Amber caution · ECAM procedure · free to read

ELEC GEN 1 FAULT

An amber caution with a reset in it. Here is what takes a generator off line, what the network does about it without being asked, what the OFF then ON actually resets, and what the loss means on a CAT 3 day, with the live aircraft at the moment the caution comes on.

Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy

The answer first

What ELEC GEN 1 FAULT means

ELEC GEN 1 FAULT is an amber caution: generator 1, which engine 1 drives through an integrated drive, is off line, either because its GCU has tripped it or because its line contactor is open while the GEN 1 pushbutton is ON. AC BUS 1 is not lost: the system replaces the generator by itself, with the APU GEN if it is available, otherwise with GEN 2.

The ECAM asks for one reset, GEN 1 OFF then ON, and OFF if that is unsuccessful. STATUS then lists GEN 1 and CAT 3 DUAL as inoperative and shows CAT 3 SINGLE ONLY.

Sources FCOM PRO-ABN-ELEC ELEC GEN 1(2) FAULT / FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC CAT 3 DUAL

The E/WD at the moment ELEC GEN 1 FAULT triggers, drawn by the platform's ECAM engine: the amber caution title and the lines it shows
The E/WD at the alertAs our ECAM draws it, the moment it triggers: on the ILS at 3 000 ft for a CAT 3 approach.

At a glance

Level
Amber caution; the FCOM's alert unit does not give its level
Sets it off
The GCU trips generator 1, or its line contactor is open with the GEN 1 pushbutton ON
Lights
FAULT, amber, in the GEN 1 pushbutton on the overhead ELEC panel
What takes over
The APU GEN if available, otherwise GEN 2 through the bus tie; with GEN 2 alone, part of the galley load is shed
Procedure
GEN 1 OFF then ON; if unsuccessful, GEN 1 OFF
STATUS
CAT 3 SINGLE ONLY; GEN 1 and CAT 3 DUAL inoperative, and MAIN GALLEY only if the APU GEN is not online

Sources FCOM PRO-ABN-ELEC ELEC GEN 1(2) FAULT / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC CAT 3 DUAL

What sets the caution off?

Each main engine drives its own AC generator through an integrated drive, and each generator has its Generator Control Unit (GCU). The GCU controls the generator's frequency and voltage, and protects the network by controlling the generator line contactor, GLC 1, through which GEN 1 supplies AC BUS 1.

The caution comes on in two cases: the GCU initiates a protection trip, or the line contactor is open with the GEN 1 pushbutton at ON. The same two cases light FAULT in the GEN 1 pushbutton. Selecting the pushbutton OFF also opens the contactor, but the FAULT light does not come on for that.

The FWC does not show the caution in every flight phase. The FCOM's graphic inhibits it before the first engine is started, from 80 kt on the takeoff roll to 1 500 ft, from 800 ft to 80 kt after touchdown, and for 5 min after the second engine is shut down. A failure in an inhibited phase appears once the aircraft enters a phase where it is not inhibited.

Sources FCOM DSC-24-10-20 AC GENERATORS / FCOM DSC-24-10-30-20 IN FLIGHT / FCOM PRO-ABN-ELEC ELEC GEN 1(2) FAULT / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-31-15 FLIGHT PHASES

From a tripped generator to the caution

From a tripped generator to the cautionEngine 1 drives the integrated drive, which turns GEN 1. GEN 1 reaches AC BUS 1 through its line contactor, GLC 1, which the GCU controls. When the GCU trips the generator, or the contactor is open with the GEN 1 pushbutton ON, ELEC GEN 1 FAULT comes on in amber on the E/WD and FAULT lights in the GEN 1 pushbutton. ENGINE 1drivesIDG 1integrated driveGEN 1off lineGLC 1line contactor, openGCU 1protection tripFAULTGEN 1 pbELEC GEN 1 FAULTE/WD, amber
Engine 1 drives GEN 1 through its integrated drive; GEN 1 reaches AC BUS 1 through its line contactor. A GCU trip, or the contactor open with GEN 1 at ON, gives the caution and the FAULT light.

What does the crew see and hear?

An amber caution on the E/WD, with its reset under it. The FCOM's alert unit does not state its level: a level 2 caution comes with a single chime and MASTER CAUT, a level 1 caution with neither and generally without procedure. For a caution, the SD calls up the relevant system page by itself, except in some cases, as the FCOM's table notes.

