Amber caution · ECAM procedure · free to read

ELEC IDG 1 DISCONNECTED

An amber caution with no action under it. Here is how an IDG comes to be disconnected, by the crew or by itself, that it stays that way for the rest of the flight, in which flight phases the FCOM lets the caution through, and what takes over from generator 1, with the live aircraft at the caution on the ground, both engines running, in the one flight phase where every version of the FCOM lets it through.

Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy

The answer first

What ELEC IDG 1 DISCONNECTED means

ELEC IDG 1 DISCONNECTED is an amber caution: the integrated drive through which engine 1 turns generator 1 is disconnected, either by the crew's guarded IDG 1 pushbutton or by itself, thermally, at 200 °C. Generator 1 is lost with it, and only maintenance personnel can reconnect the IDG.

The FCOM gives no action for it, only crew awareness and STATUS: CAT 3 SINGLE ONLY, with GEN 1 and CAT 3 DUAL inoperative. Its flight phase graphic inhibits the caution in flight: it lets it through only on the ground, from the first engine start to takeoff power, on some aircraft to 80 kt. The E/WD drawn here follows the ECAM Trainer's scenario, in the cruise, where the FCOM inhibits it.

Sources FCOM PRO-ABN-ELEC ELEC IDG 1(2) DISCONNECTED / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-20 OVERHEAD PANEL / FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC ABNORMAL AND EMERGENCY PROCEDURES / FCOM DSC-31-15 FLIGHT PHASES

The E/WD at the moment ELEC IDG 1 DISCONNECTED triggers, drawn by the platform's ECAM engine: the amber caution title and the lines it shows
The E/WD at the alertAs the ECAM Trainer draws it: in the cruise at FL350. On the aircraft the FCOM inhibits this caution in the cruise, so this is the title as the trainer draws it, with no line under it, not the moment the crew would see it.

At a glance

Level
Amber caution; the FCOM's alert unit does not give its level
Sets it off
IDG 1 is disconnected: by the crew's guarded IDG 1 pushbutton, or by itself when its temperature reaches 200 °C
When it shows
Inhibited in every flight phase but the one from the first engine start to takeoff power; on some aircraft, also to 80 kt
Lights
IDG and DISC in amber at IDG 1 on the ELEC page; the IDG 1 FAULT light off once the IDG is disconnected
For good
Only maintenance personnel can reconnect the IDG
STATUS
CAT 3 SINGLE ONLY; GEN 1 and CAT 3 DUAL inoperative, and MAIN GALLEY only if the APU GEN is not online

Sources FCOM PRO-ABN-ELEC ELEC IDG 1(2) DISCONNECTED / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-24-20 OVERHEAD PANEL / FCOM PRO-ABN-ELEC ELEC / FCOM DSC-31-15 FLIGHT PHASES / FCOM DSC-24-20 ECAM ELEC PAGE / FCOM PRO-ABN-ELEC ABNORMAL AND EMERGENCY PROCEDURES

What sets the caution off?

The alert triggers when IDG 1 is disconnected. The FCOM describes two ways it happens: the crew presses the guarded IDG 1 pushbutton, which disconnects the IDG from its driveshaft, or the IDG disconnects itself thermally when its temperature reaches 200 °C.

The ELEC page shows the IDG's oil outlet temperature. It pulses as an advisory above 147 °C and up to 180 °C, and turns amber above 180 °C, where ELEC IDG 1 OIL OVHT comes on and FAULT lights in the IDG 1 pushbutton. The FCOM does not say which temperature its 200 °C for the thermal disconnection refers to.

Either way generator 1 has lost its drive. On the ELEC page the IDG legend at IDG 1 turns amber and DISC shows in amber, and the IDG 1 FAULT light goes out once the IDG is disconnected. For a disconnection by hand, the OIL LO PR and OIL OVHT procedure has the crew hold the pushbutton until GEN 1's FAULT light comes on.

Sources FCOM PRO-ABN-ELEC ELEC IDG 1(2) DISCONNECTED / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 ECAM ELEC PAGE / FCOM PRO-ABN-ELEC ELEC IDG 1(2) OIL LO PR/OVHT / FCOM PRO-ABN-ELEC ELEC

Two ways to a disconnected IDG

Two ways to a disconnected IDGTwo inputs lead to IDG 1 disconnected: the crew pressing the guarded IDG 1 pushbutton, which the OIL LO PR and OIL OVHT cautions (for the overheat, oil outlet above 180 °C) call for, and an automatic thermal disconnection at 200 °C. With IDG 1 disconnected, GEN 1 is lost, the caution ELEC IDG 1 DISCONNECTED comes up in amber, and the ELEC page shows IDG 1 amber with DISC. IDG 1 PBpressed by the crewOIL > 180 °Camber, OIL OVHT200 °Cthermal disconnectionIDG 1disconnectedGEN 1lostELEC IDG 1 DISCONNECTEDE/WD, amberIDG 1 AMBERDISC, ELEC page
The crew's guarded pushbutton, the one line of the OIL LO PR and OIL OVHT cautions, or a temperature of 200 °C disconnects IDG 1 from its driveshaft. Generator 1 is lost with it, until maintenance reconnects the IDG.

