Amber caution · ECAM procedure · free to read

ELEC STATIC INV FAULT

An amber caution about a unit that does nothing in normal flight. The static inverter is the batteries' way into the AC side, for when only the batteries are supplying: the main generators lost and the emergency generator not supplying, or not yet coupled. Here is what it feeds, why the ELEC page does not change, and what the aircraft would be without it, with the live aircraft at the moment the caution comes on.

Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy

The answer first

What ELEC STATIC INV FAULT means

ELEC STATIC INV FAULT is an amber caution: the static inverter has failed. The inverter transforms DC from battery 1 into 1 KVA of AC for part of the AC essential bus, and it comes on only when the batteries alone are supplying the aircraft.

In normal flight it supplies nothing, so nothing on the ELEC page changes and the FCOM prints no STATUS. What goes is a reserve: the way the batteries feed the AC ESS BUS when AC BUS 1 and 2 are not powered and the emergency generator is not supplying.

Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE / FCOM DSC-24-20 OVERHEAD PANEL

The E/WD at the moment ELEC STATIC INV FAULT triggers, drawn by the platform's ECAM engine: the amber caution title and the lines it shows
The E/WD at the alertAs our ECAM draws it, the moment it triggers: cruise at FL350.

At a glance

Level
Amber caution, level 2: single chime, MASTER CAUT and the ELEC page on the SD
Sets it off
The static inverter has failed
Its job
Turning battery 1's DC into 1 KVA of 115 V 400 Hz AC for part of the AC ESS BUS, when only the batteries are supplying (below 50 kt, with both BAT pushbuttons on as well)
In normal flight
Nothing changes: AC BUS 1 supplies the AC ESS BUS, and the inverter supplies nothing
Inhibited
In flight phases 3, 4, 5, 7 and 8: from takeoff power to 1 500 ft, and from 800 ft to 80 kt after touchdown
STATUS
None printed in the FCOM for this caution

Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-20 SYSTEM PAGES / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE / FCOM PRO-ABN-ABN-00 INTRODUCTION / FCOM DSC-31-15 FLIGHT PHASES / FCOM DSC-31-20 STATUS PAGE

What is the static inverter for?

Besides external power, the FCOM gives the A320 three ways to make AC: the engine and APU generators in normal configuration, the emergency generator when normal AC is not available, and, when all AC power is not available, the batteries' DC inverted into AC. The static inverter is that third way.

It transforms DC from battery 1 into one KVA of single-phase 115 V 400 Hz AC, which goes to part of the AC essential bus. Above 50 kt it comes on by itself whenever only the batteries are supplying, whatever the BAT 1 and BAT 2 pushbuttons show. Below 50 kt it also needs both pushbuttons on.

In that configuration battery 1 supplies the AC STAT INV BUS and, above 50 kt, the AC ESS BUS, while battery 2 supplies the DC ESS BUS. The FCOM's distribution table shows the same for the emergency configuration in the 8 s or so before the emergency generator is available.

Sources FCOM DSC-24-10-10 GENERAL / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE

Batteries only: the inverter at work

Batteries only: the inverter at workBottom row: battery 1, then a box for the lost sources, AC BUS 1, AC BUS 2 and the emergency generator, then battery 2. Battery 1 feeds the static inverter, which feeds the AC STAT INV BUS and part of the AC ESS BUS above 50 kt. Battery 2 feeds the DC ESS BUS. AC STAT INV BUSAC ESS BUSpart of it, above 50 ktDC ESS BUSSTATIC INVERTER1 KVA, 115 V 400 HzBAT 1NO AC SOURCEAC BUS 1, 2, EMER GENBAT 2
Neither AC BUS 1 nor AC BUS 2 is powered and the emergency generator is not supplying. Battery 1 feeds the AC STAT INV BUS and, above 50 kt, part of the AC ESS BUS through the static inverter; battery 2 feeds the DC ESS BUS.

What does the crew see and hear?

A level 2 caution: a single chime, MASTER CAUT steady amber, the caution in amber on the E/WD, and the ELEC page called up on the SD. In the FCOM's terms the crew should be aware of the failure, but no immediate action is needed.

The FCOM's flight phase graphic marks the caution as inhibited in phases 3, 4, 5, 7 and 8, from the first engine at takeoff power to 1 500 ft and from 800 ft to 80 kt after touchdown. The FWC inhibits some warnings and cautions in certain flight phases to avoid alerting the crew unnecessarily at times of high workload, such as takeoff and landing.

Sources FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-20 SYSTEM PAGES / FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM PRO-ABN-ABN-00 INTRODUCTION / FCOM DSC-31-15 FLIGHT PHASES

Live aircraft

The moment the caution comes on

The cruise, both engine generators on line. Before you press, decide which bus you expect to lose with the static inverter. Then fail it and compare the ELEC page and the schematic with what they showed before.

The E/WD as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
The system's schematic as the live aircraft starts, drawn by the platform's systems model

The alert Fail the static inverter

None. This E/WD shows ELEC STATIC INV FAULT in amber with no line under it, the colour of a caution, and the AC ESS BUS stays on AC BUS 1.

The ELEC page and the schematic look as they did before: in normal flight the inverter supplies nothing. Seeing the caution through as a crew is what the ECAM Trainer does with you.

Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE

Work this failure in the ECAM Trainer

Why does nothing change on the ELEC page?

The FCOM gives no reason in words, but its units show the inverter idle in normal flight: AC BUS 1 supplies the AC ESS BUS, the batteries are disconnected most of the time, and the distribution table shows no supply on the AC STAT INV BUS. The live aircraft's ELEC page and schematic do not change.

The ELEC page shows the static inverter's voltage and frequency during the static inverter test, and when the crew presses ELEC on the ECAM control panel while the ESS buses are supplied by the batteries. The voltage turns amber below 110 V or above 120 V, the frequency below 390 Hz or above 410 Hz.

