- Home
- ECAM procedures
- HYD Y RSVR LO LVL
HYD Y RSVR LO LVL
An amber caution: the yellow system is losing its fluid. Here is what the reservoir level tells the crew, why the PTU is switched off without delay, why the brake accumulator is watched, and what the aircraft lands without, with the live aircraft at the moment the caution comes on.
Written and checked by current A320 pilotschecked against the FCOM on Our editorial policy
What HYD Y RSVR LO LVL means
HYD Y RSVR LO LVL is an amber caution: the yellow reservoir holds less than 3.5 l, so the yellow system is losing its fluid. Each system has its own reservoir and fluid cannot be transferred from one system to another, so green and blue cannot make it up.
The procedure has the crew switch off the PTU first, then the yellow engine pump and the yellow electric pump, and monitor the brake accumulator pressure. The FCTM asks for the PTU off without delay, because a PTU overheat may cost the second system.
Sources FCOM PRO-ABN-HYD HYD Y RSVR LO LVL / FCOM DSC-29-10-10 GENERAL / FCOM PRO-ABN-HYD HYD / FCTM PR-AEP-HYD HYDRAULIC GENERATION PARTICULARITIES

At a glance
- Level
- Amber caution, level 2: single chime and a steady amber MASTER CAUT light
- Sets it off
- Yellow reservoir fluid below 3.5 l; inhibited for the first 15 s of flight phase 5
- Lights
- FAULT on the yellow pump and PTU pushbuttons; the yellow quantity in amber on the HYD page
- Then
- Y ENG 2 PUMP LO PR and Y SYS LO PR; HYD PTU FAULT can follow
- Landing
- Landing distance procedure; no nosewheel steering or reverser 2; flaps slow
Sources FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM PRO-ABN-HYD HYD Y RSVR LO LVL / FCOM DSC-29-20 OVERHEAD PANEL / FCOM DSC-29-20 ECAM HYD PAGE / FCOM PRO-ABN-HYD HYD / FCOM PRO-ABN-HYD HYD PTU FAULT
What sets the caution off?
The HYD page shows each reservoir's fluid quantity in green, and in amber once it goes below the warning level. For yellow that level is 3.5 l, and the caution triggers when the quantity is below it. It is inhibited for the first 15 s of flight phase 5.
On the overhead HYD panel, the ENG 2 PUMP and the YELLOW ELEC PUMP pushbuttons both have a FAULT light that comes on for a low reservoir level, and so does the PTU pushbutton for a low green or yellow level.
The loss shows downstream too. The procedure lists Y ENG 2 PUMP LO PR and, as its associated procedure, Y SYS LO PR; on the HYD page a system's pressure turns amber below 1 450 psi.
Sources FCOM DSC-29-20 ECAM HYD PAGE / FCOM PRO-ABN-HYD HYD Y RSVR LO LVL / FCOM DSC-29-20 OVERHEAD PANEL / FCOM PRO-ABN-HYD HYD
From a leak to the caution
What does the crew see and hear?
An amber caution of level 2 brings the single chime, a steady amber MASTER CAUT light and the amber message on the E/WD, and the SD normally calls up the relevant system page. The FCOM asks for no immediate action at this level, but, time and situation permitting, for such a caution to be considered without delay, to stop the system degrading further.
The title is boxed as a primary failure, and *F/CTL follows as a secondary failure.
Sources FCOM DSC-31-10 WARNING/CAUTION CLASSIFICATION / FCOM DSC-31-15 PRIMARY AND SECONDARY FAILURE / FCOM PRO-ABN-HYD HYD
The moment the caution comes on
A healthy aircraft in the cruise. Press the button to drain the yellow reservoir, then look at the E/WD, the HYD page and the HYD panel.



The alert Drain the yellow reservoir
The E/WD shows HYD Y RSVR LO LVL in amber with its lines: PTU OFF, YELLOW ENG 2 PUMP OFF, BRK Y ACCU PR MONITOR, then Y ENG 2 PUMP LO PR and Y SYS LO PR. The FCOM's YELLOW ELEC PUMP OFF line is not drawn, the pump being off already. HYD PTU FAULT comes up as a caution of its own, its one line PTU OFF.
On the HYD page the yellow quantity and pressure are amber, while green and blue keep their pressure. The PTU does not run, and HYD PTU FAULT reports it: in flight it triggers when the PTU at AUTO does not run with the green or yellow reservoir level low and the green or yellow system pressure low. Working the lines is what the ECAM Trainer does with you.
Sources FCOM PRO-ABN-HYD HYD / FCOM DSC-29-20 ECAM HYD PAGE / FCOM PRO-ABN-HYD HYD PTU FAULT
Why does the PTU go off first?
The PTU joins green and yellow: when their pressures are more than 500 psi apart, either system pressurises the other, and no fluid crosses. At AUTO it is armed and runs by itself.
With a reservoir low level, an overheat or a low air pressure, the FCTM asks for the PTU off as the ECAM requires, to avoid a PTU overheat which may occur two minutes later, and "a PTU overheat may lead to the loss of the second hydraulic circuit." For HYD G(Y) RSVR LO LVL it should go off without delay.
Setting the PTU off closes both its green and its yellow valves, and power transfer stops. Green still has its own pump, driven by engine 1.
HYD PTU FAULT, which can follow this caution, asks for the same PTU OFF if a green or yellow reservoir level is low and system pressure is low.
Sources FCOM DSC-29-10-20 POWER TRANSFER UNIT (PTU) / FCOM DSC-29-20 OVERHEAD PANEL / FCOM DSC-29-10-10 GENERAL / FCTM PR-AEP-HYD HYDRAULIC GENERATION PARTICULARITIES / FCOM DSC-29-10-20 GREEN SYSTEM PUMP / FCOM PRO-ABN-HYD HYD PTU FAULT / FCOM PRO-ABN-HYD HYD
Try the yellow electric pump
The yellow reservoir is below its low level and yellow has lost its pressure. Predict first, then switch the yellow electric pump on and watch the schematic.


