Red warning · ECAM procedure · free to read

ELEC ESS BUSES ON BAT

A red warning: the two essential buses are on the batteries, the emergency generator not supplying them. Here is what battery 1, battery 2 and the static inverter keep, what the one action of the procedure does, and what is left afterwards, with the live aircraft at the moment the warning comes on.

Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy

The answer first

What ELEC ESS BUSES ON BAT means

ELEC ESS BUSES ON BAT is a red warning: the DC ESS and AC ESS busbars are supplied by the batteries. With neither main AC bus supplied and the emergency generator not supplying, battery 2 supplies the DC ESS BUS and battery 1 the AC ESS BUS through the static inverter, while the shed essential buses go.

Its procedure is red LAND ASAP and one action: EMER ELEC PWR to MAN ON, which extends the RAT by hand so that the emergency generator takes the essential buses off the batteries. ELEC EMER CONFIG and its procedure remain.

Sources FCOM PRO-ABN-ELEC ELEC ESS BUSES ON BAT / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL / FCOM PRO-ABN-ELEC ELEC / FCOM DSC-24-20 OVERHEAD PANEL (CONT'D) / FCOM PRO-ABN-ELEC ELEC EMER CONFIG

The E/WD at the moment ELEC ESS BUSES ON BAT triggers, drawn by the platform's ECAM engine: the red warning title and the lines it shows
The E/WD at the alertAs our ECAM draws it, the moment it triggers: cruise at FL350.

At a glance

Level
Red warning, level 3: continuous repetitive chime, flashing red MASTER WARN, and red LAND ASAP
Sets it off
The DC ESS and AC ESS busbars supplied by the batteries
On the batteries
Battery 2 supplies the DC ESS BUS; battery 1 the AC ESS BUS above 50 kt, through the static inverter; the AC and DC SHED ESS buses are shed
The action
EMER ELEC PWR to MAN ON: the RAT extends and the emergency generator takes the essential buses
With it
ELEC EMER CONFIG, red too: AC 1 and AC 2 are not supplied either
Displays in flight
In the emergency configuration the FCTM gives only PFD 1 and, of the ECAM displays, only the E/WD

Sources FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-10 AUDIO INDICATORS / FCOM PRO-ABN-ELEC ELEC / FCTM AOP-30-10 LAND ASAP DEFINITION / FCOM PRO-ABN-ELEC ELEC ESS BUSES ON BAT / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL (CONT'D) / FCOM PRO-ABN-ELEC ELEC EMER CONFIG / FCTM PR-AEP-ELEC GENERAL GUIDELINES

What sets the warning off?

The warning triggers when the DC ESS and AC ESS busbars are supplied by the batteries. Normally they are not: AC BUS 1 supplies the AC ESS BUS, and TR 1 the DC ESS BUS. With both AC buses lost above 100 kt, the RAT extends and the emergency generator takes them over.

The FCOM gives two cases where it cannot. If the RAT stalls, or on the ground below 100 kt, the emergency generator has nothing to drive it, and the emergency network transfers to the batteries and the static inverter by itself. The FCTM places the stall below 125 kt.

The ECAM Trainer's scenario is another way to get there: both engine generators lost in the cruise, the APU not running, and the RAT not extending by itself. The procedure opens with the remark that the AC ESS BUS is supplied via the static inverter; its MIN RAT SPEED 140 KT line is displayed only if the RAT is extended.

Sources FCOM PRO-ABN-ELEC ELEC ESS BUSES ON BAT / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCTM PR-AEP-ELEC TECHNICAL BACKGROUND / FCOM PRO-ABN-ELEC ELEC / FCOM DSC-24-20 OVERHEAD PANEL (CONT'D)

The essential buses on the batteries

The essential buses on the batteriesAC BUS 1 and AC BUS 2 lost, and the emergency generator not supplying. Battery 1 feeds the static inverter, which supplies the AC ESS BUS. Battery 2 supplies the DC ESS BUS. The AC SHED ESS and DC SHED ESS buses are shed. ELEC ESS BUSES ON BAT comes on in red. EMER GENnot supplyingBAT 1BAT 2STAT INV1 KVADC ESS BUSDC SHED ESS shedAC ESS BUSAC SHED ESS shedELEC ESS BUSES ON BATred warning
No AC bus and no emergency generator: battery 2 holds the DC ESS BUS, battery 1 the AC ESS BUS through the static inverter. The shed buses go, and the warning comes on.

What does the crew see and hear?

A red warning is the ECAM's highest level: the continuous repetitive chime, MASTER WARN flashing red and the warning message in red on the E/WD.