On the overhead ELEC panel, FAULT lights amber in the GEN 1 pushbutton. On the ELEC page, the network shows which source now supplies AC BUS 1, and with only one generator operating in flight the main galley is shed and GALLEY SHED appears.

Sources FCOM PRO-ABN-ELEC ELEC GEN 1(2) FAULT / FCOM PRO-ABN-ELEC ELEC / FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-20 SYSTEM PAGES / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 ECAM ELEC PAGE

Live aircraft

The moment the caution comes on

The cruise, both engine generators on line, the APU not running. Press the button to fail generator 1, then look at the E/WD, the ELEC page, the ELEC panel and the schematic.

The E/WD as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
The overhead panel as the live aircraft starts, drawn by the platform's systems model
The system's schematic as the live aircraft starts, drawn by the platform's systems model

The alert Fail generator 1

The E/WD shows ELEC GEN 1 FAULT in amber, its first line GEN 1 OFF THEN ON. FAULT lights in the GEN 1 pushbutton on the panel.

Nobody pressed anything, yet AC BUS 1 is still supplied: with the APU not running, GEN 2 has taken it over through the bus tie, and GALLEY SHED shows on the ELEC page. Working the reset is what the ECAM Trainer does with you.

Sources FCOM PRO-ABN-ELEC ELEC / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM DSC-24-20 ECAM ELEC PAGE

Work this failure in the ECAM Trainer

What does OFF then ON actually reset?

GEN 1 OFF de-energises the generator field, opens the line contactor and resets the fault circuit. Back at ON, the field is energised again and the line contactor closes if the electrical parameters are normal.

So the reset gives the generator one more chance to come back on line. If it is unsuccessful, the procedure ends with GEN 1 OFF; the FCOM does not spell out what unsuccessful looks like. For one case the FCOM is explicit: if a differential fault tripped the protection, a reset has no effect after two attempts.

The procedure gives one reset and then OFF, and no more. The FCTM asks the flight crew to restrict the reset of systems to those listed in the FCOM or the QRH.

Sources FCOM DSC-24-20 OVERHEAD PANEL / FCOM PRO-ABN-ELEC ELEC / FCTM AOP-30-20 GENERAL

Which generator takes over, and does the APU help?

The system replaces a failed generator by itself: with the APU GEN if it is available, otherwise with the other engine generator. One engine generator can supply the entire network except the DC BUS Entertainment, where fitted. With GEN 2 alone, part of the galley load and the DC BUS Entertainment are shed automatically: two generators are needed for the DC BUS Entertainment, except on the ground, where the APU GEN or external power is enough.

The APU GEN, driven directly by the APU, produces the same output as an engine generator and can replace either or both of them at any time. The STATUS note says that, if available, the APU may be started and the APU GEN used, and MAIN GALLEY is listed as inoperative only if the APU GEN is not online.

Sources FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM DSC-24-10-30-10 GENERAL / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-10-20 AC GENERATORS / FCOM PRO-ABN-ELEC ELEC

Who supplies AC BUS 1 after the fault

Who supplies AC BUS 1 after the faultGEN 1 is off line. The first replacement is the APU GEN, if available, supplying AC BUS 1 while GEN 2 keeps AC BUS 2. Without it, GEN 2 supplies AC BUS 1 too, through the bus tie, and in flight with one generator the main galley is shed. firstGEN 1off lineAPU GENif availableGEN 2otherwiseAC BUS 1kept suppliedBUS TIEAUTOAC BUS 2GEN 2GALLEY SHEDone generator
GEN 1 is off line. The APU GEN takes AC BUS 1 if it is available; if not, GEN 2 supplies both AC buses through the bus tie, and the main galley is shed.
Live aircraft

Bring the APU GEN on line

Generator 1 has failed and GEN 2 carries both sides. The APU is running, its APU GEN pushbutton still at OFF. Predict first, then press it and watch the ELEC page.

The overhead panel as the live aircraft starts, drawn by the platform's systems model
The SD page as the live aircraft starts, drawn by the platform's systems model
  1. Predict GEN 2 already supplies both AC buses. What happens to AC BUS 1 when the APU GEN comes on?

    Try it Set APU GEN to ON.

    The APU GEN takes over AC BUS 1 and GEN 2 goes back to its own side: an engine generator that is operating has priority over the APU GEN, and the generators cannot be connected in parallel. With two generators operating, GALLEY SHED goes from the ELEC page.

