is shed, which leads to the loss of all display units.
Sources FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS
Why does the ECAM ask for nothing?
The E/WD shows no action line under the title. The FCOM gives no reason. What it does show is that nothing in use is lost: in normal flight the inverter supplies nothing.
That fits the FCOM's level 2 caution: a failure the crew should be aware of, without immediate action. Time and situation permitting, cautions should still be considered without delay, to prevent any further degradation of the affected system.
Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION
What is lost afterwards?
The FCOM prints no STATUS for this caution, so there is no STATUS page to draw. STATUS is the aircraft's operational summary, and it appears by itself when the crew clears the last alert only if it is not empty: this caution alone brings none up.
Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-31-20 STATUS PAGE
A319ceo, A320ceo, A320neo, A321neo: what differs?
| A319ceo, A320ceo | A320neo, A321neo | |
|---|---|---|
| The caution and its trigger | The same in every version | The same in every version |
| The static inverter and when it comes on | The same on all four types | The same on all four types |
Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-24-10-20 AC GENERATORS

Work ELEC STATIC INV FAULT as a crew
Read and do each line against the FCOM, with the E/WD, the SD page and the overhead following your hands, the PF and PM calls, and a debrief that says what you missed.
Work this failure in the ECAM TrainerGo further
Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The E/WD, the STATUS and the live aircraft are the platform's own ECAM and systems model, the same the ECAM Trainer and the flight deck run. This page explains the procedure; it is not the procedure. Aircraft differ by type, engine and options: your aircraft's FCOM, your QRH and your operator's procedures always come first. How we write and check these pages.
Every ECAM procedure, line by line, against the FCOM.
The ECAM Trainer works 108 scenarios with the E/WD, the SD page and the overhead following your hands. Start free today, or open everything with A320 Knowledge+.
For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.
Related
- ELEC AC ESS BUS FAULTTwo blue lines and one pushbutton.
- ELEC AC ESS BUS SHEDAn amber caution about part of a bus.
- ELEC AC BUS 1 FAULTOne bus lost, and two more cautions follow it.
- ELEC AC BUS 2 FAULTOne amber caution, and no essential bus caution with it: AC BUS 2 does not normally supply the AC ESS BUS.
- A320 electrical systemThe system guide, with the live aircraft
- Every ECAM procedureThe alerts the ECAM Trainer works, grouped by system