What does the crew see?

An amber caution on the E/WD; the FCOM's procedure is crew awareness, with no action. The FCOM's alert unit does not state its level: a level 2 caution comes with a single chime and MASTER CAUT, a level 1 caution with neither and generally without procedure. For a caution, the SD calls up the relevant system page by itself, except in some cases, as the FCOM's table notes.

On the ELEC page the IDG legend at IDG 1 and DISC are amber, and with one generator operating in flight GALLEY SHED shows. On the ELEC panel the IDG 1 FAULT light is out, since it goes off once the IDG is disconnected.

Sources FCOM PRO-ABN-ELEC ELEC IDG 1(2) DISCONNECTED / FCOM PRO-ABN-ELEC ABNORMAL AND EMERGENCY PROCEDURES / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-20 SYSTEM PAGES / FCOM DSC-24-20 ECAM ELEC PAGE / FCOM DSC-24-20 OVERHEAD PANEL

Live aircraft

The moment the caution comes on

On the ground before takeoff, both engines running and both engine generators on line, the APU not running and no external power. Press the button to disconnect IDG 1, as a thermal disconnection would, then look at the E/WD, the ELEC page, the ELEC panel and the schematic.

The E/WD as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
The system's schematic as the live aircraft starts, drawn by the platform's systems model

The alert Disconnect IDG 1

The E/WD, as the ECAM Trainer draws it, shows ELEC IDG 1 DISCONNECTED in amber, its title alone. GEN 1 is off line and, with the APU not running, GEN 2 supplies AC BUS 1 through the bus tie; the ELEC page shows IDG 1 amber with DISC, and GALLEY SHED: on the ground the main galley is shed when only one engine generator is operating and neither the APU GEN nor external power supplies.

The aircraft here is on the ground with both engines running, before takeoff power: flight phase 2, the one phase in which both of the FCOM's versions let this caution through, as the next question explains.

Sources FCOM PRO-ABN-ELEC ELEC IDG 1(2) DISCONNECTED / FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 ECAM ELEC PAGE / FCOM PRO-ABN-ELEC ELEC / FCOM DSC-31-15 FLIGHT PHASES

Work this failure in the ECAM Trainer

When does the ECAM show it?

The FWC divides a flight into ten phases and inhibits some warnings and cautions in some of them, to avoid alerting the pilots unnecessarily at times of high workload. A failure in an inhibited phase appears once the aircraft enters a phase where it is not inhibited, and stays as long as the failure is present.

For this caution the FCOM prints two versions, each for its own aircraft, with the same trigger. One lets it through only in phase 2, from the first engine start to takeoff power; the other in phases 2 and 3, up to 80 kt on the takeoff roll. Both inhibit it in every phase in the air, the cruise among them.

ELEC GEN 1 FAULT, whose trigger includes a line contactor open with the GEN 1 pushbutton ON, is not inhibited in the cruise. The FCOM does not say whether ELEC GEN 1 FAULT comes on after an IDG disconnection, nor which title, if any, the E/WD shows after one in flight.

Sources FCOM DSC-31-15 FLIGHT PHASES / FCOM PRO-ABN-ELEC ELEC IDG 1(2) DISCONNECTED / FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC ELEC GEN 1(2) FAULT / FCOM DSC-24-20 OVERHEAD PANEL

Why is there nothing to do?

The FCOM prints no action for the caution, only crew awareness and then STATUS, and gives no reason. What it does say: the disconnection is already done, by the crew or by the IDG itself, and only maintenance personnel can reconnect the IDG, so generator 1 stays lost for the flight.

The FCTM asks the flight crew to restrict the reset of systems to those listed in the FCOM or the QRH, and this procedure lists none.

For ELEC IDG 1 OIL LO PR or OIL OVHT, the disconnection by hand is that procedure's one line, IDG OFF, and in flight the FCTM calls for a crosscheck before any action on a guarded control. The FCOM sets the conditions: the engine running or windmilling, at or above idle if it is running, the pushbutton held until the GEN FAULT light comes on and never for more than 3 s.