-
Predict Yellow has a second pump, driven electrically. Will it bring yellow back?
Try it Switch the YELLOW ELEC PUMP on.
The pump is on but yellow stays without pressure: the HYD page shows the pump in amber, on with yellow at low pressure, and its FAULT light covers a low reservoir level. Each system has its own reservoir, and fluid cannot be transferred from another. The procedure's third line sets the yellow electric pump OFF.
Sources FCOM DSC-29-10-10 GENERAL / FCOM DSC-29-20 OVERHEAD PANEL / FCOM DSC-29-20 ECAM HYD PAGE / FCOM PRO-ABN-HYD HYD
Why watch the brake accumulator?
The normal brakes use green. The alternate system uses yellow, backed up by a hydraulic accumulator, and the parking brake is supplied by yellow or by that accumulator.
The procedure's last action line is BRK Y ACCU PR MONITOR. The FCOM's reason: a pipe rupture could lose the system and the accumulator fluid at the same time, and the loss of the accumulator should then show on the indicator within 10 min. The triple indicator on the centre instrument panel shows the accumulator pressure.
If that happens, normal braking on green is the only remaining braking means, the parking brake should not be used as it is not available, and the chocks should be in place before engine 1 is shut down.
Even without a rupture, STATUS notes that the parking brake may be inoperative after a yellow failure, from a low yellow accumulator pressure.
Sources FCOM DSC-32-30-10 GENERAL / FCOM DSC-32-30-10 / FCOM PRO-ABN-HYD HYD / FCOM DSC-32-30-20 CENTER INSTRUMENT PANEL
What does the aircraft lose with yellow?
STATUS lists as inoperative spoilers 2 and 4, nosewheel steering, reverser 2, the cargo door and yaw damper 2, with CAT 3 DUAL and, where fitted, the steep approach. The flaps are slow.
The flap motors use yellow and green power, and with one hydraulic system inoperative the flaps operate at half speed.
The FCTM sums up a single hydraulic failure: very little effect on handling, but the landing capability drops to CAT 3 SINGLE.
Green keeps the normal brakes and the gear, and unlike the STATUS of a green reservoir low level, the yellow one asks for no gravity extension.
Sources FCOM PRO-ABN-HYD HYD / FCOM DSC-27-30-10 MAIN COMPONENTS / FCTM PR-AEP-HYD DUAL HYDRAULIC FAILURES / FCOM DSC-32-30-10 GENERAL / FCOM DSC-32-10-10 LANDING GEARS AND DOORS OPERATION
What yellow takes, what stays
What is lost afterwards?


STATUS asks for the landing distance procedure, then gives FUEL CONSUMPT INCRSD and FMS PRED UNRELIABLE: the FMS fuel predictions are disregarded and a fuel penalty factor found. FLAPS SLOW and CAT 3 SINGLE follow, then the parking brake note.
INOP SYS lists yellow hydraulics, spoilers 2 and 4, CAT 3 DUAL, nosewheel steering, reverser 2, the cargo door, yaw damper 2 and, where fitted, the steep approach.
Which version applies depends on your aircraft: check your own FCOM.
Sources FCOM PRO-ABN-HYD HYD
A319ceo, A320ceo, A320neo, A321neo: what differs?
| A319ceo, A320ceo | A320neo, A321neo | |
|---|---|---|
| The caution and its procedure | The same in every version | The same in every version |
| STATUS: YAW DAMPER 2 | Listed as inoperative; one version, for a list of aircraft, adds the note "When both engines are running" | The same: listed as inoperative, with the note in one version only |
The FCOM prints two versions of this STATUS for different aircraft. The page draws the first; the second adds that note to YAW DAMPER 2.
Sources FCOM PRO-ABN-HYD HYD Y RSVR LO LVL / FCOM PRO-ABN-HYD HYD / FCOM PRO-ABN-HYD

Work HYD Y RSVR LO LVL as a crew
Read and do each line against the FCOM, with the E/WD, the SD page and the overhead following your hands, the PF and PM calls, and a debrief that says what you missed.
Work this failure in the ECAM TrainerGo further
Written in our own words from the FCOM and the FCTM; each part names the units it rests on. The E/WD, the STATUS and the live aircraft are the platform's own ECAM and systems model, the same the ECAM Trainer and the flight deck run. This page explains the procedure; it is not the procedure. Aircraft differ by type, engine and options: your aircraft's FCOM, your QRH and your operator's procedures always come first. How we write and check these pages.
Every ECAM procedure, line by line, against the FCOM.
The ECAM Trainer works 108 scenarios with the E/WD, the SD page and the overhead following your hands. Start free today, or open everything with A320 Knowledge+.
For study and revision only. Always follow your operator's approved documentation and procedures. A320 Knowledge is independent and not affiliated with Airbus.
Related
- HYD B+Y SYS LO PRA red warning: blue and yellow are lost and green is left alone, still in normal law.
- HYD B ELEC PUMP LO PRAn amber caution that costs a whole system.
- HYD B RSVR LO LVLAn amber caution: the blue system is losing its fluid.
- HYD B RSVR OVHTAn amber caution with one line, and the FCOM's own worked example of the ECAM.
- A320 hydraulic systemThe system guide, with the live aircraft