The EMER GEN TEST pushbutton, pressed and held while only the batteries supply the aircraft, has the static inverter power the AC ESS BUS.

Sources FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE / FCOM DSC-24-20 ECAM ELEC PAGE / FCOM DSC-24-20 OVERHEAD PANEL (CONT'D)

Normal flight: before and after look the same

Normal flight: before and after look the sameAC BUS 1 feeds the AC ESS BUS. Below, battery 1 and the static inverter, now failed, with a dashed link to the AC ESS BUS that was not in use. Battery 2 sits on its hot bus, not supplying. AC BUS 1GEN 1AC ESS BUSon AC BUS 1BAT 1on its hot busSTATIC INVERTERfailed, was idleBAT 2on its hot bus
AC BUS 1 feeds the AC ESS BUS before the failure and after it. The static inverter sat idle on battery 1; failed, it is still not in the path.

When would the crew miss it?

When the main AC and the emergency generator are both gone. If AC BUS 1 and AC BUS 2 are lost above 100 kt, the RAT extends and the blue system drives the emergency generator. If the RAT stalls, or on the ground below 100 kt, the emergency generator has nothing to drive it, and the emergency network transfers by itself to the batteries and the static inverter, shedding the AC SHED ESS and DC SHED ESS buses.

The FCTM puts a speed on it in the emergency electrical configuration: below 125 kt the RAT stalls and the network goes to the batteries; below 100 kt the DC BAT BUS is connected, and below 50 kt the AC ESS BUS is shed. The FCOM gives these last two steps on the ground. The batteries also carry the emergency network for the 8 s or so the emergency generator takes to couple.

Sources FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCTM PR-AEP-ELEC TECHNICAL BACKGROUND

Live aircraft

Leave the batteries alone

The cruise, the APU not running, the static inverter healthy, and the emergency generator failed, so it cannot take over. Predict first, then switch both generators off on the ELEC panel and watch the essential buses.

The system's schematic as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
  1. Predict With no generator and no emergency generator left, what supplies the AC ESS BUS?

    Try it Switch GEN 1 and GEN 2 off.

    On the schematic the static inverter comes on by itself. Battery 1 feeds the AC STAT INV BUS and the AC ESS BUS through it, battery 2 feeds the DC ESS BUS, and the shed buses are shed. DC BUS 1, DC BUS 2 and the DC BAT BUS have no supply.

    This is the configuration ELEC ESS BUSES ON BAT announces: the DC ESS and AC ESS busbars supplied by the batteries, the AC ESS BUS through the static inverter.

    Sources FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE / FCOM DSC-24-20 OVERHEAD PANEL / FCOM PRO-ABN-ELEC ELEC ESS BUSES ON BAT / FCOM PRO-ABN-ELEC ELEC

And with the static inverter failed?

The FCOM describes the batteries-only configuration with a working inverter, and gives no description of it with the inverter failed. On batteries alone, the inverter is the FCOM's way of turning their DC into AC; battery 2's supply to the DC ESS BUS does not go through it.

Sources FCOM DSC-24-10-10 GENERAL / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL

Live aircraft

The same, without the inverter

The same cruise and the same failed emergency generator, but this time the static inverter has failed too. Predict first, then switch both generators off.

The system's schematic as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
  1. Predict The static inverter has failed. What supplies the AC ESS BUS once both generators are off?

    Try it Switch GEN 1 and GEN 2 off.

    The schematic shows the AC ESS BUS and the AC STAT INV BUS without a supply, and the DC ESS BUS still on battery 2.

    The FCOM shows what the AC ESS BUS is worth in another case: with only the batteries powering the emergency network on the ground below 50 kt, the AC ESS BUS is shed, which leads to the loss of all display units.

    Sources FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS

Why does the ECAM ask for nothing?

The E/WD shows no action line under the title. The FCOM gives no reason. What it does show is that nothing in use is lost: in normal flight the inverter supplies nothing.

That fits the FCOM's level 2 caution: a failure the crew should be aware of, without immediate action. Time and situation permitting, cautions should still be considered without delay, to prevent any further degradation of the affected system.

Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-10-30-40 DISTRIBUTION TABLE / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION

What is lost afterwards?

The FCOM prints no STATUS for this caution, so there is no STATUS page to draw. STATUS is the aircraft's operational summary, and it appears by itself when the crew clears the last alert only if it is not empty: this caution alone brings none up.

Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-31-20 STATUS PAGE

A319ceo, A320ceo, A320neo, A321neo: what differs?

A319ceo, A320ceoA320neo, A321neo
The caution and its triggerThe same in every versionThe same in every version
The static inverter and when it comes onThe same on all four typesThe same on all four types

Sources FCOM PRO-ABN-ELEC ELEC STATIC INV FAULT / FCOM DSC-24-10-20 AC GENERATORS

In the ECAM Trainer · A320 Knowledge+

Work ELEC STATIC INV FAULT as a crew

Read and do each line against the FCOM, with the E/WD, the SD page and the overhead following your hands, the PF and PM calls, and a debrief that says what you missed.

Work this failure in the ECAM Trainer

Go further

Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The E/WD, the STATUS and the live aircraft are the platform's own ECAM and systems model, the same the ECAM Trainer and the flight deck run. This page explains the procedure; it is not the procedure. Aircraft differ by type, engine and options: your aircraft's FCOM, your QRH and your operator's procedures always come first. How we write and check these pages.

Work it as a crew

Every ECAM procedure, line by line, against the FCOM.

The ECAM Trainer works 108 scenarios with the E/WD, the SD page and the overhead following your hands. Start free today, or open everything with A320 Knowledge+.

For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.