On the EMER ELEC PWR panel the red RAT & EMER GEN FAULT light comes on: the emergency generator is not supplying power while AC BUS 1 and AC BUS 2 are not powered.

In the emergency configuration the FCTM gives PFD 1 as the only PFD available and the E/WD as the only ECAM display. With the lower display lost, the FCOM gives a way to see a system page or STATUS on the upper display: push and hold its key, for 3 min at most.

Sources FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-10 AUDIO INDICATORS / FCOM DSC-24-20 OVERHEAD PANEL (CONT'D) / FCOM DSC-31-05-60 FAILURE OF LOWER ECAM DU (OR CTL/BRIGHTNESS KNOB TURNED TO OFF) / FCTM PR-AEP-ELEC GENERAL GUIDELINES

Live aircraft

The moment the warning comes on

The cruise at FL350, both engine generators on line, the APU not running. Press the button to lose both generators with the RAT's automatic extension failed, then look at the E/WD, the schematic and the EMER ELEC PWR panel.

The E/WD as the live aircraft starts, drawn by the platform's systems model
The system's schematic as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model

The alert Lose both generators, no RAT

The E/WD drawn here is the upper display, the only ECAM display the FCTM gives for the emergency configuration. It shows ELEC ESS BUSES ON BAT in red with EMER ELEC PWR MAN ON, then ELEC EMER CONFIG with its own procedure, and red LAND ASAP on the right. MIN RAT SPEED is not shown, the RAT not being extended. The FCOM gives no order for the two warnings; the ECAM Trainer shows ESS BUSES ON BAT first.

The schematic shows the static inverter on the AC ESS BUS, battery 2 on the DC ESS BUS and both shed buses lost; on the panel, the RAT & EMER GEN FAULT light is red. The SD is not drawn: the lower display is lost. Working the procedure is what the ECAM Trainer does with you.

Sources FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC ELEC EMER CONFIG / FCTM PR-AEP-ELEC GENERAL GUIDELINES / FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 OVERHEAD PANEL (CONT'D)

Work this failure in the ECAM Trainer

What does MAN ON do?

MAN ON is the guarded pushbutton on the EMER ELEC PWR panel. At AUTO, the RAT extends and the blue system drives the emergency generator when both AC buses are unpowered above 100 kt. Pressed, it selects the RAT's extension by hand, and the generator couples 3 s after the RAT starts to supply it.

The FCOM's explanation of the procedure's line is short: the essential buses are then supplied by the emergency generator. The RAT itself can be stowed only on the ground.

Sources FCOM DSC-24-20 OVERHEAD PANEL (CONT'D) / FCOM PRO-ABN-ELEC ELEC / FCOM DSC-29-10-20 RAM AIR TURBINE (RAT)

Live aircraft

Press MAN ON

Both generators lost, the RAT still stowed, the essential buses on the batteries. Predict first, then lift the guard and press MAN ON.

The system's schematic as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
  1. Predict The RAT extends. What happens to the essential buses?

    Try it Lift the guard and press MAN ON.

    The RAT drives blue, blue drives the emergency generator, and the generator takes the AC ESS BUS, and the DC ESS BUS through the ESS TR. The static inverter stops, the shed buses are supplied again, and the RAT & EMER GEN FAULT light goes out.

    The live aircraft couples at once; on the aircraft the coupling comes 3 s after the RAT supplies the generator. The aircraft is now in the configuration of ELEC EMER CONFIG, with the RAT out.

    Sources FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL (CONT'D) / FCOM DSC-24-10-20 AC GENERATORS / FCOM PRO-ABN-ELEC ELEC EMER CONFIG

What do the batteries keep?

Two batteries of 23 Ah each are permanently connected to the two hot buses. With AC BUS 1 and 2 not energised and the emergency generator not supplying, battery 1 supplies the AC STAT INV BUS and, above 50 kt, the AC ESS BUS, and battery 2 the DC ESS BUS.

The static inverter turns battery 1's DC into 1 KVA of single-phase 115 V 400 Hz AC for part of the AC ESS BUS. Above 50 kt it comes on by itself whenever only the batteries are supplying, whatever the positions of the BAT 1 and BAT 2 pushbuttons; below 50 kt, only if both are on.

The QRH carries the full ELEC EMER CONFIG SYS REMAINING list, which this page does not reproduce. The FCTM names FAC 1 and FMGC 1 among the additional loads lost on the batteries.