Sources FCOM DSC-24-20 OVERHEAD PANEL / FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC ABNORMAL AND EMERGENCY PROCEDURES / FCTM AOP-30-20 GENERAL

What takes over from generator 1?

The system replaces the failed generator by itself, with the APU GEN if available, otherwise with GEN 2. With the APU not running, GEN 2 supplies both AC buses through the bus tie; one engine generator can supply the entire network except the DC BUS Entertainment, where fitted.

In flight with only one generator operating, the main galley is shed and GALLEY SHED shows on the ELEC page. The FCOM's STATUS note says that, if available, the APU may be started and the APU GEN used.

Sources FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM DSC-24-10-30-10 GENERAL / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 ECAM ELEC PAGE / FCOM PRO-ABN-ELEC ABNORMAL AND EMERGENCY PROCEDURES

Live aircraft

Put the APU GEN on line

IDG 1 is disconnected and GEN 2 carries both sides. The APU is running, its APU GEN pushbutton still at OFF. Predict first, then press it and watch the ELEC page.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
  1. Predict The APU GEN comes on line. Which AC buses does it take?

    Try it Set APU GEN to ON.

    The APU GEN takes AC BUS 1, the side GEN 1 has lost, and GEN 2 keeps AC BUS 2: an engine generator that is operating has priority over the APU GEN. With two generators operating, GALLEY SHED goes from the ELEC page.

    On STATUS, MAIN GALLEY is listed as inoperative only if the APU GEN is not online. GEN 1 stays on the list whatever the APU GEN does: the FCOM lists it without condition.

    Sources FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM DSC-24-10-30-10 GENERAL / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 ECAM ELEC PAGE / FCOM PRO-ABN-ELEC ABNORMAL AND EMERGENCY PROCEDURES

What is lost afterwards?

The STATUS page after ELEC IDG 1 DISCONNECTED, drawn by the platform's ECAM engine
STATUSOnce the crew has cleared the alerts, as our ECAM draws it.

STATUS is the aircraft's operational summary. For this caution it shows CAT 3 SINGLE ONLY, and under INOP SYS, in amber: MAIN GALLEY, GEN 1 and CAT 3 DUAL. A footnote limits MAIN GALLEY: only if the APU GEN is not online.

The FCOM adds a note: if available, the APU may be started, and the APU GEN used. The STATUS above shows CAT 3 SINGLE ONLY and the three INOP SYS lines, as the FCOM prints them.

Sources FCOM PRO-ABN-ELEC ABNORMAL AND EMERGENCY PROCEDURES / FCOM PRO-ABN-ELEC ELEC / FCOM DSC-31-20 STATUS PAGE

A319ceo, A320ceo, A320neo, A321neo: what differs?

A319ceo, A320ceoA320neo, A321neo
The caution's triggerThe same in every versionThe same in every version
STATUSNot given by type: two versions, each CAT 3 SINGLE ONLY; INOP SYS: MAIN GALLEY (only if APU GEN is not online), GEN 1, CAT 3 DUAL; in one, the MAIN GALLEY footnote adds that all the galleys are then shedNot given by type: two versions, each CAT 3 SINGLE ONLY; INOP SYS: MAIN GALLEY (only if APU GEN is not online), GEN 1, CAT 3 DUAL; in one, the MAIN GALLEY footnote adds that all the galleys are then shed

The caution's two versions in the FCOM go by lists of aircraft, not by type: the trigger reads the same, and the flight phases differ only in phase 3. Its STATUS likewise comes in two versions, each for its own aircraft.

Sources FCOM PRO-ABN-ELEC ELEC IDG 1(2) DISCONNECTED / FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC ABNORMAL AND EMERGENCY PROCEDURES

In the ECAM Trainer · A320 Knowledge+

Work ELEC IDG 1 DISCONNECTED as a crew

Read and do each line against the FCOM, with the E/WD, the SD page and the overhead following your hands, the PF and PM calls, and a debrief that says what you missed.

Work this failure in the ECAM Trainer

Go further

Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The E/WD, the STATUS and the live aircraft are the platform's own ECAM and systems model, the same the ECAM Trainer and the flight deck run. This page explains the procedure; it is not the procedure. Aircraft differ by type, engine and options: your aircraft's FCOM, your QRH and your operator's procedures always come first. How we write and check these pages.

Work it as a crew

Every ECAM procedure, line by line, against the FCOM.

The ECAM Trainer works 108 scenarios with the E/WD, the SD page and the overhead following your hands. Start free today, or open everything with A320 Knowledge+.

For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.