    This is what the STATUS note offers. With the APU GEN online, MAIN GALLEY no longer qualifies for the INOP SYS list, which carries it only if the APU GEN is not online.

    Sources FCOM DSC-24-10-30-30 FAILURE OF ONE ENGINE GENERATOR / FCOM DSC-24-10-30-10 GENERAL / FCOM DSC-24-20 OVERHEAD PANEL / FCOM DSC-24-20 ECAM ELEC PAGE / FCOM PRO-ABN-ELEC ELEC

What does one generator less mean for a CAT 3 approach?

STATUS lists CAT 3 DUAL as inoperative and shows CAT 3 SINGLE ONLY, in green, among its information lines. The FCOM gives the result, not the reason a generator takes CAT 3 DUAL with it.

The FCTM explains the difference. CAT 3 DUAL is fail-operational: after a single failure the autopilot goes on guiding the aircraft, and the automatic landing system operates as a fail-passive one. CAT 3 SINGLE is fail-passive: a single failure leads to the autopilot disconnecting, without a significant out of trim condition or deviation, and the crew then flies manually. Its minimum DH is 50 ft.

For a failure on a low visibility approach, the FCTM's go-around strategy applies: if it occurs above 1 000 ft RA, all ECAM actions, and any DH amendment, should be completed before 1 000 ft RA, otherwise a go-around should be initiated.

Lower down, the caution is inhibited from 800 ft until 80 kt after touchdown; a failure there is shown once the aircraft enters a phase where it is not inhibited.

Sources FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC CAT 3 DUAL / FCOM DSC-31-20 STATUS PAGE / FCTM PR-NP-SOP-190-GUI / FCOM PRO-ABN-ELEC ELEC GEN 1(2) FAULT / FCOM DSC-31-15 FLIGHT PHASES

What is lost afterwards?

The STATUS page after ELEC GEN 1 FAULT, drawn by the platform's ECAM engine
STATUSOnce the crew has cleared the alerts, as our ECAM draws it.

STATUS is the aircraft's operational summary. For ELEC GEN 1 FAULT it shows CAT 3 SINGLE ONLY, and under INOP SYS, in amber: MAIN GALLEY, GEN 1 and CAT 3 DUAL. A footnote limits MAIN GALLEY: only if the APU GEN is not online.

The FCOM adds a note: if available, the APU may be started, and the APU GEN used. The STATUS above shows CAT 3 SINGLE ONLY and the three INOP SYS lines, as the FCOM prints them.

Sources FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC CAT 3 DUAL / FCOM DSC-31-20 STATUS PAGE

A319ceo, A320ceo, A320neo, A321neo: what differs?

A319ceo, A320ceoA320neo, A321neo
The caution and its procedureThe same in every versionThe same in every version
STATUSNot given by type: two versions, each CAT 3 SINGLE ONLY; INOP SYS: MAIN GALLEY (only if APU GEN is not online), GEN 1, CAT 3 DUAL; in one, the MAIN GALLEY footnote adds that all the galleys are then shedNot given by type: two versions, each CAT 3 SINGLE ONLY; INOP SYS: MAIN GALLEY (only if APU GEN is not online), GEN 1, CAT 3 DUAL; in one, the MAIN GALLEY footnote adds that all the galleys are then shed

The FCOM prints the STATUS in two versions, each for its own aircraft. The lines are the same; only one version's footnote to MAIN GALLEY says more.

Sources FCOM PRO-ABN-ELEC ELEC GEN 1(2) FAULT / FCOM PRO-ABN-ELEC ELEC / FCOM PRO-ABN-ELEC CAT 3 DUAL

In the ECAM Trainer · A320 Knowledge+

Work ELEC GEN 1 FAULT as a crew

Read and do each line against the FCOM, with the E/WD, the SD page and the overhead following your hands, the PF and PM calls, and a debrief that says what you missed.

Work this failure in the ECAM Trainer

Go further

Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The E/WD, the STATUS and the live aircraft are the platform's own ECAM and systems model, the same the ECAM Trainer and the flight deck run. This page explains the procedure; it is not the procedure. Aircraft differ by type, engine and options: your aircraft's FCOM, your QRH and your operator's procedures always come first. How we write and check these pages.

Work it as a crew

Every ECAM procedure, line by line, against the FCOM.

The ECAM Trainer works 108 scenarios with the E/WD, the SD page and the overhead following your hands. Start free today, or open everything with A320 Knowledge+.

For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.