Sources FCOM DSC-24-10-20 DC GENERATION / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-20 AC GENERATORS / FCTM PR-AEP-ELEC GENERAL GUIDELINES / FCTM PR-AEP-ELEC REMAINING SYSTEMS

Batteries, then the emergency generator

Batteries, then the emergency generatorTwo columns. On the batteries: BAT 1 through the static inverter to the AC ESS BUS, BAT 2 to the DC ESS BUS, shed buses lost, and FAC 1 and FMGC 1 among the loads lost. After MAN ON: the RAT and blue drive the emergency generator, which supplies the AC ESS BUS and, through the ESS TR, the DC ESS BUS, with the shed buses back. ON THE BATTERIESAFTER MAN ONAC ESS: STAT INVfrom BAT 1DC ESS: BAT 2SHED BUSES LOSTFAC 1, FMGC 1 lostAC ESS: EMER GENRAT, blueDC ESS: ESS TRSHED BUSES BACK
On the batteries the static inverter carries part of the AC ESS BUS and battery 2 the DC ESS BUS. After MAN ON the emergency generator carries both, through the ESS TR for DC.

What follows the warning?

ELEC EMER CONFIG triggers when the AC 1 and AC 2 busbars are not supplied, which is the case here before and after MAN ON. Its procedure tries to win a main generator back and carries its own EMER ELEC PWR MAN ON, for an emergency generator not in line; here the generator is already on line.

The FCTM's guidance for the emergency configuration applies: the left-hand seat pilot flies on PFD 1, a safe flight path first and the ECAM actions after, a MAYDAY, and an approach at no less than 140 kt to keep the emergency generator supplying.

Sources FCOM PRO-ABN-ELEC ELEC EMER CONFIG / FCOM PRO-ABN-ELEC ELEC / FCTM PR-AEP-ELEC GENERAL GUIDELINES

What happens on the ground and below 50 kt?

Speed decides what the batteries carry. On the ground below 100 kt the DC BAT BUS is connected to the batteries automatically, and the emergency generator has nothing to drive it. Below 50 kt the AC ESS BUS is shed automatically, leading to the loss of every display unit.

The FCTM says the same of the landing in the emergency configuration: approaching 50 kt during the roll, all display units are lost.

Sources FCOM DSC-24-10-30-30 EMERGENCY GENERATION AFTER LOSS OF ALL MAIN GENERATORS / FCTM PR-AEP-ELEC GENERAL GUIDELINES

What is lost afterwards?

The FCOM prints no STATUS for ELEC ESS BUSES ON BAT: its page gives the triggering condition, the flight phase inhibition and the procedure, which ends with EMER ELEC PWR MAN ON. This page therefore draws none.

ELEC EMER CONFIG, which triggers when the AC 1 and AC 2 busbars are not supplied, has a STATUS of its own in the FCOM, in four versions for different aircraft, with MIN RAT SPEED 140 KT and MAX SPEED 320 KT among its limitations. Its explainer shows it.

Sources FCOM PRO-ABN-ELEC ELEC ESS BUSES ON BAT / FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC ELEC EMER CONFIG / FCOM PRO-ABN-ELEC

A319ceo, A320ceo, A320neo, A321neo: what differs?

A319ceo, A320ceoA320neo, A321neo
The warning and its procedureThe same in every versionThe same in every version
Engines, and the FADEC's own power sourceCFM56-5B; its FADEC has a magnetic alternator for an internal power sourceLEAP-1A; its FADEC has a magnetic alternator for an internal power source

Sources FCOM PRO-ABN-ELEC ELEC ESS BUSES ON BAT / FCOM PRO-ABN-ELEC ELEC / FCOM DSC-70-20 GENERAL / FCOM DSC-70-05 OVERVIEW / FCOM DSC-70-05

In the ECAM Trainer · A320 Knowledge+

Work ELEC ESS BUSES ON BAT as a crew

Read and do each line against the FCOM, with the E/WD, the SD page and the overhead following your hands, the PF and PM calls, and a debrief that says what you missed.

Work this failure in the ECAM Trainer

Go further

Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The E/WD, the STATUS and the live aircraft are the platform's own ECAM and systems model, the same the ECAM Trainer and the flight deck run. This page explains the procedure; it is not the procedure. Aircraft differ by type, engine and options: your aircraft's FCOM, your QRH and your operator's procedures always come first. How we write and check these pages.

Work it as a crew

Every ECAM procedure, line by line, against the FCOM.

The ECAM Trainer works 108 scenarios with the E/WD, the SD page and the overhead following your hands. Start free today, or open everything with A320 Knowledge+.

For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.